Charged ReviewsSaved 0Compare 0Login
CW Energy CWT605-144TNB10
CW Energy
Solar panel

CW Energy CWT605-144TNB10

Key specs

Rated power605 W
Open-circuit voltage52.58 V
Short-circuit current14.48 A
Voltage at max power43.95 V
Current at max power13.77 A
Temperature coefficient-0.3 %/°C

All specifications

Identity

BrandCW Energy · Website
ModelCWT605-144TNB10
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Current at max power13.77 A
Printed as "Maximum Power Current (Imp) 13.62A 13.67A 13.72A 13.77A 13.82A 13.87A 13.92A" in CW Enerji's Installation Manual (V.25.06.01), GROUP 31 CWT144TNB10-TOPCON BIFACIAL table; the 605 Wp column (column 4 of 7) reads "13.77A". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Enerji (cw-enerji.com), which stays listed as an additional source.
Where: PDF page 34, section 9 Applicable Products, GROUP 31 CWT144TNB10-TOPCON BIFACIAL table, "Maximum Power Current (Imp)" row, 605 Wp column
[1] [2]
Short-circuit current14.48 A
Printed as "Short Circuit Current (Isc) 14.30A 14.36A 14.42A 14.48A 14.54A 14.60A 14.66A" in CW Enerji's Installation Manual (V.25.06.01), GROUP 31 CWT144TNB10-TOPCON BIFACIAL table; the 605 Wp column (column 4 of 7) reads "14.48A". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Enerji (cw-enerji.com), which stays listed as an additional source.
Where: PDF page 34, section 9 Applicable Products, GROUP 31 CWT144TNB10-TOPCON BIFACIAL table, "Short Circuit Current (Isc)" row, 605 Wp column
[1] [2]
Voltage at max power43.95 V
Printed as "Maximum Power Voltage (Vmp) 43.35V 43.55V 43.75V 43.95V 44.15V 44.35V 44.55V" in CW Enerji's Installation Manual (V.25.06.01), GROUP 31 CWT144TNB10-TOPCON BIFACIAL table; the 605 Wp column (column 4 of 7) reads "43.95V". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Enerji (cw-enerji.com), which stays listed as an additional source.
Where: PDF page 34, section 9 Applicable Products, GROUP 31 CWT144TNB10-TOPCON BIFACIAL table, "Maximum Power Voltage (Vmp)" row, 605 Wp column
[1] [2]
Open-circuit voltage52.58 V
Printed as "Open Circuit Voltage (Voc) 51.98V 52.18V 52.38V 52.58V 52.78V 52.98V 53.18V" in CW Enerji's Installation Manual (V.25.06.01), GROUP 31 CWT144TNB10-TOPCON BIFACIAL table; the 605 Wp column (column 4 of 7) reads "52.58V". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Enerji (cw-enerji.com), which stays listed as an additional source.
Where: PDF page 34, section 9 Applicable Products, GROUP 31 CWT144TNB10-TOPCON BIFACIAL table, "Open Circuit Voltage (Voc)" row, 605 Wp column
[1] [2]
Bifacialyes
Printed as "BIFACIAL TOPCON MONOCRYSTALLINE 144TNB10" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.
Where: Page 1 heading
[2]
Cell typeTOPCon monocrystalline, n-type
Printed as "BIFACIAL TOPCON MONOCRYSTALLINE 144TNB10" and "16BB n-Type" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.
Where: Page 1 heading
[2]
GroundingThe frame rails have pre-drilled holes marked with a bonding sign. These holes should be used for bonding purposes and must not be used for mounting the Modules.; There is a bonding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the Modules.; The recommended twist torque value is 2.3 N.m.; The recommended torque of locking the nut is 2.0 Nm-2.2 Nm.
Printed as "The frame rails have pre-drilled holes marked with a bonding sign. These holes should be used for bonding purposes and must not be used for mounting the Modules." and, under 7.1 Grounding by Using Grounded Clamp, "There is a bonding hole with 4.2 mm diameter on the edge side closer to the middle of the back frame of the Modules." and "The recommended twist torque value is 2.3 N.m." with "A copper core in size of 12 AWG can be used as bonding clamp."; under 7.2, "The existing Mounting holes which have not been used can be used for bonding." and "The recommended torque of locking the nut is 2.0 Nm-2.2 Nm." in CW Enerji's Installation Manual (V.25.06.01). Third-party bonding devices are allowed "so long as they are certified for bonding Modules".
