Charged ReviewsSaved 0Compare 0Login

Victron Energy Inverter 48/1600 VE.Direct NEMA GFCI

Key specs

BrandVictron Energy
ModelInverter 48/1600 VE.Direct NEMA GFCI (UL 458)
MarketUS
Continuous output1.5 kW
Converted: 1500 W x 0.001 = 1.5 kW
Peak output2,100 W
Battery operating voltage36.8 to 62 V
Product warranty5 years

All specifications

Show all 20 specifications

Identity

BrandVictron Energy · Website
ModelInverter 48/1600 VE.Direct NEMA GFCI (UL 458)
MarketUS
Manufacturer SKUPIN482161510
SKU detail
locator: Victron Energy price list 2026-Q3, page 4, row "Inverter 48/1600 VE.Direct NEMA GFCI (UL 458)" PIN482161510
conditions: Victron Energy's 2026-Q3 price list prints article number PIN482161510 on the row for "Inverter 48/1600 VE.Direct NEMA GFCI (UL 458)" (page 4), this record's product.
Sources: [1]
FieldValueConditionsSource
GroundingAC output isolated from DC input and chassis unless the unit is equipped with a GFCI
Printed as "The AC output is isolated from the DC input and the chassis unless the unit is equipped with a Ground Fault Circuit Interrupter (GFCI)." in Victron Energy's Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (PDF page 3). The manual applies to this model: Manual covers Inverter VE.Direct 120V HW15 incl. GFCI models; per-model table rows name 48/1600.
Where: PDF page 3
[2]
Peak output2,100 W
Printed as "Peak power" 2100W/15s for the 1600VA column.
Where: UL 458 Certificate LC20760-1, Ratings table, 1600VA column
[3]
Clearancesclear space of at least 10cm around the appliance for cooling
Printed as "There should be a clear space of at least 10cm around the appliance for cooling." in Victron Energy's Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (PDF page 6). The manual applies to this model: Manual covers Inverter VE.Direct 120V HW15 incl. GFCI models; per-model table rows name 48/1600.
Where: PDF page 6
[2]
DimensionsW 232 × H 117 × D 327 mm / W 9.13 × H 4.61 × D 12.9 in converted
Read from the Victron Energy 2026-Q3 price list, from the row whose article number is PIN482161510. Printed: "117 x 232 x 327". The size column is headed "H x W x D" in millimetres and the weight column "kg". No value was taken from another article number or from a product name.
Where: Pricelist row for article number PIN482161510, column headed "H x W x D" (millimetres), page 4
[4]
CommunicationsVE.Direct
The certified model is named "Inverter 48 | 1600 120V VE.Direct NEMA GFCI".
Where: UL 458 Certificate LC20760-1, Model Nos.
[3]
AC frequency60 Hz
Printed as "60Hz +/-0.1%", shared across every certified model.
Where: UL 458 Certificate LC20760-1, Ratings table
[3]
Max discharge40 A
Printed as the DC input current "40Adc" for the 1600VA class, 48V battery row.
Where: UL 458 Certificate LC20760-1, Ratings table, 1600VA/48V battery cell
[3]
Ground wire sizeat least half the cross-section of the conductors used for the battery connection
Printed as "The earth conductor from the earth lug on the chassis to ground should have at least half the cross-section of the conductors used for the battery connection." in Victron Energy's Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (PDF page 8). The manual applies to this model: Manual covers Inverter VE.Direct 120V HW15 incl. GFCI models; per-model table rows name 48/1600.
Where: PDF page 8
[2]
Surge duration s15 s
Printed as "Peak power" 2100W/15s for the 1600VA column; the duration is 15 seconds.
Where: UL 458 Certificate LC20760-1, Ratings table, 1600VA column
[3]
Battery protectionfuse or DC circuit breaker close to the battery (mandatory for the UL certified NEMA GFCI model)
Printed as "Important note: for the UL certified NEMA GFCI inverter model, it is mandatory to install a fuse or a DC circuit breaker close to the battery, even if the cable length is less than 1.5m." in Victron Energy's Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (PDF page 7). The manual applies to this model: Manual covers Inverter VE.Direct 120V HW15 incl. GFCI models; per-model table rows name 48/1600.
Where: PDF page 7
[2]
Communication portsremote connector; VE.Direct connection
Printed as "Remote on/off control of the inverter can be achieved with a simple on/off switch connected to the inverter remote connector." and "The VE.Direct connection can be used for monitoring of the inverter via a GX device, or to connect to the VictronConnect app." in Victron Energy's Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (PDF page 9). The manual applies to this model: Manual covers Inverter VE.Direct 120V HW15 incl. GFCI models; per-model table rows name 48/1600.
Where: PDF page 9
[2]
Continuous output1.5 kW
Converted: 1500 W x 0.001 = 1.5 kW
Printed as "Cont. Power at 25°C 250W 375W 500W 800W 1200W 1500W" in Certificate Safety UL 458 - Inverter VE.Direct 250VA - 1600VA, UL 458 certificate (LabTest), Ratings table, "Cont. Power at 25°C" row, 12/1600 24/1600 48/1600 column; the model list names "Inverter 48 | 1600 120V VE.Direct NEMA GFCI". Revised on 1 October 2026: The UL 458 certificate prints 1500W at 25°C for the 1600 models and names this GFCI model; 1.5 kW is that figure converted, and no Victron manual, datasheet or product page for the GFCI version is available to us.
Where: UL 458 certificate (LabTest), Ratings table, "Cont. Power at 25°C" row, 12/1600 24/1600 48/1600 column; the model list names "Inverter 48 | 1600 120V VE.Direct NEMA GFCI"
Sources
Converted: 1500 W x 0.001 = 1.5 kW
[3]
Mounting orientationvertically up- or downwards or horizontally up- or downwards
Printed as "Mount the inverter with four screws vertically up- or downwards or horizontally up- or downwards." in Victron Energy's Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (PDF page 6). The manual applies to this model: Manual covers Inverter VE.Direct 120V HW15 incl. GFCI models; per-model table rows name 48/1600.
Where: PDF page 6
[2]
Battery terminal torque2 N·m
Printed as "48/1600 25mm² 4 AWG 2Nm 18 Lb.in" in Victron Energy's Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (PDF page 8). The manual applies to this model: Manual covers Inverter VE.Direct 120V HW15 incl. GFCI models; per-model table rows name 48/1600.
Where: PDF page 8
[2]
Battery voltage range36.8 to 62 V
Printed as "Input DC voltage range" 36.8 – 62V for the 48V battery column.
Where: UL 458 Certificate LC20760-1, Ratings table, 48V battery column
[3]
Operating temperature-40 to +60 °C
Printed as "Operating temperature range -40 to +60°C (fan-assisted cooling)" for this certified GFCI model, and repeated in the Conditions of acceptability. This is the exact model's own certified range; it is not compared against the different (non-GFCI) models' printed range in other Victron documents.
Where: UL 458 Certificate LC20760-1, Ratings table
[3]

