12.67 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 152 months" and in the feature list as "152 month standard warranty"; converted to years. The warranty terms document was not read.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Tigo EI Inverter, front view, the image on Tigo's own EI Inverter product page (its file name names the 7600 model)No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 20.5 kg / 45.2 lb converted | Printed once, centered across the 7.6K and 11.4K columns, so it applies to both. Printed as 20.5 kg (45.2 lb.). Where: Page 2, General, Weight | [1] |
| MPPT count | 3 | Read from the 7.6K column (second of three) of the datasheet. Where: Page 1, Input (PV), MPPT, 7.6K column | [1] |
| PV wire size | 12 – 8 AWG copper, ferruled, non-fine-stranded | Printed as "DC (PV): 12 – 8 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring. Where: PDF page 23, The EI Inverter, Power Connections, Wiring | [2] |
| Clearances | Minimum 300 mm (12 in.) around the top and sides | Printed as "With a minimum 300 mm (12 in.) clearance around the top and sides." in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), Planning, Component Layout, Inverter. Where: PDF page 11, Planning, Component Layout, Inverter | [2] |
| Dimensions | W 400 × H 638 × D 187 mm / W 15.7 × H 25.1 × D 7.36 in converted | Printed once, centered across the 7.6K and 11.4K columns, so it applies to both. Printed as 400 x 187 x 638 mm, width by depth by height. Where: Page 2, General, Dimensions (W x D x H) | [1] |
| Communications | RS-485; Wi-Fi; 4G (optional) | Printed as "RS-485 Yes" and "Wi-Fi standard, 4G optional"; the 4G cellular dongle kit is a separate part (301-300000-0001). Where: Page 2, Interfaces | [1] |
| Efficiency | 98.4 % | Read from the 7.6K column (second of three) of the datasheet. Manufacturer claim. Where: Page 2, Efficiency, Max. efficiency, 7.6K column | [1] |
| MPPT voltage | 80 to 550 V | Printed once for all models as 80 V - 550 V; full-load voltage range for the 7.6K is 200 V-500 V. Tigo notes the inverter enters standby above 550 V and risks damage over 600 V. Where: Page 1, Input (PV), MPPT voltage range | [1] |
| Solar array | 15.2 kW | Read from the 7.6K column (second of three) of the datasheet. Printed as 15200 W, the maximum recommended PV array power at STC (2:1 DC/AC ratio). Where: Page 1, Input (PV), Max. Recommended power (STC), 7.6K column | [1] |
| AC configuration | 208 V or 240 V, L1/L2/N/PE | Printed once for all models: nominal voltage 208 V/240 V, grid frequency 50/60 Hz, grid connection type L1/L2/N/PE. Backup output nominal AC voltage is 240 V. Where: Page 1, Output (AC), Nominal voltage and Grid connection type | [1] |
| Enclosure rating | NEMA 4X/IP65 | Printed once for all models. Where: Page 2, General, Enclosure | [1] |
| Ground wire size | 10 – 8 AWG copper, ferruled, non-fine-stranded (enclosure grounding) | Printed as "Enclosure grounding: 10 – 8 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring. Where: PDF page 23, The EI Inverter, Power Connections, Wiring | [2] |
| Max PV current | 13.5 A | Maximum operating input current per MPPT, printed once for all models as 13.5 A/16.9 A (IMP/ISC). Where: Page 1, Input (PV), Max. Input current per MPPT (IMP/ISC) | [1] |
| AC output breaker | 40 A 2-pole breaker (when connecting directly to the grid without an ATS) | Printed as "7.6 kW inverter: 40 A 2-pole breaker" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, grid connection steps. Where: PDF page 24, The EI Inverter, Power Connections, grid connection steps | [2] |
| Apparent power | 7,600 VA | Read from the 7.6K column (second of three) of the datasheet. Where: Page 1, Output (AC), Max. apparent power, 7.6K column | [1] |
