Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Maker series photo: Yaskawa Solectria Solar PVI-50TL-480, the product picture on the first page of the PVI-50TL-480 / PVI-60TL-480 data sheet (document FL.PVI5060TL.01). One picture for both models. Cropped to the inverter. Figure from the manufacturer's document, page 1.Yaskawa Solectria Solar SOLECTRIA PVI-50TL-480
Key specs
All specifications
No spec by that name.
Show all 31 specifications
Identity
SKU detail
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 56 kg / 120 lb converted | Printed as "Inverter: 123.5 lbs (56kg)" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, WEIGHT row, PVI 50TL-480 column. The wire-box is printed separately as 33 lbs (15kg). Table layout read from rendered page 125. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 125, 11.1 Datasheet, WEIGHT row, PVI 50TL-480 column | [2] [1] |
| MPPT count | 3 | Printed as "NUMBER OF MPP TRACKERS 3" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, NUMBER OF MPP TRACKERS row, PVI 50TL-480 column. One cell covers all four models. Table layout read from rendered page 124. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 124, 11.1 Datasheet, NUMBER OF MPP TRACKERS row, PVI 50TL-480 column | [2] [1] |
| AC voltage | 480 | Nominal output voltage; the printed range is -12% to +10%. Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, AC Output | [1] |
| Frequency | 60 Hz | Nominal output frequency; the printed range is 57-63 Hz. Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, AC Output | [1] |
| PV wire size | #14 - #6AWG CU (screw clamp) | Printed as "Wire range: #14 - #6AWG CU" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, DC TERMINATION row, PVI 50TL-480 column. Table layout read from rendered page 125. Where: PDF page 125, 11.1 Datasheet, DC TERMINATION row, PVI 50TL-480 column | [2] |
| Dimensions | W 600 × H 576 × D 260 mm / W 23.6 × H 22.7 × D 10.2 in converted | Power head only, height x width x depth 576 x 600 x 260 mm; the wirebox is printed as 424 x 600 x 260 mm and the overall assembly as 1000 x 600 x 260 mm. One value for both models. Where: Technical data, Mechanical | [1] |
| Communications | RS-485 Modbus RTU; Modbus (proprietary / SunSpec); Ethernet network card required for remote firmware upgrades and diagnostics | Communications rows of the datasheet; SolrenView web-based monitoring and revenue grade metering are printed as optional. One value for both models. Where: Technical data, Communications | [1] |
| Efficiency | 98.8 % | Printed as "MAX. EFFICIENCY 97.0% 98.8% 98.8%" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, MAX. EFFICIENCY row, PVI 50TL-480 column. The last cell covers PVI 50TL-480 and PVI 60TL-480. Table layout read from rendered page 125. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 125, 11.1 Datasheet, MAX. EFFICIENCY row, PVI 50TL-480 column | [2] [1] |
| MPPT voltage | 480 to 850 V | Printed as "MPPT VOLTAGE RANGE 480-850VDC 400-850VDC 480-850VDC 540-850VDC" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, MPPT VOLTAGE RANGE row, PVI 50TL-480 column. Table layout read from rendered page 124. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 124, 11.1 Datasheet, MPPT VOLTAGE RANGE row, PVI 50TL-480 column | [2] [1] |
| Solar input | 90 kW | Maximum PV power, 33 kW per MPPT. Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, DC Input | [1] |
| AC configuration | Three-phase, 480 V AC | The datasheet prints grid connection type "3-Ph/PE/N (neutral conductor optional)" and nominal output voltage 480 VAC. Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, AC Output | [1] |
| Enclosure rating | NEMA Type 4X | Printed as "ENCLOSURE PROTECTION DEGREE NEMA Type 4X" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, ENCLOSURE PROTECTION DEGREE row, PVI 50TL-480 column. Table layout read from rendered page 125. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 125, 11.1 Datasheet, ENCLOSURE PROTECTION DEGREE row, PVI 50TL-480 column | [2] [1] |
| Max PV current | 204 A (68 A per MPPT) | Maximum available PV current, defined on the datasheet as Isc x 1.25. Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, DC Input | [1] |
| Max PV voltage | 1,000 V | Printed as "MAX. DC INPUT VOLTAGE 1000VDC" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, MAX. DC INPUT VOLTAGE row, PVI 50TL-480 column. One cell covers all four models. Table layout read from rendered page 124. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 124, 11.1 Datasheet, MAX. DC INPUT VOLTAGE row, PVI 50TL-480 column | [2] [1] |
