Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "3Ф/PE". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Rated grid voltage" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Printed as "Weight 96.3 lbs (43.7 kgs) 105.4 lbs (47.8 kgs) 108.7 lbs (49.3 kgs) 110.5 lbs (50.1 kgs)" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), General Data table; the 60K column reads "110.5 lbs (50.1 kgs)". Recorded from the kilogram figure printed in parentheses. Read on September 25, 2026.
Printed as "MPPT number / Max. input strings number 3 / 6 4 / 8" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), Input DC table; "4 / 8" is printed in one cell spanning the 50K and 60K columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Printed as "Max. apparent output power 25 kVA 33 kVA 36 kVA 40 kVA 50 kVA 60 kVA" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), Output AC table; the 60K column reads "60 kVA". The datasheet prints no duration for this figure; it is a maximum apparent power in kVA, not a surge rating. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "3Ф/PE, 480 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Rated grid voltage" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "60 Hz". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Rated grid frequency" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
If multiple inverters are installed on site, a minimum clearance of 30 inches should be kept between each inverter and all other mounted equipment.; The bottom of the inverter should be at least 30 inches above of the ground or floor.
Printed as "a minimum clearance of 30 inches should be kept between each inverter" and "The bottom of the inverter should be at least 30 inches above of the ground" in the Solis user manual (PDF page 13).
Where: PDF page 13, 3.1.1 Location selection for the inverter
784.86 × 548.64 × 320.04 mm / 30.9 × 21.6 × 12.6 in converted
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "30.9 × 21.6 × 12.6 in (784 × 549 × 320 mm)". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Dimensions (W × H × D)" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Sources
Converted: Published size converted to millimetres
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "Modbus RTU (Sunspec compliant), RS485, Optional: Cellular, Wi-Fi". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Communication" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "98.8%". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Max. efficiency" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "180 - 1000 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "MPPT voltage range" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Printed as "MPPT number / Max. input strings number 3 / 6 4 / 8" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), Input DC table; "4 / 8" is printed in one cell spanning the 50K and 60K columns. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Printed as "Rated grid frequency 60 Hz" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), Output AC table; "60 Hz" is printed in one cell spanning the 25K, 33K, 36K, 40K, 50K and 60K columns. Read on September 25, 2026.
Printed as "Rated grid voltage 3Ф/PE, 480 V" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), Output AC table; "3Ф/PE, 480 V" is printed in one cell spanning the 25K, 33K, 36K, 40K, 50K and 60K columns. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "TYPE 4X". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Ingress protection" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Printed as "Max. input current 40 A / 40 A / 40 A 4 × 40 A" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), Input DC table; "4 × 40 A" is printed in one cell spanning the 50K and 60K columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "1000 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Max. input voltage" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Printed as "480 208 50 65 65 85 85-100 100-125 125" in the Solis user manual (PDF page 30). The table lists seven models in order, S6-GC60K-US sixth, with max. output current 72.2 A, rated voltage 480 Vac and a recommended current range for the OCPD of 100-125 A.
Where: PDF page 30, 3.4.3 Table 3.2 Rating of grid OCPD, S6-GC60K-US entry
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "60 kVA". Conditions as stated in that document. No value was taken from another model or from a product name.
Solis prints no no-load (idle) power for this model in the Solis S6-GC(25-60)K-US flyer V2.1. Its only consumption row is "Self-consumption (night) < 1 W", a night self-consumption figure, now recorded under standby consumption. Revised on 29 September 2026: The recorded 1 W is Solis's printed "Self-consumption (night)" figure, a different quantity from idle consumption (the invert-mode no-load draw; HANDBOOK 5, printed synonyms rule, which names night figures as not read for the idle criterion). The figure is kept, with its source, as standby consumption.
Where: Solis S6-GC(25-60)K-US flyer (V2.1), page 2 datasheet table, General Data, "Self-consumption (night)" row (one value for the 25K, 33K, 36K, 40K, 50K and 60K columns)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "180 V". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Start-up voltage" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "60 kW". Conditions as stated in that document. No value was taken from another model or from a product name.
For vertical installation, this model of Solis inverter should be mounted vertically (90 degrees or backwards in less than or equal to 15 degrees)
Printed as "mounted vertically (90 degrees or backwards in less than or equal to 15 degrees)" in the Solis user manual (PDF page 14). Section 3.1.2.2 adds that for horizontal installation it should be mounted horizontally (upwards in more than 15 degrees off the horizontal plane).
Where: PDF page 14, 3.1.2.3 Vertical wall installation
Printed as "Self-consumption (night) < 1 W" in the Solis S6-GC(25-60)K-US flyer V2.1, captured from the archived copy of the source. Solis labels it night self-consumption and prints it as an upper bound.
Where: Solis S6-GC(25-60)K-US flyer (V2.1), page 2 datasheet table, General Data, "Self-consumption (night)" row (one value for the 25K, 33K, 36K, 40K, 50K and 60K columns)
Printed as "Max. short circuit current 63 A / 63 A / 63 A 4 × 63 A" in the Solis S6-GC(25-60)K-US datasheet (flyer V2.1), Input DC table; "4 × 63 A" is printed in one cell spanning the 50K and 60K columns. The value recorded is the per-tracker current the cell prints. Read on September 25, 2026.
