Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Solis S6-GC(50-75)K-LV series product image from the Solis product pageThree-phase inverter
Solis S6-GC75K-LV
Key specs
Converted: 75000 W x 0.001
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 93 kg / 210 lb converted | Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, from the specification column headed S6-GC75K-LV. Printed value: "93kg". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 38, "Weight" row | [1] |
| MPPT count | 8 | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "MPPT number/Max input strings number" with the value "8/16". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "MPPT number/Max input strings number" row | [1] |
| Peak output | 75,000 VA | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "Max. apparent output power (VA)" with the value "75000". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The manual prints no duration for this figure; it is a maximum apparent power, not a surge rating. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "Max. apparent output power (VA)" row | [1] |
| Dimensions | W 1,014 × H 567 × D 345 mm / W 39.92 × H 22.3 × D 13.6 in converted | Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, from the specification column headed S6-GC75K-LV. Printed value: "1014* 567 * 345 mm". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 38, "Dimensions (W*H*D)" row | [1] |
| Efficiency | 98.5 % | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "Max.efficiency" with the value "98.5%". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "Max.efficiency" row | [1] |
| MPPT voltage | 160 to 1,000 V | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "MPPT voltage range (Volts)" with the value "160...1000". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "MPPT voltage range (Volts)" row | [1] |
| PV input count | 16 | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "MPPT number/Max input strings number" with the value "8/16". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "MPPT number/Max input strings number" row | [1] |
| AC configuration | Three-phase | Phase configuration stated in the manufacturer document. Where: PDF physical pages 1-2; explicit family phase/topology description | [1] |
| Enclosure rating | IP66 | Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, from the specification column headed S6-GC75K-LV. Printed value: "IP66". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 38, "Ingress protection" row | [1] |
| Max PV voltage | 1,100 V | Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, from the specification column headed S6-GC75K-LV. Printed value: "1100". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 38, "Max. DC input voltage (Volts)" row | [1] |
| PV start voltage | 180 V | Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, from the specification column headed S6-GC75K-LV. Printed value: "180". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 38, "Start-up voltage (Volts)" row | [1] |
| Continuous output | 75 kWConverted: 75000 W x 0.001 | Printed as "Rated output power (Watts) 75000" in Solis user manual, User manual, chapter Specifications (PDF page 38), table headed Model S6-GC75K-LV, Rated output power (Watts) row. Revised on 1 October 2026: Solis's user manual prints this rating in watts in this model's specification table, and the kilowatt figure is a direct conversion of that printed value. Where: User manual, chapter Specifications (PDF page 38), table headed Model S6-GC75K-LV, Rated output power (Watts) row SourcesConverted: 75000 W x 0.001 | [1] |
| Operating temperature | -30 to 60 °C / -22 to 140 °F converted | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "Operating ambient temperature range" with the value "-30℃...+60℃". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "Operating ambient temperature range" row | [1] |
| Weighted efficiency | 98 % EU weighted | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "EU efficiency" with the value "98.0%". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "EU efficiency" row | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Continuous output
- 75 kW
- Battery voltage
- Not stated
- Solar input
- Not statedMPPT trackers 8MPPT range 160 to 1000 V
- AC output
- Three-phase
- Warranty
- 5 years
- Size
- 198.35 L* (Calculated from published dimensions)W: 1,014 × H: 567 × D: 345 mm / W: 39.92 × H: 22.3 × D: 13.6 inWeight 93 kg / 210 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "Warranty" with the value "5 years (extand to 20 years)". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026.