Where: PDF pages 15 and 16, section 7 Grounding (7.1 grounded clamp, 7.2 unused mounting hole)
[1]
Cell count144 cells
Printed as "144 PCS HALF-CUT CELL" in the group 31 (CWT144TNB10) row of section 9 Applicable Products of CW Enerji's Installation Manual (V.25.06.01). Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Enerji (cw-enerji.com), which stays listed as an additional source.
Where: PDF page 21, section 9 Applicable Products, group 31 row, HÜCRE SAYISI column
[1] [2]
Clamp torque12 to 16 N·m
Printed as "B) Bolt torque requirement: 12-16 Nm" (spelled "Nm") in section 5.2.2 of CW Enerji's Installation Manual (V.25.06.01), for the M8 clamp bolt ("Bolt: M8."). It applies to every product group the manual lists.
Where: PDF page 10, section 5.2.2 Modules Installed with clamp, item B
[1]
DimensionsW 1,134 × L 2,278 × D 35 mm / W 44.65 × L 89.69 × D 1.4 in converted
Printed as "GROUP 31 CWT144TNB10 TOPCON BIFACIAL 590W-620W 144 PCS HALF-CUT CELL 2278*1134*35 390-490 mm" in section 9 Applicable Products of CW Enerji's Installation Manual (V.25.06.01); the PANEL BOYUTU (mm) column reads "2278*1134*35" for group 31 (CWT144TNB10).
Where: PDF page 21, section 9 Applicable Products, group 31 row, PANEL BOYUTU (mm) column
[1]
Rated power605 W
Printed as "Peak Power (Pmax) 590 Wp 595 Wp 600 Wp 605 Wp 610 Wp 615 Wp 620 Wp" in CW Enerji's Installation Manual (V.25.06.01), GROUP 31 CWT144TNB10-TOPCON BIFACIAL table; the 605 Wp column (column 4 of 7) reads "605 Wp". Printed as "All values measured at STC; 1000W/m2, 25°C, 1.5AM" under the tables. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to CW Enerji (cw-enerji.com), which stays listed as an additional source.
Where: PDF page 34, section 9 Applicable Products, GROUP 31 CWT144TNB10-TOPCON BIFACIAL table, "Peak Power (Pmax)" row, 605 Wp column
[1] [2]
Series fuse30 A
Printed as "0-+5W 1500V DC -40 - +85°C Class II Type 29 30A" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026. The values follow the row order Power Tolerance, Maximum System Voltage, Operating Temperature, Protection Class, Fire Class, Maximum Series Fuse Rating.
Where: ELECTRICAL CHARACTERISTICS, "Maximum Series Fuse Rating" row
[2]
Enclosure ratingIP68 (junction box)
Printed as "Junction Box IP68" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.
Where: MECHANICAL SPECIFICATIONS, "Junction Box" row
[2]
Mounting methodsModules can be installed on the frame using mounting holes, clamps, or an insertion system.; Width: Clamp A no less than 38mm, Clamp B no less than 50mm; Bolt: M8; L2-L1: 390-490 mm; Figure 4 layouts: STATIC LOAD +2400Pa/-2400Pa, +5400Pa/-2400Pa, +3600Pa/-2400Pa, +2400Pa/-2400Pa
Printed as "Modules can be installed on the frame using mounting holes, clamps, or an insertion system." (section 5.2) and as "Width: Clamp A no less than 38mm, Clamp B no less than 50mm," with "Bolt: M8." (section 5.2.2) in CW Enerji's Installation Manual (V.25.06.01). The clamp mounting distance for this group is printed as "GROUP 31 CWT144TNB10 TOPCON BIFACIAL 590W-620W 144 PCS HALF-CUT CELL 2278*1134*35 390-490 mm" in section 9, whose last column is headed MONTAJ MESAFESİ ARALIĞI (mm) with L2-L1 below it; the manual says "The L1 and L2 values in Figure 4, represent the mounting distance depending on the model type." The four layouts