Owner reviews

No reviews. Be the first to review this product:
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Evidence score

6/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term5 years6.0 / 30.0

5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.

[5]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
RemedyRepair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretion
Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[5]
ConditionsVoid after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair Centres
Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[5]
Start basisDate of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date
Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.
Where: Victron Energy Limited Warranty Policy, Warranty section
[5]
Warranty term5 years
Brand-wide Victron policy; names no model
Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date." in the Victron Energy Limited Warranty Policy (2025), captured on September 25, 2026. The policy covers Victron Energy products in general and names no model; it lists lead-acid batteries (2 years) and lithium batteries (3 years) as the exceptions. The policy also states that Victron's direct customers can buy 5 more years for a 10% surcharge. The policy is given to Victron's direct customers (OEMs, distributors and dealers), who must pass an identical warranty to the end-user; end-users claim at their place of purchase.
Where: Victron Energy Limited Warranty Policy, "Warranty" section
[5]
Labor and shippingNot included: the warranty does not perform or reimburse de-installation, transportation and re-installation
Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.
Where: Victron Energy Limited Warranty Policy, Warranty section
[5]
Extended warranty5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term ends
Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.
Where: Victron Energy Limited Warranty Policy, Warranty section
[5]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Victron Energy: Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026)Official · Victron Energy · Official instruction manual · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-15.