Research pending, 0 points: Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same over 50 kW output band. · Method version 0.5
How it worksCertificates
IEC/EN 61000-6-2/-4manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- S6-GC75K-LV
- Limitations
- The Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4" in its specifications page for S6-GC75K-LV, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEC/EN 62109-1/-2manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- S6-GC75K-LV
- Limitations
- The Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4" in its specifications page for S6-GC75K-LV, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEC 61727manufacturer claimunknown[1]
- Scope
- equipment listing
- Covered models
- S6-GC75K-LV
- Limitations
- Solis prints "IEC 61727" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 19, 2026
- Source
- [1]
IEC 62116manufacturer claimunknown[1]
- Scope
- equipment listing
- Covered models
- S6-GC75K-LV
- Limitations
- Solis prints "IEC 62116" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 19, 2026
- Source
- [1]
IEEE 1547manufacturer claimunknown[1]
- Scope
- equipment listing
- Covered models
- S6-GC75K-LV
- Limitations
- Solis prints "IEEE 1547" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedIssuer checked: Sep 19, 2026
- Source
- [1]
Warranty
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 5 years | The specifications page for S6-GC75K-LV in the Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints the row "Warranty" with the value "5 years (extand to 20 years)". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The extension terms are not stated on this page. Read on September 25, 2026. Where: User manual PDF page 38 (right half), specifications for S6-GC75K-LV, "Warranty" row | [1] |
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Solis user manualOpen
Certificate & compliance claims (5)
IEC 62116Manufacturer claim · equipment listingClaimedStatus unconfirmed
Solis prints "IEC 62116" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Manufacturer document
Official user manual: Solis user manualIEC 61727Manufacturer claim · equipment listingClaimedStatus unconfirmed
Solis prints "IEC 61727" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Manufacturer document
Official user manual: Solis user manualIEEE 1547Manufacturer claim · equipment listingClaimedStatus unconfirmed
Solis prints "IEEE 1547" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Manufacturer document
Official user manual: Solis user manualIEC/EN 62109-1/-2Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4" in its specifications page for S6-GC75K-LV, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Manufacturer document
Official user manual: Solis user manualIEC/EN 61000-6-2/-4Manufacturer claim · equipment listingClaimedListed when checked
The Solis S6-GC(50-75)K-LV EUR user manual (file version V1,0(20251125)) prints "IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4" in its specifications page for S6-GC75K-LV, "Safty/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Manufacturer document
Official user manual: Solis user manualSource details
Identity at specified physical page; specifications only where separately field-cited
Location: PDF physical page 4; literal model S6-GC100K in manufacturer model list/table
Retrieved Sep 15, 2026
SHA-256: 4d271cb4e802f2fa05b4c7a530097d643bb79b19d19fe98618ba0b2eb057904e
Archived copies
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 4.94 MBArchived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 4d271cb4e802f2fa05b4c7a530097d643bb79b19d19fe98618ba0b2eb057904e
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Solis user manual
Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 4d271cb4e802f2fa05b4c7a530097d643bb79b19d19fe98618ba0b2eb057904e
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- S6-GC75K-LV
Observed Sep 19, 2026
IEC 62116: claimed
Product / system scope unresolved. Solis prints "IEC 62116" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Observed Sep 19, 2026
IEC 61727: claimed
Product / system scope unresolved. Solis prints "IEC 61727" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Observed Sep 19, 2026
IEEE 1547: claimed
Product / system scope unresolved. Solis prints "IEEE 1547" in a certification, standards or compliance row on PDF page 38 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-GC(50-75)K-LV_EUR_V1,0(20251125).pdf, a document this catalog already attaches to S6-GC75K-LV; the value was located through the specification column headed S6-GC75K-LV. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 75 basis: Unknown missing: Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 22.75 unit: Unknown shown: IEEE 1547 · IEC 62116 +3 shown detail: Claimed state: claimed points: 10.2 ceiling: 45 weight: 45 share: 22.8 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [1] key: warranty label: Warranty term value: 5 unit: Unknown shown: 5 years shown detail: Unknown state: documented points: 6 ceiling: 30 weight: 30 share: 20 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Solis user manual (Solis · manufacturer · observed Sep 15, 2026)
Sign in to report an error on this page
Similar products
All with a priceSol-Ark 60K-3P-480V
Solis S5-GC60K-LV-US
NEP NEPTUNE NEP-30KW 30 kW three-phase string inverter
Sol-Ark 30K-3P-208V
* Missing details