- Inverters

AC output
| Continuous output | 3 kW[2] |
|---|---|
| Peak output | 6000VA[2] |
| AC configuration | ? |
| AC output voltage | 120Vac[2] |
| AC frequency | 50Hz ± 0.3Hz 60Hz ± 0.3Hz[2] |
| Grid pass-through | 40 A[2] |
| Maximum output per leg | ? |
Battery
| Battery voltage | 24 V[2] |
|---|---|
| Battery voltage range | 20 to 33 V[2] |
| Maximum charge current | 100 A[2] |
| Maximum discharge current | ? |
| Battery-only output | ? |
| Maximum grid charging | 40 A[2] |
| Compatible batteries / BMS | Lead acid or lithium battery[2] |
PV input
| PV array limit (connected) | ? |
|---|---|
| PV input limit (converted) | ? |
| Maximum PV voltage (Voc) | 108 V[2] |
| MPPT voltage range | 30 to 90 V[2] |
| MPPT trackers | ? |
| String inputs per MPPT | ? |
| PV current per MPPT | 40 A[2] |
| PV short-circuit current | ? |
| PV startup voltage | ? |
Efficiency and modes
| Peak efficiency | 92 %[2] |
|---|---|
| CEC weighted efficiency | ? |
| Battery conversion efficiency | ? |
| Grid / off-grid modes | Off-grid[2] |
| Generator input | Mains or generator connects at the AC input; the dry contact can switch a diesel generator on and off[2] |
| Transfer time | 10 ms[2] |
| Idle consumption | 50 W[5] |
| Parallel units | ? |
Communication and environment
| Communications | USB; RS485; WiFi/GPRS; Dry contact[2] |
|---|---|
| Operating temperature | -10 to 55 °C[2] |
| Enclosure rating | ? |
| Operating noise | ? |
Mechanical
| Dimensions | 378 D × 280 D × 103 D mm[2] |
|---|---|
| Weight | 6.8 kg / 14.99 lb[2] |
Installation (from the manual)
Conductors
| Battery conductors | 30mm2/2AWG[2] |
|---|---|
| AC input conductors | 8mm2/8AWG[2] |
| AC output conductors | 8mm2/8AWG[2] |
| PV conductors | 8mm2/8AWG[2] |
| Ground conductor | not less than 4mm2[2] |
Protection
| AC input breaker | 2P—63A[2] |
|---|---|
| AC output breaker | 2P—63A[2] |
| Battery fuse or breaker | 2P—160A[2] |
| PV disconnect | 2P—63A[2] |
Clearances and orientation
| Installation clearances | Top 200mm, bottom 200mm, left 200mm, right 200mm[2] |
|---|---|
| Mounting orientation | ? |
Grounding
| Grounding and neutral-ground bonding | The ground wire is connected to the grounding screw hole on the cabinet through the O-type terminal.[2] |
|---|
Communication
| Communication ports | USB communication port; RS485/WIFI communication port; Dry contact port[2] |
|---|
Not in the manual: Torque
Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.