Y&H NM-ECO-LV-3.6K 3.6 kW 24V hybrid solar inverter (120 V output)

By Y&HSKU NM-ECO-LV-3.6K

Key specs

Units
SKU
NM-ECO-LV-3.6K
Official product page
Sources

Printed as "sku":"NM-ECO-LV-3.6K" in the product data of the Y&H store page. The Amazon listing was only a lead.

Official product page: Y&H store product data for the same page (JSON, October 21, 2026 capture) Checked · Earlier document

Location: Store product data, variants[].sku

Documented

Weight
9 kg20 lb converted
Official user manual
Sources

Printed as "Net Weight, kg" "9" in the 3.6KW column (read from the rendered page).

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 33, Table 6, Net Weight, kg, 3.6KW column

Documented

Peak output
2 x rated power for 5 s
Official user manual
Sources

Printed as "Surge Capacity 2* rated power for 5 seconds", one value for every column; no surge figure in watts is printed, so none is derived.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Surge Capacity

Documented

AC voltage
100/105/110/115/120Vac ±5%
Official user manual
Sources

Printed as "Output Voltage Regulation 100/105/110/115/120Vac±5%" (read from the rendered page), one value for both columns: a selectable 100 to 120 V output. The grid-tie table prints "Nominal Output Voltage 100/105/110/115/120VAC". The Chinese line on the store page says 220VAC; the manual is the primary source and its 120 V edition matches the 3.6 kW SKU the page sells (see the identity notes).

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Output Voltage Regulation

Documented

Battery charging
120 A
Official user manual
Sources

Printed as "Max Charging Current (AC charger plus solar charger)" "120Amp" in the 3.6KW column: the combined AC and solar charging current. No separate solar-only charging current is printed in the manual.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 33, Table 4, MPPT Solar Charging Mode, Max Charging Current (AC charger plus solar charger), 3.6KW column

Documented

Dimensions
15.54 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 334 × H: 423 × D: 110 mmW: 13.1 × H: 16.7 × D: 4.33 in convertedOfficial user manual
Sources

Printed as "Dimension (D*W*H), mm 110X334X423", one value for every column: depth 110 mm, width 334 mm, height 423 mm.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 33, Table 6, Dimension (D*W*H), mm

Calculated

Efficiency
93 %
Official user manual
Sources

Printed as "Peak Efficiency 93%" in inverter (battery) mode, one value for every column. Manufacturer claim, not an independent test.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Peak Efficiency

Documented

MPPT voltage range
60 to 500 V
Official user manual
Sources

Printed as "PV Array MPPT Voltage Range 60Vdc~500Vdc", one value for every column.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 33, Table 4, PV Array MPPT Voltage Range

Documented

PV array limit
4.2 kW
Converted: 4,200 W / 1000 W per kW = 4.2 kW
Official user manual
Sources

Converted: 4,200 W / 1000 W per kW = 4.2 kW

Printed as "Max. PV Array Power 4200W 6500W"; 4200W is the 3.6KW column (read from the rendered page), and the store heading prints the same "Max PV Power 4200W Input". 4,200 W expressed in kW.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 33, Table 4, MPPT Solar Charging Mode, Max. PV Array Power, 3.6KW column

Converted

All specs18
Peak output
2 x rated power for 5 s
Official user manual
Sources

Printed as "Surge Capacity 2* rated power for 5 seconds", one value for every column; no surge figure in watts is printed, so none is derived.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Surge Capacity

Documented

AC voltage
100/105/110/115/120Vac ±5%
Official user manual
Sources

Printed as "Output Voltage Regulation 100/105/110/115/120Vac±5%" (read from the rendered page), one value for both columns: a selectable 100 to 120 V output. The grid-tie table prints "Nominal Output Voltage 100/105/110/115/120VAC". The Chinese line on the store page says 220VAC; the manual is the primary source and its 120 V edition matches the 3.6 kW SKU the page sells (see the identity notes).

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Output Voltage Regulation

Documented

Battery charging
120 A
Official user manual
Sources

Printed as "Max Charging Current (AC charger plus solar charger)" "120Amp" in the 3.6KW column: the combined AC and solar charging current. No separate solar-only charging current is printed in the manual.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 33, Table 4, MPPT Solar Charging Mode, Max Charging Current (AC charger plus solar charger), 3.6KW column

Documented

Efficiency
93 %
Official user manual
Sources

Printed as "Peak Efficiency 93%" in inverter (battery) mode, one value for every column. Manufacturer claim, not an independent test.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Peak Efficiency

Documented

AC frequency
50 Hz / 60 Hz
Official user manual
Sources

Printed as "Output Frequency 50Hz / 60Hz" for the inverter output; the line-mode table prints "Nominal Input Frequency 50Hz / 60Hz (Auto detection)" for the AC input.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Output Frequency

Documented

Grid charge current
80 A
Official user manual
Sources

Printed as "AC Charging Current (Max) 80Amp (@VI/P=100 Vac)", one value for both columns.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 33, Table 4 Charge Mode Specifications, Utility Charging Mode, AC Charging Current (Max), 3.6KW column

Documented

Output waveform
Pure sine wave
Official user manual
Sources

Printed as "Output Voltage Waveform Pure Sine Wave", one value for every column.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Output Voltage Waveform

Documented

Surge duration
5 s
Official user manual
Sources

Printed as "Surge Capacity 2* rated power for 5 seconds".