of Figure 4 and their static load labels were read from rendered page 12 (the labels are not in the text layer): clamps on the long sides at L1/L2, rails across the module at L1/L2, rails along the full long sides, and a fourth layout drawn apart from the others. In the text, the manual prints "the maximum static test load on the back of the Modules is 2400 Pa (i.e., wind load), and the maximum static test load on the front of the Modules is 2400 Pa (i.e., wind and snow load)" and "(Design load: 1600 Pa for wind load, 2400 Pa for snow load, safety factor γm = 1.5)"; because the figure prints different loads by layout, no single front or rear load is recorded.
Where: PDF pages 9 to 12, sections 5.2 Installation Method and 5.3 Description of the installation position (Figures 2 to 4), and PDF page 21, section 9 Applicable Products, group 31 row
[1]
Max system voltage1,500 V
Printed as "0-+5W 1500V DC -40 - +85°C Class II Type 29 30A" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026. The values follow the row order Power Tolerance, Maximum System Voltage, Operating Temperature, Protection Class, Fire Class, Maximum Series Fuse Rating.
Where: ELECTRICAL CHARACTERISTICS, "Maximum System Voltage" row
[2]
Module efficiency23.42 %
Printed in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22) as "CWT605 CWT610 CWT615 CWT620 144TNB10 144TNB10 144TNB10 144TNB10 144TNB10 600Wp 605Wp 610Wp 615Wp 620Wp 23.23 23.42 23.61 23.81 24.00 43.75 43.95 44.15 44.35 44.55 13.72 13.77 13.82 13.87 13.92 52.38 52.58 52.78 52.98 53.18 14.42 14.48 14.54 14.60 14.66", captured on September 25, 2026. The group prints the columns CWT600 (heading glyphs not in the text layer), CWT605, CWT610, CWT615 and CWT620; the second column of each row is CWT605 144TNB10. Standard test conditions: 1000 W/m2, AM 1.5, 25°C.
Where: ELECTRICAL CHARACTERISTICS table, CWT605-144TNB10 column
[2]
Operating temperature-40 to 85 °C / -40 to 185 °F converted
Printed as "0-+5W 1500V DC -40 - +85°C Class II Type 29 30A" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026. The values follow the row order Power Tolerance, Maximum System Voltage, Operating Temperature, Protection Class, Fire Class, Maximum Series Fuse Rating.
Where: ELECTRICAL CHARACTERISTICS, "Operating Temperature" row
[2]
Temperature coefficient-0.3 %/°C
Printed as "Temp. Coeff. of (lse) 0.040%/°C Temp. Coeff. of (Vue) -0.260%/°C Temp. Coeff. of (Pmax) -0.30%/°C" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.
Where: TEMPERATURE CHARACTERISTICS, "Temp. Coeff. of (Pmax)" row
[2]
Isc temperature coefficient0.04 %/°C
Printed as "Temp. Coeff. of (lse) 0.040%/°C Temp. Coeff. of (Vue) -0.260%/°C Temp. Coeff. of (Pmax) -0.30%/°C" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026. The text layer renders the Isc label as "(lse)".
Where: TEMPERATURE CHARACTERISTICS, "Temp. Coeff. of (Isc)" row
[2]
Voc temperature coefficient-0.26 %/°C
Printed as "Temp. Coeff. of (lse) 0.040%/°C Temp. Coeff. of (Vue) -0.260%/°C Temp. Coeff. of (Pmax) -0.30%/°C" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026. The text layer renders the Voc label as "(Vue)".
Where: TEMPERATURE CHARACTERISTICS, "Temp. Coeff. of (Voc)" row
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Rated output
605 WEfficiency 23.42 %W / sq ft 21.8* (Calculated: 605 W ÷ (2,278 mm × 1,134 mm = 27.81 sq ft) = 21.8 W/sq ft)
Voltage (STC)
43.95 VVmp · maximum powerVoc · open circuit 52.58 VMax system 1,500 V
Current (STC)
13.77 AImp · maximum powerIsc · short circuit 14.48 A
Dimensions
D: 35 × W: 1,134 × L: 2,278 mm / D: 1.4 × W: 44.65 × L: 89.69 inWeight Not stated
Warranty
12 yearsPower warranty 30 years