| AC output breaker | Suggested 125A | Printed as "MAX AC OCPD RATING 125A 125A Suggested 125A Suggested 125A" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, MAX AC OCPD RATING row, PVI 50TL-480 column. Printed as the maximum AC overcurrent protection device rating. Table layout read from rendered page 124. Where: PDF page 124, 11.1 Datasheet, MAX AC OCPD RATING row, PVI 50TL-480 column | [2] |
| Apparent power | 50,000 VA | Rated apparent power, printed as 50 kVA (factory default); overhead mode is printed as 50 kW / 55 kVA / 66.2 A. Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, AC Output | [1] |
| PV start voltage | 330 V | Printed as "START-UP DC INPUT VOLTAGE / POWER 330V / 80W" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, START-UP DC INPUT VOLTAGE / POWER row, PVI 50TL-480 column. Printed as "330V / 80W" in one cell for all four models. Table layout read from rendered page 124. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 124, 11.1 Datasheet, START-UP DC INPUT VOLTAGE / POWER row, PVI 50TL-480 column | [2] [1] |
| AC output wire size | #6-3/0AWG Cu/Al (M8 stud type terminal block; lugs not supplied) | Printed as "M8 Stud Type Terminal Block (Wire range: #6-3/0AWG Cu/Al)" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, AC TERMINATION row, PVI 50TL-480 column. Table layout read from rendered page 125. Where: PDF page 125, 11.1 Datasheet, AC TERMINATION row, PVI 50TL-480 column | [2] |
| Night consumption | <3 W | Printed as "STAND-BY / NIGHT CONSUMPTION <3W" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, STAND-BY / NIGHT CONSUMPTION row, PVI 50TL-480 column. The row names stand-by and night consumption together; the bound is kept as printed. Table layout read from rendered page 125. Where: PDF page 125, 11.1 Datasheet, STAND-BY / NIGHT CONSUMPTION row, PVI 50TL-480 column | [2] |
| Operating noise | <60 dBA | Printed as "AUDIBLE NOISE EMISSION <60dBA @ 1m and 25°C" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, AUDIBLE NOISE EMISSION row, PVI 50TL-480 column. Measured at 1 m and 25°C as printed; the bound is kept as printed. Table layout read from rendered page 125. Where: PDF page 125, 11.1 Datasheet, AUDIBLE NOISE EMISSION row, PVI 50TL-480 column | [2] |
| Continuous output | 50 kW | Rated AC real power (factory default rating). Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, AC Output | [1] |
| Mounting orientation | 15° to 90° from horizontal; 75° and below: shade cover required | Printed as "to 90° from horizontal. 75° and below: shade cover required" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, MOUNTING / INSTALLATION ANGLE row, PVI 50TL-480 column. Table layout read from rendered page 125. Where: PDF page 125, 11.1 Datasheet, MOUNTING / INSTALLATION ANGLE row, PVI 50TL-480 column | [2] |
| Continuous AC output | 60.2 A | Rated output current at 480 VAC. Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, AC Output | [1] |
| Max PV input current | 108 A 108 A (36 A per MPPT) | Maximum operating input current (clipping point), printed as 108 A (36 A per MPPT). Read from the PVI-50TL-480 column (the first of two model columns; the other is PVI-60TL-480) of the datasheet technical data table; the whole row is quoted. Where: Technical data, DC Input | [1] |
| Operating temperature | -30 to 60 °C / -22 to 140 °F converted | Printed as "- 30°C to +60°C" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, OPERATING TEMPERATURE RANGE row, PVI 50TL-480 column. Derating from +45°C is printed with the range. Table layout read from rendered page 125. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 125, 11.1 Datasheet, OPERATING TEMPERATURE RANGE row, PVI 50TL-480 column | [2] [1] |
| Weighted efficiency | 98.5 % | Printed as "CEC EFFICIENCY 96.5% 97.4% 98.5%" in Solectria's PVI 25TL-208 / PVI-36TL-480-V2 / PVI 50TL-480 / PVI 60TL-480 installation and operation guide (DOCR-071086-C), 11.1 Datasheet, CEC EFFICIENCY row, PVI 50TL-480 column. This is the CEC weighted efficiency; the last cell covers PVI 50TL-480 and PVI 60TL-480. Table layout read from rendered page 125. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to Yaskawa Solectria Solar (solectria.com), which stays listed as an additional source. Where: PDF page 125, 11.1 Datasheet, CEC EFFICIENCY row, PVI 50TL-480 column | [2] [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Continuous output
- 50 kW
- Battery voltage
- Not stated
- Solar input
- 90 kWMPPT trackers 3MPPT range 480 to 850 V
- AC output
- Three-phase, 480 V AC
- Warranty
- 10 years
- Size
- 89.86 L* (Calculated from published dimensions)W: 600 × H: 576 × D: 260 mm / W: 23.6 × H: 22.7 × D: 10.2 inWeight 56 kg / 120 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Standard limited warranty as printed on the datasheet. No warranty document was read, so start date, coverage and exclusions are unknown.
