Sol-Ark
Hybrid inverter

Sol-Ark 8K-2P-N

Key specs

Weight35.4 kg / 78 lb converted
Continuous output8 kW
Converted: 8,000 W / 1000 = 8 kW
Max PV voltage500 V
Efficiency97.5 %
Max charge185 A
MPPT count2
Sol-Ark 8K-2P-Nread Nov 15, 2026

All specifications

Identity

BrandSol-Ark · Website
Model8K-2P-N
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: Ordering SKU not established.
Sources: No source on record
FieldValueConditionsSource
Weight35.4 kg / 78 lb converted
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "35.4 kg / 78 lb.". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "Weight" row
[1]
MPPT count2
Printed as "No. of MPP Trackers 2" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026.
Where: Datasheet, Input Data (PV), "No. of MPP Trackers" row
[1]
Peak output16,000 VA for 10 s; 25,000 VA for 100 ms (off-grid, at 240 V)
Printed as "Peak Apparent Power (10s, off-grid)" 16,000VA @ 240V and "Peak Apparent Power (100ms, off-grid)" 25,000VA @ 240V in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. Stated in VA, not W.
Where: Datasheet, Output Data (AC), "Peak Apparent Power" rows
[1]
AC voltage120/240V, 120/208V, 220V
Printed as "Nominal AC Voltage 120/240V, 120/208V, 220V" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Output Data (AC)
[2]
Max charge185 A
Printed as "Max. Battery Charge / Discharge Current 185A" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Battery Input Data (DC)
[2]
PV wire size12 to 10 AWG (MPPT, 25 A DC)
Printed as "MPPT 25A DC 12 - 10 AWG" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), section 1.3, Connection Requirements, captured on September 26, 2026.
Where: Section 1.3, Connection Requirements
[2]
DimensionsW 750 × H 450 × D 254 mm / W 29.5 × H 17.7 × D 10 in converted
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "750 x 450 x 254 mm / 29.5 x 17.7 x 10 in". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "Dimensions (H x W x D)" row
[1]
CommunicationsCANBus; RS485 MODBUS; Wi-Fi; LAN
Printed as "BMS Communication CANBus & RS485 MODBUS" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026. The same page prints "Communication and Monitoring Wi-Fi & LAN Hardware Included".
Where: Embedded datasheet
[2]
Efficiency97.5 %
Printed as "Max Efficiency 97.5%" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026; the same section prints "CEC Efficiency 96.5%". Manufacturer rating; no test conditions are given.
Where: Datasheet, Output Data (AC), "Max Efficiency" row
[1]
MPPT voltage150 to 500 V
Printed as "MPPT Voltage Range 150 - 500V" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026. Rated MPPT operating range 175 - 425V.
Where: Embedded datasheet, Input Data (PV)
[2]
Solar array11 kW
Converted: 11,000 W / 1000 = 11 kW
Printed as "Max. Allowed PV Power (STC) 11,000W" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. The largest PV array Sol-Ark allows at STC.
Where: Datasheet, Input Data (PV), "Max. Allowed PV Power (STC)" row
Sources
Converted: 11,000 W / 1000 = 11 kW
[1]
AC frequency50 / 60 Hz
Printed as "Grid Frequency 50 / 60Hz" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Output Data (AC)
[2]
Max discharge185 A
Printed as "Max. Battery Charge / Discharge Current 185A" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Battery Input Data (DC)
[2]
AC configuration120/240 V, 120/208 V, 220 V
Printed as "Nominal AC Voltage 120/240V, 120/208V, 220V" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026.
Where: Datasheet, Output Data (AC), "Nominal AC Voltage" row
[1]
Enclosure ratingIP65
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "IP65 / NEMA 3R". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "Enclosure" row
[1]
Max PV current18 A
Printed as "Max. Operating Input Current per MPPT 18A (self-limiting)" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Input Data (PV)
[2]
Max PV voltage500 V
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "500V". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "Max. Input Voltage" row
[1]
Transfer time4 ms
Printed as "Backup Transfer Time 4ms" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Output Data (AC)
[2]
Battery wire size2/0 to 4/0 AWG (battery port, 185 A DC)
Printed as "Battery Port 185A DC 2/0 - 4/0 AWG" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), section 1.3, Connection Requirements, captured on September 26, 2026.
Where: Section 1.3, Connection Requirements
[2]
Generator supportAutomatic Generator Start (AGS), 2 Wire Start, integrated
Printed as "Automatic Generator Start (AGS) 2 Wire Start - Integrated" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Battery Input Data (DC)
[2]
Nominal voltage48 V
Printed as "Nominal DC Voltage 48V" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026; the operating range is printed as 43 - 63V.
Where: Datasheet, Battery Input Data (DC), "Nominal DC Voltage" row
[1]
PV efficiency97.5 %
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "97.5%". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "Max Efficiency" row
[1]
AC input wire size6 to 4 AWG (GRID, 63 A AC)
Printed as "GRID 63A AC 6 - 4 AWG" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), section 1.3, Connection Requirements, captured on September 26, 2026. Runs should be sized for at or below 2.5% voltage drop at full load.
Where: Section 1.3, Connection Requirements
[2]
Grid passthrough63 A
Printed as "Max. Grid Passthrough Current 63A" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Output Data (AC)
[2]
Idle consumption60 W
Printed as "Idle consumption - No Load 60W" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, General Data
[2]
PV start voltage125 V
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "125V". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "Startup Voltage" row
[1]
Terminal torque10 N·m
Printed as "Battery Connection 90 in-lb 10 Nm" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), torque table, captured on September 26, 2026.
Where: Section 1, Torque table
[2]
AC output wire size6 to 4 AWG (LOAD, 63 A AC)
Printed as "LOAD 63A AC 6 - 4 AWG" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), section 1.3, Connection Requirements, captured on September 26, 2026.
Where: Section 1.3, Connection Requirements
[2]
Operating noise30 dBA
< 30 dB as printed
Printed as "Noise < 30 dB @ 25°C (77°F)" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026. Printed as an upper bound in dB.
Where: Embedded datasheet, General Data
[2]
PV strings per MPPT2
Printed as "No. of PV Strings per MPPT 2" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Input Data (PV)
[2]
Continuous output8 kW
Converted: 8,000 W / 1000 = 8 kW
Printed as "Real Power, max continuous 8,000W" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026.
Where: Datasheet, Output Data (AC), "Real Power, max continuous" row
Sources
Converted: 8,000 W / 1000 = 8 kW
[1]
Battery compatibilityLithium / Lead Acid
Printed as "Battery Technologies Lithium / Lead Acid" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026. Battery chemistries only; no battery models are listed there.
Where: Embedded datasheet, Battery Input Data (DC)
[2]
Battery voltage range43 to 63 V
Printed as "Operating Voltage Range 43 - 63V" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.
Where: Embedded datasheet, Battery Input Data (DC)
[2]
Operating temperature-25 to 55 °C / -13 to 131 °F converted
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "-25~55°C, > 45°C Derating". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "Ambient Temperature" row
[1]
Other compliance claimsCA Rule 21, HECO Rule 14H
Listed in the Protection and Certifications section of the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026, after the numbered standards recorded as certification claims. Utility interconnection rules Sol-Ark lists; no certificate or issuer record is given.
Where: Datasheet, Protection and Certifications
[1]
Weighted efficiency96.5 %
Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf, from a document that names 8K-2P-N and no other model in this catalog. Printed value: "96.5%". Conditions as stated on that sheet. No value was taken from another model or from a name.
Where: PDF page 1, "CEC Efficiency" row
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

