Read from the publisher's own document for this exact model (Page 2, Mechanical Characteristics, "Frame"). The publisher prints no further test condition for this row; no value was taken from another model.
Printed as "Maximum Power Current (Imp, A) 12.85 12.92 12.99 13.06 13.13 13.20 13.27 13.34" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 2/2026, the EAGLE G6R (JKMxxxN-54HL4-B) table (header "Module Type EAGLE G6R (JKMxxxN-54HL4-B) xxx = 405 410 415 420 425 430 435 440"); the value 13.20 is in the xxx = 430 column, column 6 of 8 columns, which is JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 25, Appendix 2 (Electrical Specifications), EAGLE G6R (JKMxxxN-54HL4-B) table, "Maximum Power Current (Imp, A)" row, xxx = 430 column
Printed as "Short-circuit Current (Isc, A) 13.30 13.37 123.44 13.51 13.58 13.65 13.72 13.80" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 2/2026, the EAGLE G6R (JKMxxxN-54HL4-B) table (header "Module Type EAGLE G6R (JKMxxxN-54HL4-B) xxx = 405 410 415 420 425 430 435 440"); the value 13.65 is in the xxx = 430 column, column 6 of 8 columns, which is JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Printed as "Maximum Power Voltage (Vmp, V) 31.52 31.74 31.95 32.16 32.37 32.58 32.78 32.99" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 2/2026, the EAGLE G6R (JKMxxxN-54HL4-B) table (header "Module Type EAGLE G6R (JKMxxxN-54HL4-B) xxx = 405 410 415 420 425 430 435 440"); the value 32.58 is in the xxx = 430 column, column 6 of 8 columns, which is JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 25, Appendix 2 (Electrical Specifications), EAGLE G6R (JKMxxxN-54HL4-B) table, "Maximum Power Voltage (Vmp, V)" row, xxx = 430 column
Printed as "Open-circuit Voltage (Voc, V) 38.10 38.32 38.53 38.74 38.95 39.16 39.36 39.57" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 2/2026, the EAGLE G6R (JKMxxxN-54HL4-B) table (header "Module Type EAGLE G6R (JKMxxxN-54HL4-B) xxx = 405 410 415 420 425 430 435 440"); the value 39.16 is in the xxx = 430 column, column 6 of 8 columns, which is JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Jinko modules can be grounded using bolts.; Attach the equipment grounding conductor to the module frame using the hole and hardware.; ground 6-12AWG wire; It is recommended that the applied torque is 1.7~2.0 ft-lbs (2.3~2.8 N*m).
Printed as "Jinko modules can be grounded using bolts. Attach the equipment grounding conductor to the module frame using the hole and hardware." in section 3 (Wiring and Connection) of JinkoSolar's User Manual (UL61730), Edition 2/2026, followed by "a stainless- steel bolt is used between the ground 6-12AWG wire and module frame" and the recommended torque quoted here. Table 11 lists the grounding hardware: stainless steel M4 bolt, spring washer, nut, star washer and plain washers. Third-party grounding devices only if UL2703 certified with Jinko modules.
Where: PDF page 18, section 3 Wiring and Connection, item 5 and the grounding hardware table
Printed as "Weight 21.0kg (46.3lbs)" in JinkoSolar EAGLE G6R 420-440 W (JKM420-440N-54HL4-B) datasheet, Mechanical characteristics, Weight row. Revised on 1 October 2026: The manufacturer datasheet for the JKM420-440N-54HL4-B family prints a weight of 21.0 kg (46.3 lbs); the stored 22 kg came from a seller page.
3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass
Printed as "Front Glass 3.2mm, Anti-Reflection Coating High Transmission, Low Iron, Tempered Glass" in JinkoSolar's EAGLE G6R 420-440 W (JKM420-440N-54HL4-B) datasheet, captured on September 28, 2026.
Where: Page 2, Mechanical Characteristics, Front Glass row
Printed as "Torque 16-20 Nm (M8 bolt)" in Table 6, Minimum values for clamp dimensions, contact area and torque, of JinkoSolar's User Manual (UL61730), Edition 2/2026; the clamp torque for an M8 bolt. Table 3 on PDF page 11 prints the same 16-20 Nm reference torque for M8 bolts in 14×9 mounting holes.
Where: PDF page 13, Table 6 (Minimum values for clamp dimensions, contact area and torque) in section 2.3.2, Fixed Installation-Mounting with Clamps
Read from the publisher's own document for this exact model (Page 2, Mechanical Characteristics, "Junction Box"). The publisher prints no further test condition for this row; no value was taken from another model.