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Surge Capacity

Documented

Transfer time
10ms typical (UPS); 20ms typical (Appliances)
Official user manual
Sources

Printed as "Transfer Time 10ms typical (UPS); 20ms typical (Appliances)", one value for every column (the OCR reading places the label between the two lines).

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 31, Table 1 Line Mode Specifications, Transfer Time

Documented

Battery voltage
24 V
Official user manual
Sources

Printed as "Nominal DC Input Voltage 24Vdc 48Vdc"; the 24Vdc cell is the 3.6KW column (read from the rendered page).

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, Nominal DC Input Voltage, 3.6KW column

Documented

Idle consumption
45 W
Official user manual
Sources

Printed as "No Load Power Consumption" "45W" in the 3.6KW column (read from the rendered page).

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2, No Load Power Consumption, 3.6KW column

Documented

Continuous output
3.6 kW
Converted: 3,600 W / 1000 W per kW = 3.6 kW
Official user manual
Sources

Converted: 3,600 W / 1000 W per kW = 3.6 kW

Printed as "Rated Output Power" "3.6KW" in the 3.6KW column of a table with one column per power rating (read from the rendered page). Manufacturer claim, not an independent test.

Official user manual: Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF) Checked · Earlier document

Location: PDF page 32, Table 2 Inverter Mode Specifications, Rated Output Power, 3.6KW column

Converted

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF)OfficialY&HOfficial user manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-21.

    Location: PDF pages 31 to 33, section 7 Specifications, Tables 1, 2, 4 and 6, 3.6KW column

    Retrieved

    Y&H's 36-page user manual for its 3.6KW and 6.2KW hybrid inverters in the 100 to 120 V AC edition, filed as NM-ECO-LV-3.6K_327-100179-03G and linked from the NM-ECO-LV-3.6K store page; captured on October 21, 2026. The specification tables give one column per power rating; the 3.6KW column is the NM-ECO-LV-3.6K. The pages are images with no text layer; the specification tables were read from the rendered pages before each label was paired with its column, and the quoted strings are checked against an OCR reading. No date is printed. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Y&H. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Revision not recorded · 18.78 MB

    Archived copy, unaltered, kept as a record of what Y&H published. Original address: https://cdn.shopify.com/s/files/1/0487/1245/0204/files/NM-ECO-LV-3.6K_327-100179-03G.pdf?v=1722334438. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    36
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 92ced77cabdc41d365ae2af24fd0a56591782b92311b858e8680bc1c772eed65

    Open
  • WEB
    Y&H store product page: Y&H 3600W 24V Solar Hybrid Inverter Pure Sine Wave MPPT 120A Solar Controller Two AC Output, Max PV Power 4200W Input (October 21, 2026 capture)OfficialY&HOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-21.

    Location: Product heading; description; manual link

    Retrieved

    Y&H's own store page at yonghuisolar.com (Shenzhen Yonghui Co., Ltd), captured on October 21, 2026; the content is whatever the address served on that date. The page prints a product heading and a short description, and links the user manual. The store prices in euros and names no country or market. Manufacturer claims, not independent tests; the page carries no revision date.

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • WEB
    Y&H store product data for the same page (JSON, October 21, 2026 capture)OfficialY&HOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-21.

    Location: variants[].sku

    Retrieved

    The product data Y&H's store serves for the same product page, captured on October 21, 2026; cited only for the SKU it prints. Manufacturer data, not an independent test.

    Open

Archived documents

Y&H user manual, Hybrid Inverter 3.6KW/6.2KW, Version 1.0, file NM-ECO-LV-3.6K_327-100179-03G (PDF)

Archived copy of a document published by Y&H. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Revision not recorded · 18.78 MB

Archived copy, unaltered, kept as a record of what Y&H published. Original address: https://cdn.shopify.com/s/files/1/0487/1245/0204/files/NM-ECO-LV-3.6K_327-100179-03G.pdf?v=1722334438. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
36
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 92ced77cabdc41d365ae2af24fd0a56591782b92311b858e8680bc1c772eed65

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

Research pending10% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
NM-ECO-LV-3.6K

Manufacturer SKU NM-ECO-LV-3.6K

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.