Lowest first. Each price is the date we last read it; it may have changed. Stock isn't shown.

StorePriceReadDetailsSource
SanTan Solar$4,999Nov 15, 2026One unit as listed by SanTan Solar on October 15, 2026; tax and shipping excluded. Not refreshed automatically yet. · Store SKU Sol-Ark-8K
Price readings (19)
  • Oct 15, 2026: $4,999
  • Oct 17, 2026: $4,999
  • Oct 20, 2026: $4,999
  • Oct 25, 2026: $4,999
  • Oct 26, 2026: $4,999
  • Oct 28, 2026: $4,999
  • Oct 29, 2026: $4,999
  • Oct 30, 2026: $4,999
  • Oct 31, 2026: $4,999
  • Nov 1, 2026: $4,999
  • Nov 2, 2026: $4,999
  • Nov 3, 2026: $4,999
  • Nov 4, 2026: $4,999
  • Nov 6, 2026: $4,999
  • Nov 9, 2026: $4,999
  • Nov 12, 2026: $4,999
  • Nov 13, 2026: $4,999
  • Nov 14, 2026: $4,999
  • Nov 15, 2026: $4,999
[3]View now Paid link

Price history

Prices we read at SanTan Solar · 20 readings · no change in our readings since

Chart, listings & data

Since · Listing price (USD)