Evidence score

60/10079% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: First-year degradation needed; Weight / watt needed.

Each input is scored against the best documented value for a solar panel, and weight per watt against the best in the panel’s own format. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Certificates and unsupported claims do not add points.

Module efficiency23.42 %23.9 / 26.0

23.42 of 25.5 %, the best documented for a solar panel (printed by the maker): AIKO Comet 3N72 AIKO-A690-MDE72Mw 690W Mono-Glass Module

Printed in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22) as "CWT605 CWT610 CWT615 CWT620 144TNB10 144TNB10 144TNB10 144TNB10 144TNB10 600Wp 605Wp 610Wp 615Wp 620Wp 23.23 23.42 23.61 23.81 24.00 43.75 43.95 44.15 44.35 44.55 13.72 13.77 13.82 13.87 13.92 52.38 52.58 52.78 52.98 53.18 14.42 14.48 14.54 14.60 14.66", captured on September 25, 2026. The group prints the columns CWT600 (heading glyphs not in the text layer), CWT605, CWT610, CWT615 and CWT620; the second column of each row is CWT605 144TNB10. Standard test conditions: 1000 W/m2, AM 1.5, 25°C.

[2]

Product warranty12 years8.4 / 21.0

12 of 30 years, the best documented for a solar panel (printed by the maker): AIKO Neostar 3S+54 AIKO-A480-MCE54Db 480W Dual-Glass Module

Printed as "30 Years Performance Warranty 12 Years Product Warranty" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.

[2]

Power warranty30 years16.0 / 16.0

This is the best documented for a solar panel, printed by the maker. 870 solar panels share this value.

Printed as "30 Years Performance Warranty 12 Years Product Warranty" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.

[2]

Power temperature coefficient-0.3 %/°C11.7 / 16.0

0.3 against 0.22 %/°C, the lowest documented for a solar panel (printed by the maker): Jackery SolarSaga 100 Air

Printed as "Temp. Coeff. of (lse) 0.040%/°C Temp. Coeff. of (Vue) -0.260%/°C Temp. Coeff. of (Pmax) -0.30%/°C" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.

[2]

Weight / wattNot documented0.0 / 5.0

A documented panel weight and rated output are required.

Not documented. Undisclosed data scores 0.

[1] [2]

Not documented, 0 points: First-year degradation.

Each input is compared with the best documented value among published solar panels, weight per watt within the same panel format · Method version 0.4

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Retention87.4 %
at least 87.4% as printed
CW Enerji's certificate of limited warranty prints, for PV modules using TOPCon cell technology, "Within the first 30 (thirty) years, the PV Modules will provide a power output of at least 87.4% of the minimum nominal power specified at the time of sale.", captured on September 25, 2026. The same certificate guarantees at least 94.6% within the first 12 years. It applies to modules sold by CW Enerji and its authorized sales points.
Where: Certificate of Limited Warranty, section B, TOPCon terms
[3] [2]
Warranty term12 years
Printed as "30 Years Performance Warranty 12 Years Product Warranty" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.
Where: Page 1, warranty panel
[2]
Performance warranty30 years
Printed as "30 Years Performance Warranty 12 Years Product Warranty" in the CW Enerji 144TNB10 bifacial datasheet (Ver. 09.22), captured on September 25, 2026.
Where: Page 1, warranty panel
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • CW Enerji Installation Manual (English edition, V.25.06.01)Official · CW Enerji · Official installation manual · PDF
    Source details
    Revision
    V.25.06.01
    Revision date
    Not stated

    Archived copy captured on 2026-10-01.

