About brandTigo Energy makes TS4 module-level power electronics for photovoltaic arrays, including optimizers and rapid shutdown devices, and the EI residential solar-plus-storage system with the EI Inverter and EI Battery.
SKU detail
locator: Page 2, Ordering Information, Part Number
conditions: Tigo prints 601-2111K4-0003 in its Ordering Information table as "11.4kW hybrid inverter, built-in Wi-Fi. Compatible with 200A ATS". The datasheet heading prints the series designation TSI-3.8/7.6/11.4K-US; no per-model TSI string is printed.
Printed as "DC (PV): 12 – 8 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring.
Where: PDF page 23, The EI Inverter, Power Connections, Wiring
Printed as "With a minimum 300 mm (12 in.) clearance around the top and sides." in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), Planning, Component Layout, Inverter.
Where: PDF page 11, Planning, Component Layout, Inverter
Printed once for all models as 80 V - 550 V; full-load voltage range for the 11.4K is 220 V-500 V. Tigo notes the inverter enters standby above 550 V and risks damage over 600 V.
Printed once for all models: nominal voltage 208 V/240 V, grid frequency 50/60 Hz, grid connection type L1/L2/N/PE. Backup output nominal AC voltage is 240 V.
Where: Page 1, Output (AC), Nominal voltage and Grid connection type
Printed as "Enclosure grounding: 10 – 8 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring.
Where: PDF page 23, The EI Inverter, Power Connections, Wiring
60 A 2-pole breaker (when connecting directly to the grid without an ATS)
Printed as "11.4 kW inverter: 60 A 2-pole breaker" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, grid connection steps.
Where: PDF page 24, The EI Inverter, Power Connections, grid connection steps
Printed as "DC (battery): 12 – 8 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring.
Where: PDF page 23, The EI Inverter, Power Connections, Wiring
8 – 6 AWG copper, ferruled, non-fine-stranded (AC to grid or ATS)
Printed as "AC (grid or ATS): 8 – 6 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring.
Where: PDF page 23, The EI Inverter, Power Connections, Wiring
Certifications row as printed by Tigo, one row for all three models. Manufacturer claim; no issuer directory was checked. Listings printed separately: CA-CEC, CA Rule21 CSIP, CA CPUC-SGIP, Hawaii Rule 14H, Rule 22, Rule 27 and Rule 32, Puerto Rico-OGPe.
Read from the 11.4K column (third of three) of the datasheet. Printed as 9880 W at 208 V and 11400 W at 240 V; the 240 V figure is recorded. Maximum apparent power 11400 VA.
Read from the 11.4K column (third of three) of the datasheet. CEC efficiency printed as 98.0% at 240 V and 97.5% at 208 V; the 240 V figure is recorded. Manufacturer claim.
@rmr0 points1 review0 helpful votesJoined Nov 2026
4/5Unverified·
Great overall Support
Warranty
5/5
Software
3/5
Reliability
4/5
Build quality
5/5
Ease of install
4/5
Customer service
4/5
Support has been helpful. My biggest issue is that I would like the app to have an option to connect to the unit so it can give you live data. There have been a few times that the cloud has been slow and my data takes a while to update.
I have the 10kWh battery, and the whole home gateway. Many times the power has gone out and I did not even notice.
Great technical support and working great. Software interface can be buggy but has improved.
Everything worked great out of the box. Install videos and documentation were comprehensive, although some models differ slightly making some decisions confusing (eg how the inverter integrates with the ATS). Everything just works otherwise. I do wish it had an external display so that I could have a better idea of what was happening outside of using the app.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term12.67 years15.2 / 30.0
12.67 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 152 months" and in the feature list as "152 month standard warranty"; converted to years. The warranty terms document was not read.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CSA 22.2-107.1:2016manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
TSI-3.8/7.6/11.4K-US
Limitations
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("CSA 22.2-107.1:2016"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
IEEE 1547.1:2020manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
TSI-3.8/7.6/11.4K-US
Limitations
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547.1:2020"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
IEEE 1547:2018manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
TSI-3.8/7.6/11.4K-US
Limitations
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547:2018"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
UL1699Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
TSI-3.8/7.6/11.4K-US
Limitations
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1699B"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
UL1741 CRD: PCSmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
TSI-3.8/7.6/11.4K-US
Limitations
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741 CRD: PCS"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
UL1741:2021 Ed.3manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
TSI-3.8/7.6/11.4K-US
Limitations
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
UL1741:2021 Ed.3 (PVRSS) (SA) (SB)manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
TSI-3.8/7.6/11.4K-US
Limitations
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3 (PVRSS) (SA) (SB)"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Printed as "Warranty 152 months" and in the feature list as "152 month standard warranty"; converted to years. The warranty terms document was not read.
Location: PDF page 1, title; Appendix A (UL 1741 PCS CRD) inverter list; The EI Inverter chapters
Retrieved Oct 1, 2026
Tigo Energy's own installation manual for the EI Residential Solar Solution (US) with the 200A automatic transfer switch, linked from Tigo's EI Inverter product page and captured 1 October 2026 from Tigo's file host; document 002-00149-00 Rev. 1.6 as printed. It covers the EI Inverter and names the hybrid inverters TSI-3.8K-US, TSI-7.6K-US and TSI-11.4K-US; it does not print Tigo's part numbers. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by Tigo Energy, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL1741:2021 Ed.3Manufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3 (PVRSS) (SA) (SB)"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
CSA 22.2-107.1:2016Manufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("CSA 22.2-107.1:2016"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
UL1741 CRD: PCSManufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741 CRD: PCS"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
UL1699BManufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1699B"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
IEEE 1547:2018Manufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547:2018"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
IEEE 1547.1:2020Manufacturer claim · equipment listingClaimedListed when checked
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547.1:2020"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Page 1 Input, Battery and Output tables; page 2 Ordering Information, Output (Backup), Efficiency and General tables
Retrieved Sep 23, 2026
Recorded document/effective date: Oct 27, 2025
Tigo Energy's own two-page datasheet for the EI Inverter (US), linked from its EI Inverter product page as the English (UL) datasheet and captured on September 24, 2026. The tables print three model columns headed 3.8K, 7.6K and 11.4K; the Ordering Information table maps each Tigo part number to its rating. In the General table the dimensions and weight print two values: the first under the 3.8K column and the second centered across the 7.6K and 11.4K columns. The Certifications and Listings rows are manufacturer claims; no issuer directory was read.
Archived copies
Archived copy of a document published by Tigo Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Description; Downloads, Datasheets
Retrieved Sep 23, 2026
Tigo Energy's own EI Inverter product page, captured on September 24, 2026. Cited for the product description, the link to the datasheet and the product photograph. It carries no revision or date, and its marketing figures are not used.
Archived copy of a document published by Tigo Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Tigo EI Residential Solar Solution US Installation Manual (w/ATS 200A), 002-00149-00 Rev. 1.6
Archived copy of a document published by Tigo Energy, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Matched on printed specifications only: each manufacturer's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a manufacturer does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
601-2111K4-0003
Manufacturer SKU 601-2111K4-0003 · US market
Observed Sep 24, 2026
UL1741:2021 Ed.3: claimed
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3 (PVRSS) (SA) (SB)"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("CSA 22.2-107.1:2016"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741 CRD: PCS"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1699B"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547:2018"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547.1:2020"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.