W 1,134 × L 1,722 × D 35 mm / W 44.65 × L 67.8 × D 1.4 in converted
Printed as "Dimensions 1722 × 1134 × 35mm (67.79 × 44.65 × 1.38 inch)" in JinkoSolar EAGLE G6R 420-440 W (JKM420-440N-54HL4-B) datasheet, JinkoSolar EAGLE G6R 420-440 W US datasheet (JKM420-440N-54HL4-B-R-F2-US), page 2, Mechanical Characteristics, "Dimensions" row, single value printed for every model in the table. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Where: JinkoSolar EAGLE G6R 420-440 W US datasheet (JKM420-440N-54HL4-B-R-F2-US), page 2, Mechanical Characteristics, "Dimensions" row, single value printed for every model in the table
Printed as "Maximum Power at STC (Pmax, Wp) 405 410 415 420 425 430 435 440" in Appendix 2 (Electrical Specifications) of JinkoSolar's User Manual (UL61730), Edition 2/2026, the EAGLE G6R (JKMxxxN-54HL4-B) table (header "Module Type EAGLE G6R (JKMxxxN-54HL4-B) xxx = 405 410 415 420 425 430 435 440"); the value 430 is in the xxx = 430 column, column 6 of 8 columns, which is JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 25, Appendix 2 (Electrical Specifications), EAGLE G6R (JKMxxxN-54HL4-B) table, "Maximum Power at STC (Pmax, Wp)" row, xxx = 430 column
Printed as "Maximum Series Fuse Rating 25A" in JinkoSolar EAGLE G6R 420-440 W (JKM420-440N-54HL4-B) datasheet, JinkoSolar EAGLE G6R 420-440 W US datasheet (JKM420-440N-54HL4-B-R-F2-US), page 2, Maximum Ratings, "Maximum Series Fuse Rating" row, single value printed for every model in the table. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Where: JinkoSolar EAGLE G6R 420-440 W US datasheet (JKM420-440N-54HL4-B-R-F2-US), page 2, Maximum Ratings, "Maximum Series Fuse Rating" row, single value printed for every model in the table
Bolts (Table 4): EAGLE G6R (JKMxxxN-54HL4-B) Four inner holes 860 +5400/-2400; Long side clamping (Table 7): EAGLE G6R (JKMxxxN-54HL4-B) 1722*1134*35 L=A/5±50 +5400 / -2400; Short side clamping (Table 8): EAGLE G6R (JKMxxxN-54HL4-B) 1722*1134*35 S=100~240 +1600/- 1600; Long side and short side clamping (Table 9): EAGLE G6R (JKMxxxN-54HL4-B) 1722*1134*35 100~240 A/4±50 +2400/- 2400
Printed as "EAGLE G6R (JKMxxxN-54HL4-B) Four inner holes 860 +5400/-2400" in JinkoSolar's User Manual (UL61730), Edition 2/2026, with the other rows quoted here from the same mounting tables (the value lists each method with its table heading and the row for this series as printed). Loads are maximum test loads in Pa. The short-side and long/short-side methods are, in Jinko's words, "based on Jinko’s internal results" and not evaluated by UL. L and S are the clamp positions measured from the module edge; A is the length of the long side.
Where: PDF page 12 (Table 4), PDF page 14 (Table 7), PDF page 15 (Table 8) and PDF page 16 (Table 9)
The bending radius of cables shall be no less than 4 x the cable OD (outer diameter)
Printed as "The bending radius of cables shall be no less than 4 x the cable OD (outer diameter)" in the wire management instructions of JinkoSolar's User Manual (UL61730), Edition 2/2026, a series-wide instruction for the modules the manual covers.
Where: PDF page 20, section 3 Wiring and Connection, item 14 (wire management)
Printed as "Maximum series overcurrent protective device rating 25A" for the whole EAGLE G6R (JKMxxxN-54HL4-B) table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 2/2026, one figure for every power class in it, including JKM430N-54HL4-B.
Where: PDF page 25, Appendix 2, EAGLE G6R (JKMxxxN-54HL4-B) table, "Maximum series overcurrent protective device rating" row
Printed as "Maximum system Voltage 1000VDC" for the whole EAGLE G6R (JKMxxxN-54HL4-B) table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 2/2026, one figure for every power class in it, including JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Where: PDF page 25, Appendix 2, EAGLE G6R (JKMxxxN-54HL4-B) table, "Maximum system Voltage" row
Printed as "Module Efficiency STC (%) 21.51% 21.76% 22.02% 22.28% 22.53%" in JinkoSolar EAGLE G6R 420-440 W (JKM420-440N-54HL4-B) datasheet, JinkoSolar EAGLE G6R 420-440 W US datasheet (JKM420-440N-54HL4-B-R-F2-US), page 2, Electrical Characteristics, "Module Efficiency STC (%)" row, JKM430N-54HL4-B column. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Where: JinkoSolar EAGLE G6R 420-440 W US datasheet (JKM420-440N-54HL4-B-R-F2-US), page 2, Electrical Characteristics, "Module Efficiency STC (%)" row, JKM430N-54HL4-B column
Printed as "Temperature coefficients 0.045% for Isc -0.25% for Voc -0.29% for Pmax" for the whole EAGLE G6R (JKMxxxN-54HL4-B) table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 2/2026; the Pmax figure is -0.29%, a temperature coefficient (per °C) for every power class in the table, including JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Printed as "Temperature coefficients 0.045% for Isc -0.25% for Voc -0.29% for Pmax" for the whole EAGLE G6R (JKMxxxN-54HL4-B) table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 2/2026; the Isc figure is 0.045%, a temperature coefficient (per °C) for every power class in the table, including JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
Printed as "Temperature coefficients 0.045% for Isc -0.25% for Voc -0.29% for Pmax" for the whole EAGLE G6R (JKMxxxN-54HL4-B) table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 2/2026; the Voc figure is -0.25%, a temperature coefficient (per °C) for every power class in the table, including JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: First-year degradation needed.
Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.
Printed as "Module Efficiency STC (%) 21.51% 21.76% 22.02% 22.28% 22.53%" in JinkoSolar EAGLE G6R 420-440 W (JKM420-440N-54HL4-B) datasheet, JinkoSolar EAGLE G6R 420-440 W US datasheet (JKM420-440N-54HL4-B-R-F2-US), page 2, Electrical Characteristics, "Module Efficiency STC (%)" row, JKM430N-54HL4-B column. Revised on 1 October 2026: The datasheet prints this value on page 2 for this model, not on page 1 as the old reference said.
Power temperature coefficient-0.29 %/°C12.1 / 16.0
0.29 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air
Printed as "Temperature coefficients 0.045% for Isc -0.25% for Voc -0.29% for Pmax" for the whole EAGLE G6R (JKMxxxN-54HL4-B) table in Appendix 2 of JinkoSolar's User Manual (UL61730), Edition 2/2026; the Pmax figure is -0.29%, a temperature coefficient (per °C) for every power class in the table, including JKM430N-54HL4-B. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to JinkoSolar (jinkosolar.us), which stays listed as an additional source.
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[4]
Scope
equipment listing
Covered models
JKM430N-54HL4-B
Limitations
Model JKM430N-54HL4-B listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Jinko Solar Co., Ltd, as "JKM430N-54HL4-B", CEC listing date 2022-12-12. This is an equipment listing, not UL certification or complete-system approval.
Location: Cover page (edition) and Appendix 1, Applicable Products (scope)
Retrieved Oct 1, 2026
JinkoSolar's own installation manual for its U.S. (UL 61730) photovoltaic modules, captured 1 October 2026 from jinkosolar.us, printed as Edition 2/2026 on the cover; its Appendix 1 (Applicable Products) names EAGLE G6R (JKMxxxN-54HL4-B, xxx = 405~440), EAGLE G6B (JKMxxxN-72HL4-BDV, xxx = 555~600), EAGLE G6X (JKMxxxN-72HL4-BDX) and EAGLE G7B (JKMxxxN-66HL4M-BDV). It is the newest edition Jinko US lists on its Installation Manuals download page ("202602– UL 61730 Installation Manual (G5, G6, G7)"). It gives series-level installation instructions (mounting zones, test loads, torques, grounding, wiring) and, in Appendix 2, the STC electrical table per power class of each listed series; it does not establish other model ratings. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
US datasheet with one column per module type from JKM420N-54HL4-B to JKM440N-54HL4-B; the mechanical block is set in an outlined font and was cross-read from the rendered page.
Archived copies
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
PDF
ViewOfficial · cdn.myced.com · Official datasheet · PDFSource details
Revision
Not stated
Revision date
Not stated
Linked from the GreenTech Renewables product page with link text "View".
Location: ZZ299200101_DS.pdf
Retrieved Sep 18, 2026
Original PDF preserved byte for byte, found linked from the GreenTech Renewables listing https://www.greentechrenewables.com/product/jinko-solar-430w-108-half-cell-1000v-topcon-blkblk-solar-panel-jkm430n-54hl4-b. The revision is whatever was published at this URL on the access date; exact variant coverage inside the document was not separately verified and no later revision was checked.
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by cdn.myced.com. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
JinkoSolar EAGLE G6R 420-440 W (JKM420-440N-54HL4-B) datasheet
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
JinkoSolar User Manual (UL61730), JinkoSolar Photovoltaic Module (U.S. UL 61730 edition, Edition 2/2026)
Archived copy of a document published by JinkoSolar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
JKM430N-54HL4-B
Manufacturer SKU JKM430N-54HL4-B
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model JKM430N-54HL4-B listed on the California Energy Commission PV Module List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Jinko Solar Co., Ltd, as "JKM430N-54HL4-B", CEC listing date 2022-12-12. This is an equipment listing, not UL certification or complete-system approval.
at Amazon, read Nov 16, 2026Price as of Nov 16, 2026, 5:25 AM PST, may change
at ACOPOWER, read Nov 15, 2026
View product →
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.