    Location: Section 9 (Applicable Products), PDF pages 20 to 22, and the group tables on PDF pages 23 to 44

    Retrieved Oct 1, 2026

    The maker's own installation manual for its solar panels, captured 1 October 2026 from cw-enerji.com. Revision V.25.06.01 as printed on every page. Its section 9 (Applicable Products) lists 50 product groups by series code (for example CWT108TN10, CWT108TNB10, CWT132TN12R, CWT144TNFB10) with cell type, power range, cell count, panel size and clamp mounting distance, followed by an electrical table per group (Pmax, Vmp, Imp, Voc and Isc for each power class at STC). The rest of the manual (mounting, clamps, grounding, maintenance) applies to every listed group. It does not name a market edition. Manufacturer instructions and nominal ratings, not independent tests.

    Archived copies

    Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupV.25.06.01 · 2.01 MB

    Archived copy, unaltered, kept as a record of what CW Enerji published. Original address: https://cw-enerji.com/images/down_file/cw-enerji-installation-installation-guide-1167-en.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    44

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: ce4235e66809a3a9eefcb0f22bda48c73387642bebad2351dfaa647cda1621e4

    Open
  • Datasheets

  • CW Enerji 144TNB10 Bifacial TOPCon solar panels datasheet (Ver. 09.22)Official · CW Enerji · Official datasheet · PDF
    Source details
    Revision
    Ver. 09.22
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Page 2, ELECTRICAL CHARACTERISTICS, MECHANICAL SPECIFICATIONS and TEMPERATURE CHARACTERISTICS tables

    Retrieved Sep 24, 2026

    CW Enerji's own 144TNB10 bifacial TOPCon (CWT590-144TNB10 to CWT620-144TNB10) datasheet, served as a PDF from cw-enerji.com (the manufacturer site that also publishes the product pages) and captured on September 25, 2026. It is the manufacturer's published specification (Ver. 09.22); it states that its parameters are for reference only, it does not establish independent test results, and its certification list is a manufacturer claim, not an issuer record.

    Archived copies

    Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupVer. 09.22 · 1.63 MB

    Archived copy, unaltered, kept as a record of what CW Enerji published. Original address: https://cw-enerji.com/images/down_file/144tnb10-620-590wp-topcon-n-type-bifacial-solar-panels-1120-en.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 2923a9c16cae5357e699894a398f084752be712d250503eb25a26641abf5f380

    Open
  • Warranty

  • CW Enerji Certificate of Limited Warranty for CW Enerji brand photovoltaic modulesOfficial · CW Enerji · Official warranty · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Sections A and B

    Retrieved Sep 24, 2026

    CW Enerji's own certificate of limited warranty for CW Enerji brand photovoltaic modules, linked as "CW Enerji Photovoltaic Panel Warranty Certificate" from every CW Enerji panel page and captured on September 25, 2026. It is not model-specific: it sets a 12-year product warranty and a 30-year power output warranty with separate terms for PERC and TOPCon cells, and states that it applies to modules sold by CW Enerji and its authorized sales points. It does not name any U.S. distributor.

    Archived copies

    Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.23 MB

    Archived copy, unaltered, kept as a record of what CW Enerji published. Original address: https://cw-enerji.com/images/down_file/cw-enerji-photovoltaic-panel-warranty-certificate-1563-en.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    3

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: ed81269ab04934c4320ceccfdd4e4baf752a2affa52c00e1aa0d53519f0e1034

    Open
  • Other documents

  • CW Enerji 605Wp 144TNB M10 G2G TopCon Solar PanelOfficial · CW Enerji · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.

    Location: Product gallery (first image); Technical Documents list

    Retrieved Sep 24, 2026

    CW Enerji's own English product page "CW Enerji 605Wp 144TNB M10 G2G TopCon Solar Panel" on cw-enerji.com, captured on September 25, 2026. The page names the product by wattage and series (605Wp) rather than by the full model number; it links the series datasheet that lists CWT605-144TNB10. It is used here only for the product photograph.

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • CW Energy reference documentOfficial · CW Energy · Official document · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Exact printed model on selected source revision only; other region documents not used for numeric facts.