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "-13°F to 140°F (-25°C to 60°C)". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "Operating ambient temperature range" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
Read from Solis's published document at https://www.solisinverters.com/uploads/file/S6-GC(25-60)K-US-Flyer-V2,1.pdf, from a table or row headed by model S6-GC60K-US. Printed: "98.3%". Conditions as stated in that document. No value was taken from another model or from a product name.
Where: flyer PDF page 2 DATASHEET table, "CEC efficiency" row (single value spanning all six model columns 25K/33K/36K/40K/50K/60K)
137.81 L* (Calculated from published dimensions)784.86 × 548.64 × 320.04 mm / 30.9 × 21.6 × 12.6 inWeight50.1 kg / 110 lb
Evidence score
26/100Missing details75% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The specifications page for S6-GC60K-US in the Solis S6-GC(25-60)K-US user manual (file version V1,1(20251013)) prints the row "Warranty" with the value "10 years standard (extend to 20 years)". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Solis prints no no-load (idle) power for this model in the Solis S6-GC(25-60)K-US flyer V2.1. Its only consumption row is "Self-consumption (night) < 1 W", a night self-consumption figure, now recorded under standby consumption. Revised on 29 September 2026: The recorded 1 W is Solis's printed "Self-consumption (night)" figure, a different quantity from idle consumption (the invert-mode no-load draw; HANDBOOK 5, printed synonyms rule, which names night figures as not read for the idle criterion). The figure is kept, with its source, as standby consumption.
Research pending, 0 points: Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same over 50 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CAN/CSA C22.2107.1-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
California Rule 21manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
FCC Part15 ClassBmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Heco Rule 14Hmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
IEEE 1547-2018manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
NEC 690.12-2020manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
UL1699Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
UL1741SBmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
CECauthority listing reportedlisted as of snapshot[5][6]
Scope
equipment listing
Covered models
S6-GC60K-US
Limitations
Model S6-GC60K-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Ginlong Technologies Co., Ltd., as "S6-GC60K-US {480V}", CEC listing date 2023-12-11. Solis's own site (Privacy Policy page on solisinverters.com (US); footer of the same site also reads "Copyright@2019 Ginlong Technologies All Rights Reserved") names Ginlong Technologies Co., Ltd.: "Ginlong Technologies Co.,Ltd. is a limited liability company established in accordance with the laws of the People's Republic of China (hereinafter referred to as "Ginlong" or "we")". This is an equipment listing, not UL certification or complete-system approval.
The specifications page for S6-GC60K-US in the Solis S6-GC(25-60)K-US user manual (file version V1,1(20251013)) prints the row "Warranty" with the value "10 years standard (extend to 20 years)". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Where: User manual PDF page 78 (left half), specifications for S6-GC60K-US, "Warranty" row
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
UL1741SBManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
IEEE 1547-2018Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
UL1699BManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
UL1998Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
FCC Part15 ClassBManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
California Rule 21Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Heco Rule 14HManufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
NEC 690.12-2020Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
CAN/CSA C22.2107.1-1Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(25-60)K-US datasheet (flyer V2.1) prints "Compliance UL1741SB, IEEE 1547-2018, UL1699B, UL1998, FCC Part15 ClassB, California Rule 21, Heco Rule 14H, NEC 690.12-2020, CAN/CSA C22.2107.1-1" in its General Data table, "Compliance" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Solis publishes this datasheet for S6-GC25K-US, among other models named on the same document. Read from https://www.solisinverters.com/us/solarinverter8/25-60k_s6_us.html on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Location: Document title as published
Retrieved Sep 19, 2026
Solis publishes this datasheet for S6-GC25K-US, among other models named on the same document. Read from https://www.solisinverters.com/us/solarinverter8/25-60k_s6_us.html on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Solis publishes this datasheet for S6-GC25K-US, among other models named on the same document. Read from https://www.solisinverters.com/us/solarinverter8/25-60k_s6_us.html on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Location: Document title as published
Retrieved Sep 19, 2026
Solis publishes this datasheet for S6-GC25K-US, among other models named on the same document. Read from https://www.solisinverters.com/us/solarinverter8/25-60k_s6_us.html on 2026-09-19. It establishes only what it prints; no issuer, laboratory or revision-currency check was made.
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
S6-GC60K-US
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model S6-GC60K-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Ginlong Technologies Co., Ltd., as "S6-GC60K-US {480V}", CEC listing date 2023-12-11. Solis's own site (Privacy Policy page on solisinverters.com (US); footer of the same site also reads "Copyright@2019 Ginlong Technologies All Rights Reserved") names Ginlong Technologies Co., Ltd.: "Ginlong Technologies Co.,Ltd. is a limited liability company established in accordance with the laws of the People's Republic of China (hereinafter referred to as "Ginlong" or "we")". This is an equipment listing, not UL certification or complete-system approval.