Research pending, 0 points: Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 15 to 50 kW output band. · Method version 0.5
How it worksCertificates
A green check means we found this model, with that standard, on the certifier's own listing, the test lab's own report, or the California Energy Commission's equipment list.
IEEE 1547-2018manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- The Yaskawa Solectria Solar datasheet lists "IEEE 1547-2018" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741-SBmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- The Yaskawa Solectria Solar datasheet lists "UL 1741-SB" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741SA-2016manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- The Yaskawa Solectria Solar datasheet lists "UL 1741SA-2016" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL1699Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- The Yaskawa Solectria Solar datasheet lists "UL1699B" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL1998manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- The Yaskawa Solectria Solar datasheet lists "UL1998" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
CSA-C22.2 No. 107.1-01manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- The Yaskawa Solectria Solar datasheet lists "CSA-C22.2 No. 107.1-01" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
FCC Part 15 (Subpart B, Class A)manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- The Yaskawa Solectria Solar datasheet lists "FCC Part 15 (Subpart B, Class A)" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SAauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- PVI 50TL-480
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Yaskawa Solectria Solar "PVI 50TL-480 {480V}": UL 1741 SA, certifying entity CSA Group, CEC listing date 2017-10-01. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Oct 1, 2017Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
UL 1741 SBauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- PVI 50TL-480
- Limitations
- Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Yaskawa Solectria Solar "PVI 50TL-480 {480V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-03-15, CEC listing date 2017-10-01. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Mar 15, 2022Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
CECauthority listing reportedlisted as of snapshot[3]
- Scope
- equipment listing
- Covered models
- PVI-50TL-480
- Limitations
- Model PVI-50TL-480 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Yaskawa Solectria Solar, as "PVI 50TL-480 {480V}", CEC listing date 2017-10-01. The list prints "PVI 50TL-480"; the record's model "PVI-50TL-480" differs only in punctuation. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: Oct 1, 2017Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [3]
Warranty
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 10 years | Standard limited warranty as printed on the datasheet. No warranty document was read, so start date, coverage and exclusions are unknown. Where: Technical data, Warranty | [1] |
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Yaskawa Solectria Solar Installation and Operation Guide, SOLECTRIA PVI 25TL-208, PVI 36TL-480-V2, PVI 50TL-480 and PVI 60TL-480 (DOCR-071086-C, 04/12/2024)Open
Source details
Archived copy captured on 2026-10-01.
Location: PDF page 1, cover (Listing File Model); PDF pages 124 to 125, 11.1 Datasheet
Retrieved Oct 1, 2026
Yaskawa Solectria Solar's own installation and operation guide for the PVI 25TL-208, PVI-36TL-480-V2, PVI 50TL-480 and PVI 60TL-480 commercial string inverters, reached from the 'PVI 50TL & PVI 60TL Installation and Operation Manual' and 'PVI 25TL-208 Installation and Operation Manual' entries of Solectria's manuals download page and captured 1 October 2026 from solectria.com; document DOCR-071086-C dated 04/12/2024 as printed. The guide writes the models with a space (PVI 25TL-208, PVI 50TL-480, PVI 60TL-480). Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Yaskawa Solectria Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupDOCR-071086-C (04/12/2024) · 6.02 MBArchived copy, unaltered, kept as a record of what Yaskawa Solectria Solar published. Original address: https://www.solectria.com/trainings/support/downloads/installation-operation-manuals/pvi-50-60tl-installation-and-operation-manual/. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 37ce728b7b8f43a3712d59cb3a4169fd2eac27896b68bdda55d0bbfe478cff92
Datasheets
- Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)Open
Certificate & compliance claims (7)
IEEE 1547-2018Manufacturer claim · equipment listingClaimedListed when checked
The Yaskawa Solectria Solar datasheet lists "IEEE 1547-2018" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)UL 1741-SBManufacturer claim · equipment listingClaimedListed when checked
The Yaskawa Solectria Solar datasheet lists "UL 1741-SB" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)UL 1741SA-2016Manufacturer claim · equipment listingClaimedListed when checked
The Yaskawa Solectria Solar datasheet lists "UL 1741SA-2016" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)UL1699BManufacturer claim · equipment listingClaimedListed when checked
The Yaskawa Solectria Solar datasheet lists "UL1699B" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)UL1998Manufacturer claim · equipment listingClaimedListed when checked
The Yaskawa Solectria Solar datasheet lists "UL1998" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)CSA-C22.2 No. 107.1-01Manufacturer claim · equipment listingClaimedListed when checked
The Yaskawa Solectria Solar datasheet lists "CSA-C22.2 No. 107.1-01" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)FCC Part 15 (Subpart B, Class A)Manufacturer claim · equipment listingClaimedListed when checked
The Yaskawa Solectria Solar datasheet lists "FCC Part 15 (Subpart B, Class A)" in its Safety Certifications and Standards row ("IEEE 1547-2018, UL 1741-SB, UL 1741SA-2016, UL1699B, UL1998, CSA-C22.2 No. 107.1-01, FCC Part 15 (Subpart B, Class A)") for PVI-50TL-480. This is recorded as the manufacturer's claim exactly as printed. No certificate number, certification body, file number or issuer directory record was read, so the listing, its scope and its current status are not independently established.
