Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GR1P%282%2C5-6%29K_FN_EUR_V1%2C3%2820240227%29.pdf, from a document that names S6-GR1P6K and no other model in this catalog. Printed value: "12kg". Conditions as stated on that sheet. No value was taken from another model or from a name.
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "MPPT number/Max input strings number" with the value "2/2". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "MPPT number/Max input strings number" row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Max. apparent output power (VA)" with the value "6000". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The manual prints no duration for this figure; it is a maximum apparent power, not a surge rating. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Max. apparent output power (VA)" row
W 310 × H 543 × D 160 mm / W 12.2 × H 21.4 × D 6.3 in converted
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Dimensions" with the value "310W*543H*160D (mm)". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Recorded from the W, H and D figures in millimeters. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Dimensions" row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Max.efficiency" with the value "97.7%". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Max.efficiency" row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "MPPT voltage range (Volts)" with the value "90...520". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "MPPT voltage range (Volts)" row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "MPPT number/Max input strings number" with the value "2/2". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "MPPT number/Max input strings number" row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Rated grid voltage (Volts)" with the value "1/N/PE, 220/230". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Rated grid voltage (Volts)" row
Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GR1P%282%2C5-6%29K_FN_EUR_V1%2C3%2820240227%29.pdf, from a document that names S6-GR1P6K and no other model in this catalog. Printed value: "IP66". Conditions as stated on that sheet. No value was taken from another model or from a name.
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Max. input current (Amps)" with the value "14+14". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Max. input current (Amps)" row
Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GR1P%282%2C5-6%29K_FN_EUR_V1%2C3%2820240227%29.pdf, from a document that names S6-GR1P6K and no other model in this catalog. Printed value: "600". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 29, "Max. DC input voltage (Volts)" row
Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GR1P%282%2C5-6%29K_FN_EUR_V1%2C3%2820240227%29.pdf, from a document that names S6-GR1P6K and no other model in this catalog. Printed value: "120". Conditions as stated on that sheet. No value was taken from another model or from a name.
Printed as "Rated output power (Watts) 6000" in Solis user manual, User manual, chapter Specifications (PDF page 29), table headed Model S6-GR1P6K, Rated output power (Watts) row. Revised on 1 October 2026: Solis's user manual prints this rating in watts in this model's specification table, and the kilowatt figure is a direct conversion of that printed value.
Where: User manual, chapter Specifications (PDF page 29), table headed Model S6-GR1P6K, Rated output power (Watts) row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Max short circuit input current (Amps)" with the value "22+22". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Max short circuit input current (Amps)" row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Operating ambient temperature range" with the value "-25℃...+60℃". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Operating ambient temperature range" row
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "EU efficiency" with the value "97.1%". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "EU efficiency" row
26.93 L* (Calculated from published dimensions)W: 310 × H: 543 × D: 160 mm / W: 12.2 × H: 21.4 × D: 6.3 inWeight12 kg / 26 lb
Evidence score
6/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Warranty Terms" with the value "5 Years (Extend to 20 Years)". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC/EN 61000-6-2/-3manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GR1P6K
Limitations
The Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3" in its specifications page for S6-GR1P6K, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
IEC/EN 62109-1/-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GR1P6K
Limitations
The Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3" in its specifications page for S6-GR1P6K, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
The specifications page for S6-GR1P6K in the Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints the row "Warranty Terms" with the value "5 Years (Extend to 20 Years)". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Where: User manual PDF page 29 (left half), specifications for S6-GR1P6K, "Warranty Terms" row
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
1 on file
Manuals
PDF
Solis user manualOfficial · Solis · Official user manual · PDFCertificate & compliance claims (2)
IEC/EN 62109-1/-2Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3" in its specifications page for S6-GR1P6K, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
IEC/EN 61000-6-2/-3Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GR1P(2,5-6)K EUR user manual (file version V1,3(20240227)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3" in its specifications page for S6-GR1P6K, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Solis user manual
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].