| Battery wire size | 12 – 8 AWG copper, ferruled, non-fine-stranded | Printed as "DC (battery): 12 – 8 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring. Where: PDF page 23, The EI Inverter, Power Connections, Wiring | [2] |
| Nominal voltage | 400 V | Nominal battery DC voltage, printed once for all models; a high-voltage battery input. Where: Page 1, Battery (DC), Nominal DC voltage | [1] |
| PV start voltage | 80 V | Printed in the feature list as "80 V starting voltage". Where: Page 1, Features, starting voltage | [1] |
| AC output wire size | 8 – 6 AWG copper, ferruled, non-fine-stranded (AC to grid or ATS) | Printed as "AC (grid or ATS): 8 – 6 AWG" in Tigo's EI Residential Solar Solution US installation manual (w/ATS 200A, 002-00149-00 Rev. 1.6), The EI Inverter, Power Connections, Wiring. Where: PDF page 23, The EI Inverter, Power Connections, Wiring | [2] |
| PV strings per MPPT | 2 | Printed once for all models. Where: Page 1, Input (PV), PV strings per MPPT | [1] |
| Certification claims | UL1741:2021 Ed.3; UL1741:2021 Ed.3 (PVRSS) (SA) (SB); CSA 22.2-107.1:2016; UL1741 CRD: PCS; UL1699B; IEEE 1547:2018; IEEE 1547.1:2020; FCC Part15B; IEEE 2030.5 V2.1 certified gateway; HECO-SRD1547.1:2020 Ed.2 | Certifications row as printed by Tigo, one row for all three models. Manufacturer claim; no issuer directory was checked. Listings printed separately: CA-CEC, CA Rule21 CSIP, CA CPUC-SGIP, Hawaii Rule 14H, Rule 22, Rule 27 and Rule 32, Puerto Rico-OGPe. Where: Page 2, General, Certifications | [1] |
| Continuous output | 7.6 kW | Read from the 7.6K column (second of three) of the datasheet. Printed as 6580 W at 208 V and 7600 W at 240 V; the 240 V figure is recorded. Maximum apparent power 7600 VA. Where: Page 1, Output (AC), Nominal power @208V/240 V, 7.6K column | [1] |
| Max PV short circuit | 16.9 A | Short-circuit current per MPPT, printed once for all models as 13.5 A/16.9 A (IMP/ISC). Where: Page 1, Input (PV), Max. Input current per MPPT (IMP/ISC) | [1] |
| Operating temperature | -25 to 60 °C / -13 to 140 °F converted | Printed once for all models as -25 °C - 60 °C (-13 °F - 140 °F), de-rating above 45 °C/113 °F. Where: Page 2, General, Operating temperature range | [1] |
| Weighted efficiency | 97.5 % | Read from the 7.6K column (second of three) of the datasheet. CEC efficiency printed as 97.5% at 240 V and 97.0% at 208 V; the 240 V figure is recorded. Manufacturer claim. Where: Page 2, Efficiency, CEC efficiency @240 V/@208 V, 7.6K column | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
12.67 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 152 months" and in the feature list as "152 month standard warranty"; converted to years. The warranty terms document was not read.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it works| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 12.67 years | Printed as "Warranty 152 months" and in the feature list as "152 month standard warranty"; converted to years. The warranty terms document was not read. Where: Page 2, Interfaces, Warranty | [1] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-01.
Location: PDF page 1, title; Appendix A (UL 1741 PCS CRD) inverter list; The EI Inverter chapters
Retrieved Oct 1, 2026
Tigo Energy's own installation manual for the EI Residential Solar Solution (US) with the 200A automatic transfer switch, linked from Tigo's EI Inverter product page and captured 1 October 2026 from Tigo's file host; document 002-00149-00 Rev. 1.6 as printed. It covers the EI Inverter and names the hybrid inverters TSI-3.8K-US, TSI-7.6K-US and TSI-11.4K-US; it does not print Tigo's part numbers. Manufacturer instructions, not independent tests.