View listing at SanTan Solar Paid link
$4,500$4,750$5,000$5,250SanTan Solar: $4,999 · Oct 15, 2026, 3:16 PM PDTSanTan Solar: $4,999 · Oct 17, 2026, 3:31 AM PDTSanTan Solar: $4,999 · Oct 20, 2026, 4:32 AM PDTSanTan Solar: $4,999 · Oct 25, 2026, 3:01 AM PDTSanTan Solar: $4,999 · Oct 26, 2026, 1:06 AM PDTSanTan Solar: $4,999 · Oct 28, 2026, 2:11 AM PDTSanTan Solar: $4,999 · Oct 29, 2026, 2:40 AM PDTSanTan Solar: $4,999 · Oct 30, 2026, 2:40 AM PDTSanTan Solar: $4,999 · Oct 31, 2026, 2:31 AM PDTSanTan Solar: $4,999 · Nov 1, 2026, 2:31 AM PSTSanTan Solar: $4,999 · Nov 2, 2026, 2:50 AM PSTSanTan Solar: $4,999 · Nov 3, 2026, 3:01 AM PSTSanTan Solar: $4,999 · Nov 4, 2026, 4:21 AM PSTSanTan Solar: $4,999 · Nov 6, 2026, 1:06 AM PSTSanTan Solar: $4,999 · Nov 9, 2026, 3:11 AM PSTSanTan Solar: $4,999 · Nov 12, 2026, 1:25 AM PSTSanTan Solar: $4,999 · Nov 13, 2026, 1:06 AM PSTSanTan Solar: $4,999 · Nov 14, 2026, 12:25 AM PSTSanTan Solar: $4,999 · Nov 15, 2026, 12:15 AM PSTOct 15, 2026Nov 15, 2026
SanTan Solar$4,999Nov 15, 2026, 12:15 AM PSTLatest check · hover or tap for earlier prices

A break in a line is a gap in our readings: no price is drawn for days we did not read.

Price data
Collected price observations by seller
CheckedSellerPrice
Oct 15, 2026, 3:16 PM PDTSanTan Solar Paid link$4,999
Oct 17, 2026, 3:31 AM PDTSanTan Solar Paid link$4,999
Oct 20, 2026, 4:32 AM PDTSanTan Solar Paid link$4,999
Oct 25, 2026, 3:01 AM PDTSanTan Solar Paid link$4,999
Oct 26, 2026, 1:06 AM PDTSanTan Solar Paid link$4,999
Oct 28, 2026, 2:11 AM PDTSanTan Solar Paid link$4,999
Oct 29, 2026, 2:40 AM PDTSanTan Solar Paid link$4,999
Oct 30, 2026, 2:40 AM PDTSanTan Solar Paid link$4,999
Oct 31, 2026, 2:31 AM PDTSanTan Solar Paid link$4,999
Nov 1, 2026, 2:31 AM PSTSanTan Solar Paid link$4,999
Nov 2, 2026, 2:50 AM PSTSanTan Solar Paid link$4,999
Nov 3, 2026, 3:01 AM PSTSanTan Solar Paid link$4,999
Nov 4, 2026, 4:21 AM PSTSanTan Solar Paid link$4,999
Nov 6, 2026, 1:06 AM PSTSanTan Solar Paid link$4,999
Nov 6, 2026, 2:01 AM PSTSanTan Solar Paid link$4,999
Nov 9, 2026, 3:11 AM PSTSanTan Solar Paid link$4,999
Nov 12, 2026, 1:25 AM PSTSanTan Solar Paid link$4,999
Nov 13, 2026, 1:06 AM PSTSanTan Solar Paid link$4,999
Nov 14, 2026, 12:25 AM PSTSanTan Solar Paid link$4,999
Nov 15, 2026, 12:15 AM PSTSanTan Solar Paid link$4,999

Quick reference sheet

Continuous output
8 kW
Battery voltage
43 to 63 V
Solar input
11 kWMPPT trackers 2MPPT range 150 to 500 V
AC output
120/240 V, 120/208 V, 220 V
Warranty
10 years
Size
85.72 L* (Calculated from published dimensions)W: 750 × H: 450 × D: 254 mm / W: 29.5 × H: 17.7 × D: 10 inWeight 35.4 kg / 78 lb

Evidence score

26/100Missing details85% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 SB · UL 1741-2010/2018 +2Claimed14.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[1]

Warranty term10 years12.0 / 30.0

10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Standard Warranty 10 Years" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. No separate warranty document for this model was read.

[1]

Idle consumption60 W0.2 / 10.0

60 against 1 W, the lowest documented for an inverter in the 7 to 15 kW output band (printed by the maker): Fronius Primo 11.4-1 208-240. The bar is a printed bound: less than 1 W, as printed.

Printed as "Idle consumption - No Load 60W" in the Sol-Ark 8K-2P-N installation manual (SK140-0005-002), embedded datasheet, captured on September 26, 2026.

