Key specs

Continuous output5 kW
Weight14 kg / 31 lb converted
Efficiency96.6 %

All specifications

Identity

BrandSolis · Website
ModelS6-EO1P5K-48-EU
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight14 kg / 31 lb converted
Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_V1,2(20250721).pdf, from a document that names S6-EO1P5K-48-EU and no other model in this catalog. Printed value: "14kg". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 32, "Net Weight" row
[1]
MPPT count1
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "MPPT number / Max. input strings number" with the value "1/2". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "MPPT number / Max. input strings number" row
[1]
Peak output10kVA
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Surge Capacity" with the value "10kVA". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The manual prints no duration for this figure. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Surge Capacity" row
[1]
Max charge100 A
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Max. charge / discharge current" with the value "100A". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Max. charge / discharge current" row
[1]
DimensionsW 335 × H 450 × D 160 mm / W 13.2 × H 17.7 × D 6.3 in converted
Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_V1,2(20250721).pdf, from a document that names S6-EO1P5K-48-EU and no other model in this catalog. Printed value: "335*450*160mm". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 32, "Dimension(W*H*D)" row
[1]
Efficiency96.6 %
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Peak Efficiency(PV-AC)" with the value "96.6%". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Peak Efficiency(PV-AC)" row
[1]
MPPT voltage90 to 430 V
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "MPPT voltage range" with the value "90-430V". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "MPPT voltage range" row
[1]
PV input count2
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "MPPT number / Max. input strings number" with the value "1/2". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The first figure is the MPPT number and the second the maximum number of input strings. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "MPPT number / Max. input strings number" row
[1]
Solar array6.5 kW
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Recommended max. PV power" with the value "6.5kW". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Recommended max. PV power" row
[1]
Max AC charge80 A
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Max. AC Charge Current" with the value "80A". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 32 (left half), specifications for S6-EO1P5K-48-EU, "Max. AC Charge Current" row
[1]
Max discharge100 A
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Max. charge / discharge current" with the value "100A". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. One figure is printed for charge and discharge. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Max. charge / discharge current" row
[1]
Output waveformPure sine wave
Printed as "Output Voltage Waveform / Pure sine wave" in the maker's document "Solis user manual".
Where: Solis user manual, PDF page 31, Output Voltage Waveform row; spec-table row (the S6-EO1P5K-48-EU specification column; label and value read from the rendered table)
[1]
Enclosure ratingIP21
Read from Solis's published document at https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_V1,2(20250721).pdf, from a document that names S6-EO1P5K-48-EU and no other model in this catalog. Printed value: "IP21". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 32, "Ingress Protection" row
[1]
Max PV voltage500 V
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Max. input voltage" with the value "500V". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Max. input voltage" row
[1]
Max parallel units6 units
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Parallel capability" with the value "6 units". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 32 (left half), specifications for S6-EO1P5K-48-EU, "Parallel capability" row
[1]
PV start voltage90 V
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Start-up voltage" with the value "90V". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Start-up voltage" row
[1]
Continuous output5 kW
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Rated output power" with the value "5kVA/5kW". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. The cell prints an apparent power and a real power; the value recorded is the kW figure. Read on September 25, 2026.
Where: User manual PDF page 31 (right half), specifications for S6-EO1P5K-48-EU, "Rated output power" row
[1]
Operating temperature-10 to 60 °C / 14 to 140 °F converted
The specifications page for S6-EO1P5K-48-EU in the Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints the row "Operation Temperature Range" with the value "-10℃-60℃". The PDF text layer lists the page's row labels and values in separate runs, so the label and the run of values holding this cell are quoted separately. Read on September 25, 2026.
Where: User manual PDF page 32 (left half), specifications for S6-EO1P5K-48-EU, "Operation Temperature Range" row
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
5 kW
Battery voltage
Not stated
Solar input
6.5 kWMPPT trackers 1MPPT range 90 to 430 V
AC output
Not stated
Warranty
Not stated
Size
24.12 L* (Calculated from published dimensions)W: 335 × H: 450 × D: 160 mm / W: 13.2 × H: 17.7 × D: 6.3 inWeight 14 kg / 31 lb