Archived copy of a document published by Tigo Energy, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Tigo Energy, Inc. published. Original address: https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/690b88a060aa08c28e99f90c_002-00149-00%201.6%20IO%26M%20EI%20Residential%20US%20200A%2020251027%20-%20EN.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 78aae9d172f8eeb799657ad32a444b2d83ae379552b4651eec242e8f377214a3
Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025)Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3 (PVRSS) (SA) (SB)"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025)Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("CSA 22.2-107.1:2016"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025)Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741 CRD: PCS"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025)Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1699B"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025)Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547:2018"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025)Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547.1:2020"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Manufacturer document
Official datasheet: Tigo EI Inverter TSI-3.8/7.6/11.4K-US datasheet, 002-00081-00 Rev. 4.6 (October 27, 2025)Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Page 1 Input, Battery and Output tables; page 2 Ordering Information, Output (Backup), Efficiency and General tables
Retrieved Sep 23, 2026
Recorded document/effective date: Oct 27, 2025
Tigo Energy's own two-page datasheet for the EI Inverter (US), linked from its EI Inverter product page as the English (UL) datasheet and captured on September 24, 2026. The tables print three model columns headed 3.8K, 7.6K and 11.4K; the Ordering Information table maps each Tigo part number to its rating. In the General table the dimensions and weight print two values: the first under the 3.8K column and the second centered across the 7.6K and 11.4K columns. The Certifications and Listings rows are manufacturer claims; no issuer directory was read.
Archived copy of a document published by Tigo Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Tigo Energy published. Original address: https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/690b86d4897fb4113443e10e_002-00081-00%204.6%20Datasheet%20EI%20Inverter%2020251027%20-%20EN.pdf. Copyright and takedown
Printed revision date: 2025-10-27
Embedded dates are file metadata, not independent proof of publication.
SHA-256: b1fb9c9a116ba72ff2167feb4a896ed1dd3b0e576b47430b3e93d32f9f0e9c24
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Description; Downloads, Datasheets
Retrieved Sep 23, 2026
Tigo Energy's own EI Inverter product page, captured on September 24, 2026. Cited for the product description, the link to the datasheet and the product photograph. It carries no revision or date, and its marketing figures are not used.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Tigo Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Tigo Energy published. Original address: https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/690b86d4897fb4113443e10e_002-00081-00%204.6%20Datasheet%20EI%20Inverter%2020251027%20-%20EN.pdf. Copyright and takedown
Printed revision date: 2025-10-27
Embedded dates are file metadata, not independent proof of publication.
SHA-256: b1fb9c9a116ba72ff2167feb4a896ed1dd3b0e576b47430b3e93d32f9f0e9c24
Archived copy of a document published by Tigo Energy, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Tigo Energy, Inc. published. Original address: https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/690b88a060aa08c28e99f90c_002-00149-00%201.6%20IO%26M%20EI%20Residential%20US%20200A%2020251027%20-%20EN.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 78aae9d172f8eeb799657ad32a444b2d83ae379552b4651eec242e8f377214a3
Not documented: Battery voltage range.
Matched on printed specifications only: each maker's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a maker does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.
No sourced accessories or replacement parts listed yet.
Manufacturer SKU 601-2107K6-0003 · US market
Observed Sep 24, 2026
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741:2021 Ed.3 (PVRSS) (SA) (SB)"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("CSA 22.2-107.1:2016"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1741 CRD: PCS"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("UL1699B"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547:2018"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
Observed Sep 24, 2026
Product / system scope unresolved. Manufacturer claim in the Certifications row of Tigo's EI Inverter datasheet 002-00081-00 Rev. 4.6, recorded exactly as printed ("IEEE 1547.1:2020"). The row covers the whole TSI-3.8/7.6/11.4K-US series; no certificate number, issuer or file number is printed beside it, and no issuer directory was checked.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: UL1741:2021 Ed.3 +4 shown detail: Research pending state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 12.67 unit: Unknown shown: 12.67 years shown detail: Unknown state: documented points: 15.2 ceiling: 30 weight: 30 share: 50.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.