Tigo EI Inverter 7.6 kW Hybrid Inverter (601-2107K6-0003)

Brand
Tigo Energy
Model
601-2107K6-0003
SKU / part number
601-2107K6-0003 [1]
Category
Inverters

chargedreviews.com/inverters/tigo-energy-601-2107k6-0003

AC output

Continuous output
7.6 kW [1]
Peak output
?
AC configuration
208 V or 240 V, L1/L2/N/PE [1]
AC output voltage
?
AC frequency
?
Grid pass-through
?
Maximum output per leg
?

Battery

Battery voltage
400 V [1]
Battery voltage range
?
Maximum charge current
?
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
15.2 kW [1]
PV input limit (converted)
?
Maximum PV voltage (Voc)
?
MPPT voltage range
80 to 550 V [1]
MPPT trackers
3 [1]
String inputs per MPPT
2 [1]
PV current per MPPT
13.5 A [1]
PV short-circuit current
16.9 A [1]
PV startup voltage
80 V [1]

Efficiency and modes

Peak efficiency
98.4 % [1]
CEC weighted efficiency
97.5 % [1]
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
?
Transfer time
?
Idle consumption
?
Parallel units
?

Communication and environment

Communications
RS-485; Wi-Fi; 4G (optional) [1]
Operating temperature
-25 to 60 °C / -13 to 140 °F converted [1]
Enclosure rating
NEMA 4X/IP65 [1]
Operating noise
?

Mechanical

Dimensions
W 400 × H 638 × D 187 mm / W 15.7 × H 25.1 × D 7.36 in converted [1]
Weight
20.5 kg / 45.2 lb converted [1]

Installation (from the manual)

Conductors

Battery conductors
12 – 8 AWG copper, ferruled, non-fine-stranded [2]
AC input conductors
?
AC output conductors
8 – 6 AWG copper, ferruled, non-fine-stranded (AC to grid or ATS) [2]
PV conductors
12 – 8 AWG copper, ferruled, non-fine-stranded [2]
Ground conductor
10 – 8 AWG copper, ferruled, non-fine-stranded (enclosure grounding) [2]

Protection

AC input breaker
?
AC output breaker
40 A 2-pole breaker (when connecting directly to the grid without an ATS) [2]
Battery fuse or breaker
?
PV disconnect
?

Clearances and orientation

Installation clearances
Minimum 300 mm (12 in.) around the top and sides [2]
Mounting orientation
?

Not in the manual: Torque, Grounding, Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Tigo EI Inverter 7.6 kW Hybrid Inverter (601-2107K6-0003) · 601-2107K6-0003

Warranty

Warranty term12.67 years[1]
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741Claimed present at observation [1]Claimed present at observation [1]
UL 1741 SA?
UL 1741 SB?
IEEE 1547Claimed present at observation [1]Claimed present at observation [1]
CA Rule 21?
UL 9540?
FCC Part 15?
CSA 22.2-107.1:2016Claimed present at observation [1]
UL1699BClaimed present at observation [1]
UL1741 CRD: PCSClaimed present at observation [1]

Documents and sources

  1. Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025) Manufacturer datasheet (PDF) · Revision 002-00081-00 Rev. 4.6 · Revised Oct 27, 2025 · Checked Sep 23, 2026 https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/690b86d4897fb4113443e10e_002-00081-00%204.6%20Datasheet%20EI%20Inverter%2020251027%20-%20EN.pdf
  2. Tigo EI Residential Solar Solution US Installation Manual (w/ATS 200A), 002-00149-00 Rev. 1.6 Installation manual · Revision 002-00149-00 Rev. 1.6 · Revised 2025-10 · Checked Oct 1, 2026 https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/690b88a060aa08c28e99f90c_002-00149-00%201.6%20IO%26M%20EI%20Residential%20US%20200A%2020251027%20-%20EN.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.