Manufacturer document
Official datasheet: Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Page 2, technical data specifications, per model column
Retrieved Sep 23, 2026
Two-page datasheet for the PVI-50TL-480 and PVI-60TL-480, served as a PDF from solectria.com and archived on September 24, 2026. The technical data table sets the two models side by side, so every figure is read from the named model column and the whole row is quoted. Wirebox versions are named separately. Its standards list is a manufacturer claim that no issuer record was read against.
Archived copies
Archived copy of a document published by Yaskawa Solectria Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupFL.PVI5060TL.01 · 0.36 MBArchived copy, unaltered, kept as a record of what Yaskawa Solectria Solar published. Original address: https://solectria.com/trainings/support/downloads/inverter-datasheets/pvi-50tl-pvi-60tl-transformerless-3-ph-string-inverters-datasheet/. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-06-02
Embedded dates are file metadata, not independent proof of publication.
SHA-256: e341ec2e2d4499496c16ddf0c56afa6a5d7581d61da7d27d6fd99ccec8bda588
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025)
Archived copy of a document published by Yaskawa Solectria Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Yaskawa Solectria Solar published. Original address: https://solectria.com/trainings/support/downloads/inverter-datasheets/pvi-50tl-pvi-60tl-transformerless-3-ph-string-inverters-datasheet/. Copyright and takedown
File details
Original sourcePrinted revision date: 2025-06-02
Embedded dates are file metadata, not independent proof of publication.
SHA-256: e341ec2e2d4499496c16ddf0c56afa6a5d7581d61da7d27d6fd99ccec8bda588
Yaskawa Solectria Solar Installation and Operation Guide, SOLECTRIA PVI 25TL-208, PVI 36TL-480-V2, PVI 50TL-480 and PVI 60TL-480 (DOCR-071086-C, 04/12/2024)
Archived copy of a document published by Yaskawa Solectria Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Yaskawa Solectria Solar published. Original address: https://www.solectria.com/trainings/support/downloads/installation-operation-manuals/pvi-50-60tl-installation-and-operation-manual/. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 37ce728b7b8f43a3712d59cb3a4169fd2eac27896b68bdda55d0bbfe478cff92
Matched on printed specifications
Not documented: Battery voltage range.
Matched on printed specifications only: each maker's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a maker does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- PVI-50TL-480
- Published model / SKU
- PVI 50TL-480
Listing file name printed on the datasheet.
[1]
Manufacturer SKU PVI-50TL-480 · US market
Observed Oct 11, 2026
UL 1741 SA: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Yaskawa Solectria Solar "PVI 50TL-480 {480V}": UL 1741 SA, certifying entity CSA Group, CEC listing date 2017-10-01. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) as Yaskawa Solectria Solar "PVI 50TL-480 {480V}": UL 1741 SB, certifying entity CSA Group, certificate date 2022-03-15, CEC listing date 2017-10-01. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model PVI-50TL-480 listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Yaskawa Solectria Solar, as "PVI 50TL-480 {480V}", CEC listing date 2017-10-01. The list prints "PVI 50TL-480"; the record's model "PVI-50TL-480" differs only in punctuation. This is an equipment listing, not UL certification or complete-system approval.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 75 basis: Unknown missing: Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741-SB · IEEE 1547-2018 +6 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [1] key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Yaskawa Solectria Solar datasheet: SOLECTRIA PVI-50TL-480 / PVI-60TL-480 (Document No. FL.PVI5060TL.01, 06/02/2025) (Yaskawa Solectria Solar · manufacturer · FL.PVI5060TL.01 · observed Sep 23, 2026)
- Yaskawa Solectria Solar Installation and Operation Guide, SOLECTRIA PVI 25TL-208, PVI 36TL-480-V2, PVI 50TL-480 and PVI 60TL-480 (DOCR-071086-C, 04/12/2024) (Yaskawa Solectria Solar · manufacturer · DOCR-071086-C (04/12/2024) · observed Oct 1, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
Sign in to report an error on this page
Similar products
All with a priceSol-Ark 60K-3P-480V
Solis S5-GC60K-LV-US
NEP NEPTUNE NEP-30KW 30 kW three-phase string inverter
Sol-Ark 30K-3P-208V
* Missing details