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
55011manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EO1P5K-48-EU
Limitations
The Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints "IEC 62109, IEC 61000, 55011" in its specifications page for S6-EO1P5K-48-EU, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 61000manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
S6-EO1P5K-48-EU
Limitations
The Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints "IEC 62109, IEC 61000, 55011" in its specifications page for S6-EO1P5K-48-EU, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62109manufacturer claimunknown[2]
Scope
equipment listing
Covered models
S6-EO1P5K-48-EU
Limitations
Solis prints "IEC 62109" in a certification, standards or compliance row on PDF page 31 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_FIN_V1,2(20240820).pdf, a document this catalog already attaches to S6-EO1P5K-48-EU; the value was located through the specification column headed S6-EO1P5K-48-EU. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Issuer checked: Sep 19, 2026
Source
[2]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Solis user manualOfficial · Solis · Official user manual · PDF
    Certificate & compliance claims (2)
    IEC 61000Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints "IEC 62109, IEC 61000, 55011" in its specifications page for S6-EO1P5K-48-EU, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    55011Manufacturer claim · equipment listingClaimedListed when checked

    The Solis S6-EO1P(4-5)K-48-EU EUR user manual (file version V1,2(20250721)) prints "IEC 62109, IEC 61000, 55011" in its specifications page for S6-EO1P5K-48-EU, "Safety/EMC standard" row. This records the standard as the manufacturer prints it; no issuer directory or certificate was read against it in this pass. Read on September 25, 2026.

    Manufacturer document

    Official user manual: Solis user manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF physical page 1; literal model S6-EO1P4K-48-EU in manufacturer model list/table

    Retrieved Sep 15, 2026

    SHA-256: d103bc59416bbe6f0f85f4834f12da7aa7617d1691d5471d78b1e35cb0cde209

    Archived copies

    Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 3.12 MB

    Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_V1,2(20250721).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    32

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d103bc59416bbe6f0f85f4834f12da7aa7617d1691d5471d78b1e35cb0cde209

    Open

Archive and older revisions

Archive and older revisions1

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

  • Solis user manualOfficial · Solis · Official user manual · PDF
    Certificate & compliance claims (1)
    IEC 62109Manufacturer claim · equipment listingClaimedStatus unconfirmed

    Solis prints "IEC 62109" in a certification, standards or compliance row on PDF page 31 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_FIN_V1,2(20240820).pdf, a document this catalog already attaches to S6-EO1P5K-48-EU; the value was located through the specification column headed S6-EO1P5K-48-EU. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

    Manufacturer document

    Official user manual: Solis user manual
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF physical page 1; literal model S6-EO1P4K-48-EU in manufacturer model list/table

    Retrieved Sep 15, 2026

    SHA-256: 2e6524b27e70ceb1a7880940bb40d0a89ae9dabc98dc2fa4d9fcd57ae45d1fde

    Archived copies

    Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 3.06 MB

    Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_FIN_V1,2(20240820).pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    32

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 2e6524b27e70ceb1a7880940bb40d0a89ae9dabc98dc2fa4d9fcd57ae45d1fde

    Open

Archived documents

Solis user manual

Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 3.06 MB

Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_FIN_V1,2(20240820).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
32

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 2e6524b27e70ceb1a7880940bb40d0a89ae9dabc98dc2fa4d9fcd57ae45d1fde

Solis user manual

Archived copy of a document published by Solis. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 3.12 MB

Archived copy, unaltered, kept as a record of what Solis published. Original address: https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_V1,2(20250721).pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
32

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d103bc59416bbe6f0f85f4834f12da7aa7617d1691d5471d78b1e35cb0cde209

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
S6-EO1P5K-48-EU
  1. Observed Sep 19, 2026

    IEC 62109: claimed

    Product / system scope unresolved. Solis prints "IEC 62109" in a certification, standards or compliance row on PDF page 31 of https://www.solisinverters.com/uploads/file/Solis_Manual_S6-EO1P(4-5)K-48-EU_EUR_FIN_V1,2(20240820).pdf, a document this catalog already attaches to S6-EO1P5K-48-EU; the value was located through the specification column headed S6-EO1P5K-48-EU. This is a manufacturer statement only: no issuer listing, certificate number, edition, scope or validity was checked, and the printed row may cover further models in the same family.

    [2]

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 0
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: IEC 62109 · IEC 61000 +1
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Solis user manual (Solis · manufacturer · observed Sep 15, 2026)
  2. Solis user manual (Solis · manufacturer · observed Sep 15, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details