| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 32 kg / 71 lb converted | Printed as 32 kg (70.5 lb). Where: PDF page 9, 8K-2P-L data sheet, General Data | [1] |
| MPPT count | 2 | The number of MPP trackers. Where: PDF page 9, 8K-2P-L data sheet, Input Data (PV) | [1] |
| Peak output | 12,000 VA for 5 s (off-grid, 240 V) | The off-grid peak apparent power for 5 seconds at 240 V. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) | [1] |
| AC voltage | 120/240 V; 120/208 V; 220 V | The nominal AC voltage row. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) | [1] |
| Max charge | 190 A | Printed as 190 A, software limited to 185 A, for charge and discharge. Where: PDF page 9, 8K-2P-L data sheet, Battery Input Data (DC) | [1] |
| Dimensions | W 420 × H 670 × D 233 mm / W 16.5 × H 26.4 × D 9.17 in converted | Printed as 670 x 420 x 233 mm (H x W x D). Where: PDF page 9, 8K-2P-L data sheet, General Data | [1] |
| Efficiency | 97.6 % | The maximum efficiency. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) | [1] |
| MPPT voltage | 100 to 500 V | Printed as 100 to 500 V (optimum 370 V). Where: PDF page 9, 8K-2P-L data sheet, Input Data (PV) | [1] |
| Solar array | 10.4 kWConverted: 10400 W / 1000 W/kW | The maximum allowed PV power (STC), printed as 10,400 W. Where: PDF page 9, 8K-2P-L data sheet, Input Data (PV) SourcesConverted: 10400 W / 1000 W/kW | [1] |
| Max discharge | 190 A | Printed as 190 A, software limited to 185 A, for charge and discharge. Where: PDF page 9, 8K-2P-L data sheet, Battery Input Data (DC) | [1] |
| Enclosure rating | IP65 / NEMA 3R | The enclosure row. Where: PDF page 9, 8K-2P-L data sheet, General Data | [1] |
| Max PV current | 18 A | Per MPPT, self-limiting. Where: PDF page 9, 8K-2P-L data sheet, Input Data (PV) | [1] |
| Max PV voltage | 500 V | Printed as 500 V with footnote 1, which bases the highest input voltage on the array's open-circuit voltage at the minimum design temperature. Where: PDF page 9, 8K-2P-L data sheet, Input Data (PV) | [1] |
| Transfer time | 4 ms | The backup transfer time. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) | [1] |
| Nominal voltage | 48 V | The nominal battery DC voltage. Where: PDF page 9, 8K-2P-L data sheet, Battery Input Data (DC) | [1] |
| Grid passthrough | 63 A | Printed as 63 A, software limited to 50 A. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) | [1] |
| Idle consumption | 60 W | The no-load idle consumption. Where: PDF page 9, 8K-2P-L data sheet, General Data | [1] |
| Max parallel units | 9 count | Printed as stackable up to 9 in parallel. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) | [1] |
| PV start voltage | 125 V | The PV startup voltage. Where: PDF page 9, 8K-2P-L data sheet, Input Data (PV) | [1] |
| PV strings per MPPT | 2 | The number of PV strings per MPPT. Where: PDF page 9, 8K-2P-L data sheet, Input Data (PV) | [1] |
| Certification claims | UL1741-2010/2018; IEEE1547a 2003/2014 | Standards printed in the certifications and listings row. Manufacturer claims, no issuer directory was checked. Where: PDF page 9, 8K-2P-L data sheet, Protection and Certifications | [1] |
| Continuous output | 8 kWConverted: 8000 W / 1000 W/kW | Printed as 8,000 W maximum continuous real power. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) SourcesConverted: 8000 W / 1000 W/kW | [1] |
| Max output current | 33.4 A | The maximum output current. Where: PDF page 9, 8K-2P-L data sheet, Output Data (AC) | [1] |
| Battery voltage range | 40 to 60 V | The battery operating voltage range. Where: PDF page 9, 8K-2P-L data sheet, Battery Input Data (DC) | [1] |
| Operating temperature | -25 to 55 °C / -13 to 131 °F converted | Printed as -25 to 55 °C ambient, derating above 45 °C. Where: PDF page 9, 8K-2P-L data sheet, General Data | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Standard Warranty 10 Years".
60 against 1 W, the lowest documented for an inverter in the 7 to 15 kW output band (printed by the maker): Fronius Primo 11.4-1 208-240. The bar is a printed bound: less than 1 W, as printed.
The no-load idle consumption.
Research pending, 0 points: Certificates, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 10 years | Printed as "Standard Warranty 10 Years". Where: PDF page 9, 8K-2P-L data sheet, General Data | [1] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Captured Nov 2, 2026 (archived copy).
Location: PDF page 9, 8K-2P-L data sheet
Retrieved Nov 2, 2026
Sol-Ark's 8K-2P-L installation manual in English (SK140-0013-001), which holds the 8K-2P-L data sheet on its PDF page 9, listed in the Sol-Ark document library (8K-2P-L Installation Manual) and fetched directly from sol-ark.com with the paced research fetcher on November 3, 2026 (robots.txt checked first; request ended 04:01:06.741 UTC). Manufacturer claims, not independent tests.
Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2025/07/SK140-0013-001-8K-2P-L_Installation-Manual-EN.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 0b346392991c16a78a997e17cc32f64707c5b96f115d9d0e764d12a84073bb4e
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2025/07/SK140-0013-001-8K-2P-L_Installation-Manual-EN.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 0b346392991c16a78a997e17cc32f64707c5b96f115d9d0e764d12a84073bb4e
No sourced accessories or replacement parts listed yet.
Printed as "Inverter Model: Sol-Ark-8K-120/230V SKU: 8K-2P-L" in the heading of the 8K-2P-L data sheet (installation manual SK140-0013-001, PDF page 9).
[1]Manufacturer SKU 8K-2P-L
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 40 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: 60 unit: Unknown shown: 60 W shown detail: Unknown state: documented points: 0.2 ceiling: 10 weight: 10 share: 1.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details