[2]

Research pending, 0 points: Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
FCC 15 Class Bmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
8K-2P-N
Limitations
Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "FCC 15 Class B".
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEEE 1547a 2003/2014manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
8K-2P-N
Limitations
Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "IEEE1547a 2003/2014".
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741-2010/2018manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
8K-2P-N
Limitations
Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741-2010/2018".
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741 SBmanufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
8K-2P-N
Limitations
Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741SB".
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

FieldValueConditionsSource
Warranty term10 years
Printed as "Standard Warranty 10 Years" in the Sol-Ark 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. No separate warranty document for this model was read.
Where: Datasheet, General Data, "Standard Warranty" row
[1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Sol-Ark 8K-2P-N installation manual (SK140-0005-002)Official · Sol-Ark · Official installation manual · PDF
    Source details
    Revision
    SK140-0005-002
    Revision date
    Not stated

    Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.

    Location: Section 1, embedded datasheet and Connection Requirements

    Retrieved Sep 25, 2026

    Sol-Ark's own installation manual for the 8K-2P-N, listed in its Product Document Library and captured on September 26, 2026. Includes an embedded datasheet page; manufacturer claims, not a certificate.

    Archived copies

    Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupSK140-0005-002 · 4.76 MB

    Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/06/SK140-0005-002-8K-2P-N-EN-Manual-1-1.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    54

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 2d78833f0dfd3579b769cf106c70364e0625a0c829d5b3a286abdb1291f9cdc1

    Open
  • Datasheets

  • Sol-Ark datasheetOfficial · Sol-Ark · Official datasheet · PDF
    Certificate & compliance claims (4)
    UL 1741-2010/2018Manufacturer claim · equipment listingClaimedListed when checked

    Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741-2010/2018".

    Manufacturer document

    Official datasheet: Sol-Ark datasheet
    IEEE 1547a 2003/2014Manufacturer claim · equipment listingClaimedListed when checked

    Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "IEEE1547a 2003/2014".

    Manufacturer document

    Official datasheet: Sol-Ark datasheet
    FCC 15 Class BManufacturer claim · equipment listingClaimedListed when checked

    Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "FCC 15 Class B".

    Manufacturer document

    Official datasheet: Sol-Ark datasheet
    UL 1741 SBManufacturer claim · equipment listingClaimedListed when checked

    Listed on the certifications line of Sol-Ark's own 8K-2P-N datasheet Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741SB".

    Manufacturer document

    Official datasheet: Sol-Ark datasheet
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Identity at specified physical page; specifications only where separately field-cited

    Location: PDF page 1

    Retrieved Sep 15, 2026

    SHA-256: 68a7e7c47d668563937233dce585bb87f9ce30d07a056cd2e1d148bf4b23ec40

    Archived copies

    Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 0.09 MB

    Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    1

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 68a7e7c47d668563937233dce585bb87f9ce30d07a056cd2e1d148bf4b23ec40

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Sol-Ark datasheet

Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.09 MB

Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/06/8K-2P-N_DATASheet_EN_Rev2_19June2025.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
1

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 68a7e7c47d668563937233dce585bb87f9ce30d07a056cd2e1d148bf4b23ec40

Sol-Ark 8K-2P-N installation manual (SK140-0005-002)

Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupSK140-0005-002 · 4.76 MB

Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/06/SK140-0005-002-8K-2P-N-EN-Manual-1-1.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
54

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 2d78833f0dfd3579b769cf106c70364e0625a0c829d5b3a286abdb1291f9cdc1

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
8K-2P-N

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 85
basis: Unknown
missing:
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 31.5
unit: Unknown
shown: UL 1741 SB · UL 1741-2010/2018 +2
shown detail: Claimed
state: claimed
points: 14.2
ceiling: 45
weight: 45
share: 31.5
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [1]
key: warranty
label: Warranty term
value: 10
unit: Unknown
shown: 10 years
shown detail: Unknown
state: documented
points: 12
ceiling: 30
weight: 30
share: 40
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 60
unit: Unknown
shown: 60 W
shown detail: Unknown
state: documented
points: 0.2
ceiling: 10
weight: 10
share: 1.7
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Sol-Ark datasheet (Sol-Ark · manufacturer · observed Sep 15, 2026)
  2. Sol-Ark 8K-2P-N installation manual (SK140-0005-002) (Sol-Ark · manufacturer · SK140-0005-002 · observed Sep 25, 2026)
  3. SanTan Solar product page: Sol-Ark 8K Hybrid Solar Inverter System (captured October 15, 2026) Paid link (SanTan Solar · seller · observed Oct 15, 2026)

Sign in to report an error on this page