    Location: Installation instructions

    Retrieved Oct 15, 2026

    Victron Energy's own manual, captured October 15, 2026 with the paced research fetcher (robots.txt read first). Manufacturer instructions, not independent tests.

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 4.29 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Inverter_VE.Direct_120V_-_HW15/106668-Inverter_VE_Direct__Smart_and_SUN-pdf-en.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    28

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 93a8429f0e7ee284bcc0ab4dcd50e15d27ec998e06d0af67d89e870fe9ee824d

    Open
  • Warranty

  • Victron Energy victron warrantyOfficial · Victron Energy · Official warranty · PDF
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Retrieved Sep 10, 2026

    SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

    Archived copies

    Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.11 MB

    Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

    Open
  • Other documents

  • Victron Energy price list 2026-Q3 (EUR C, web edition)Official · Victron Energy B.V. · Official document · PDF
    Source details
    Revision
    2026-Q3
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-23.

    Location: Rows by article number

    Retrieved Sep 22, 2026

    Victron Energy's public 2026-Q3 euro price list, archived on September 23, 2026. It is the one manufacturer document that prints each product name beside its article number in visible text, with an "H x W x D" size column in millimetres and a "kg" column, so every ordering code in this manifest is checked against it. It is read for identity and, where noted, for size; no price is recorded from it. Its size figures for the 1000 A and 2000 A SmartShunts differ from the datasheets, which are recorded instead.

    Archived copies

    Archived copy of a document published by Victron Energy B.V.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup2026-Q3 · 1.84 MB

    Archived copy, unaltered, kept as a record of what Victron Energy B.V. published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    20

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Victron Energy reference document

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup2026 Q3 Euro C · 1.84 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
20

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 8bdf35045bbe43e749f98c4c581834066a2882d1a6b0db045f82ff016974aa50

Victron Energy victron warranty

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.11 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e60b1961ef955fe4844f1e9908c9c55d5072771717fc2ef60b7b92f24e13551e

Certificate Safety UL 458 - Inverter VE.Direct 250VA - 1600VA

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.37 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Certificate-Safety-UL-458-Inverter-VE.Direct-250VA-1600VA.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
None

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 18f3015a7c96bb6a1a710593dba8bd8f50004662ea638b61d1bd0f4db5056b3d

Victron Energy: Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026)

Archived copy of a document published by Victron Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 4.29 MB

Archived copy, unaltered, kept as a record of what Victron Energy published. Original address: https://www.victronenergy.com/upload/documents/Inverter_VE.Direct_120V_-_HW15/106668-Inverter_VE_Direct__Smart_and_SUN-pdf-en.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
28

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 93a8429f0e7ee284bcc0ab4dcd50e15d27ec998e06d0af67d89e870fe9ee824d

Submit a document

Matched on printed specifications

The manufacturer names it

Show all 12

These are the manufacturers’ claims.

Nominal voltage in range

Show all 12
View all 847 batteries in this range

Order: products a manufacturer names first, then by Evidence score at default weights.

Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Inverter 48/1600 VE.Direct NEMA GFCI (UL 458)

Manufacturer SKU PIN482161510 · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 5
unit: Unknown
shown: 5 years
shown detail: Unknown
state: documented
points: 6
ceiling: 30
weight: 30
share: 20
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [5]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Victron Energy price list 2026-Q3 (EUR C, web edition) (Victron Energy B.V. · manufacturer · 2026-Q3 · observed Sep 22, 2026)
  2. Victron Energy: Inverter VE.Direct 120V Manual HW15 GFCI 250, 375, 500, 800, 1200, 1600 (rev 02 - 01/2026) (Victron Energy · manufacturer · observed Oct 15, 2026)
  3. Certificate Safety UL 458 - Inverter VE.Direct 250VA - 1600VA (Victron Energy · manufacturer · observed Sep 18, 2026)
  4. Victron Energy price list EUR C, 2026 Q3 (Victron Energy · manufacturer · 2026-Q3 · observed Sep 19, 2026)
  5. Victron Energy victron warranty (Victron Energy · manufacturer · observed Sep 10, 2026)

Sign in to report an error on this page

Similar products

All with a price

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

* Missing details