AC output
- Continuous output
- 8 kW [1]
- AC configuration
- Three-phase [2]
- AC output voltage
- ?
- AC frequency
- 50/60Hz ± 0.3Hz [1]
- Grid pass-through
- 23.2 A [1]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- ?
- Maximum charge current
- 180 A [1]
- Maximum discharge current
- ?
- Battery-only output
- ?
- Maximum grid charging
- 100 A [1]
- Compatible batteries / BMS
- Li-ion, lead-acid or user-defined batteries [1]
PV input
- PV array limit (connected)
- ?
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- 800 V [2]
- MPPT voltage range
- 200 to 650 V [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- ?
- PV short-circuit current
- 37 A [1]
- PV startup voltage
- ?
Efficiency and modes
- Peak efficiency
- ?
- CEC weighted efficiency
- 97.2 % [2]
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- Generator input; max. generator charging current 100A [1]
- Transfer time
- typical: 10 [1]
- Idle consumption
- ?
- Parallel units
- 6 count [2]
Communication and environment
- Communications
- ?
- Operating temperature
- ?
- Operating noise
- ?
Mechanical
- Dimensions
- 700 × 440 × 260 mm / 27.6 × 17.3 × 10.2 in converted [2]
- Weight
- 39.2 kg / 86.4 lb converted [2]
Installation (from the manual)
Conductors
- Battery conductors
- 53mm²/ 0 AWG [1]
- AC output conductors
- 5mm²/10AWG (L1/L2/L3/N) [1]
- PV conductors
- 5mm²/ 10 AWG [1]
- Ground conductor
- ?
Protection
- Breakers / fuses
- Battery breaker 2P-200A; PV breaker 2P-25A; grid breaker 4P-40A; load breaker 4P-25A [1]
- AC input breaker
- ?
- AC output breaker
- ?
- Battery fuse or breaker
- ?
- PV disconnect
- ?
Not in the manual: Torque, Clearances and orientation, Grounding, Communication