    Location: PDF page 1 literal model/part-number text

    Retrieved Sep 15, 2026

    SHA-256: f80ee43eba6fd78a6ebfbad3d086a69f378bc739ad744a21328331291bf68565

    Archived copies

    Archived copy of a document published by CW Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 14.50 MB

    Archived copy, unaltered, kept as a record of what CW Energy published. Original address: https://cw-enerji.com/images/down_file/144tnb10-620-590wp-topcon-n-type-bifacial-g2g-solar-panels-1536-en.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: f80ee43eba6fd78a6ebfbad3d086a69f378bc739ad744a21328331291bf68565

    Open

Archived documents

CW Energy reference document

Archived copy of a document published by CW Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 14.50 MB

Archived copy, unaltered, kept as a record of what CW Energy published. Original address: https://cw-enerji.com/images/down_file/144tnb10-620-590wp-topcon-n-type-bifacial-g2g-solar-panels-1536-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: f80ee43eba6fd78a6ebfbad3d086a69f378bc739ad744a21328331291bf68565

CW Enerji 144TNB10 Bifacial TOPCon solar panels datasheet (Ver. 09.22)

Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupVer. 09.22 · 1.63 MB

Archived copy, unaltered, kept as a record of what CW Enerji published. Original address: https://cw-enerji.com/images/down_file/144tnb10-620-590wp-topcon-n-type-bifacial-solar-panels-1120-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 2923a9c16cae5357e699894a398f084752be712d250503eb25a26641abf5f380

CW Enerji Certificate of Limited Warranty for CW Enerji brand photovoltaic modules

Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.23 MB

Archived copy, unaltered, kept as a record of what CW Enerji published. Original address: https://cw-enerji.com/images/down_file/cw-enerji-photovoltaic-panel-warranty-certificate-1563-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
3

Embedded dates are file metadata, not independent proof of publication.

SHA-256: ed81269ab04934c4320ceccfdd4e4baf752a2affa52c00e1aa0d53519f0e1034

CW Enerji Installation Manual (English edition, V.25.06.01)

Archived copy of a document published by CW Enerji. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupV.25.06.01 · 2.01 MB

Archived copy, unaltered, kept as a record of what CW Enerji published. Original address: https://cw-enerji.com/images/down_file/cw-enerji-installation-installation-guide-1167-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
44

Embedded dates are file metadata, not independent proof of publication.

SHA-256: ce4235e66809a3a9eefcb0f22bda48c73387642bebad2351dfaa647cda1621e4

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
CWT605-144TNB10

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: panels-0.4-personal
documented pct: 79
basis: Unknown
missing:
First-year degradation needed
Weight / watt needed
criteria:
key: efficiency
label: Module efficiency
value: 23.42
unit: Unknown
shown: 23.42 %
shown detail: Unknown
state: documented
points: 23.9
ceiling: 26
weight: 26
share: 91.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: warranty
label: Product warranty
value: 12
unit: Unknown
shown: 12 years
shown detail: Unknown
state: documented
points: 8.4
ceiling: 21
weight: 21
share: 40
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: performanceWarranty
label: Power warranty
value: 30
unit: Unknown
shown: 30 years
shown detail: Unknown
state: documented
points: 16
ceiling: 16
weight: 16
share: 100
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: powerTemperature
label: Power temperature coefficient
value: 0.3
unit: Unknown
shown: -0.3 %/°C
shown detail: Unknown
state: documented
points: 11.7
ceiling: 16
weight: 16
share: 73.3
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: degradation
label: First-year degradation
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 16
weight: 16
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: weightPerWatt
label: Weight / watt
value: Unknown
unit: Unknown
shown: Not documented
shown detail: Unknown
state: missing
points: 0
ceiling: 5
weight: 5
share: Unknown
covered: no
missing: yes
folded: no
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: A documented panel weight and rated output are required.
display note: Unknown
Sources: [1] [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. CW Enerji Installation Manual (English edition, V.25.06.01) (CW Enerji · manufacturer · V.25.06.01 · observed Oct 1, 2026)
  2. CW Enerji 144TNB10 Bifacial TOPCon solar panels datasheet (Ver. 09.22) (CW Enerji · manufacturer · Ver. 09.22 · observed Sep 24, 2026)
  3. CW Enerji Certificate of Limited Warranty for CW Enerji brand photovoltaic modules (CW Enerji · manufacturer · observed Sep 24, 2026)

Sign in to report an error on this page

Similar products

All with a price