Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Sol-Ark 5K-2P-N, the front view from the "1.2 Specifications" drawing of Sol-Ark's 5K-2P-N installation guide and user manual (SK140-0007-002), cropped to the outline of the enclosure, so the brackets on its sides are outside the crop. A short end of a dimension extension line remains along the right edge beside the right foot. Figure from the manufacturer's document, page 8.Hybrid inverter
Sol-Ark 5K-2P-N
Key specs
Converted: 5,000 W / 1000 = 5 kW
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 35.4 kg / 78 lb converted Check note | Weight differs. The 5K-2P-N installation manual (SK140-0007-002) prints 35.4 kg / 78 lb; another Sol-Ark document on file prints 61.2 kg. Printed as "Weight 35.4 kg / 78 lb." in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Revised on 26 September 2026: The exact-model installation manual is the primary source (owner ruling of September 26, 2026); the previously recorded value from another Sol-Ark document is kept beside it.Where: Embedded datasheet, General Data Sources61.2 kg Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "61.2 Kg / 135 lb.". Conditions as stated on that sheet. No value was taken from another model or from a name. [1] | [2] |
| MPPT count | 2 | Printed as "No. of MPP Trackers 2" in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. Where: Datasheet, Input Data (PV), "No. of MPP Trackers" row | [1] |
| Peak output | 16,000 VA for 10 s; 25,000 VA for 100 ms (off-grid, at 240 V) | Printed as "Peak Apparent Power (10s, off-grid)" 16,000VA @ 240V and "Peak Apparent Power (100ms, off-grid)" 25,000VA @ 240V in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. Stated in VA, not W. Where: Datasheet, Output Data (AC), "Peak Apparent Power" rows | [1] |
| AC voltage | 240 V | Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "120/240V, 120/208V, 220V". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 1, "Nominal AC Voltage" row | [1] |
| Max charge | 120 A | Printed as "Max. Battery Charge / Discharge Current 120A" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Battery Input Data (DC) | [2] |
| PV wire size | 12 to 10 AWG (MPPT, 25 A DC) | Printed as "MPPT 25A DC 12 - 10 AWG" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), section 1.3, Connection Requirements, captured on September 26, 2026. Where: Section 1.3, Connection Requirements | [2] |
| Dimensions | W 450 × H 750 × D 254 mm / W 17.7 × H 29.5 × D 10 in converted Check note | Dimensions differ. The 5K-2P-N installation manual (SK140-0007-002) prints 750 x 450 x 254 mm (H x W x D); another Sol-Ark document on file prints 494 x 807 x 306 mm. Printed as "Dimensions (H x W x D) 750 x 450 x 254 mm (29.5 x 17.7 x 10 in)" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Revised on 26 September 2026: The exact-model installation manual is the primary source (owner ruling of September 26, 2026); the previously recorded value from another Sol-Ark document is kept beside it.Where: Embedded datasheet, General Data SourcesW 807 × H 494 × D 306 mm Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "807 x 494 x 306 mm (31.8 x 19.4 x 12 in)". Conditions as stated on that sheet. No value was taken from another model or from a name. [1] | [2] |
| Communications | CANBus; RS485 MODBUS; Wi-Fi; LAN | Printed as "BMS Communication CANBus & RS485 MODBUS" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. The same page prints "Communication and Monitoring Wi-Fi & LAN Hardware Included". Where: Embedded datasheet | [2] |
| Efficiency | 97.5 % | Printed as "Max Efficiency 97.5%" in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026; the same section prints "CEC Efficiency 96.5%". Manufacturer rating; no test conditions are given. Where: Datasheet, Output Data (AC), "Max Efficiency" row | [1] |
| MPPT voltage | 150 to 500 | Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "150 - 500V". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 1, "MPPT Voltage Range" row | [1] |
| Solar array | 6.5 kWConverted: 6,500 W / 1000 = 6.5 kW | Printed as "Max. Allowed PV Power (STC) 6,500W" in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. The largest PV array Sol-Ark allows at STC. Where: Datasheet, Input Data (PV), "Max. Allowed PV Power (STC)" row SourcesConverted: 6,500 W / 1000 = 6.5 kW | [1] |
| AC frequency | 50 / 60 Hz | Printed as "Grid Frequency 50 / 60Hz" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Output Data (AC) | [2] |
| Max discharge | 120 A | Printed as "Max. Battery Charge / Discharge Current 120A" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Battery Input Data (DC) | [2] |
| Enclosure rating | IP65 | Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "IP65 / NEMA 3R". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 1, "Enclosure" row | [1] |
| Max PV current | 10 A | Printed as "Max. Operating Input Current per MPPT 10A (self-limiting)" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Input Data (PV) | [2] |
| Max PV voltage | 500 V | Printed as "Max. Input Voltage 500V" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Input Data (PV) | [2] |
| Transfer time | 4 ms | Printed as "Backup Transfer Time 4ms" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Output Data (AC) | [2] |
| Battery wire size | 2/0 to 4/0 AWG (battery port, 185 A DC) | Printed as "Battery Port 185A DC 2/0 - 4/0 AWG" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), section 1.3, Connection Requirements, captured on September 26, 2026. Where: Section 1.3, Connection Requirements | [2] |
| Generator support | Automatic Generator Start (AGS), 2 Wire Start, integrated | Printed as "Automatic Generator Start (AGS) 2 Wire Start - Integrated" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Battery Input Data (DC) | [2] |
| Nominal voltage | 48 V | Printed as "Nominal DC Voltage 48V" in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026; the operating range is printed as 43 - 63V. Where: Datasheet, Battery Input Data (DC), "Nominal DC Voltage" row | [1] |
| PV efficiency | 97.5 % | Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "97.5%". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 1, "Max Efficiency" row | [1] |
| AC input wire size | 6 to 4 AWG (GRID, 63 A AC) | Printed as "GRID 63A AC 6 - 4 AWG" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), section 1.3, Connection Requirements, captured on September 26, 2026. Runs should be sized for at or below 2.5% voltage drop at full load. Where: Section 1.3, Connection Requirements | [2] |
| Grid passthrough | 63 A | Printed as "Max. Grid Passthrough Current 63A" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Output Data (AC) | [2] |
| Idle consumption | 60 W | Printed as "Idle consumption - No Load 60W" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, General Data | [2] |
| PV start voltage | 125 V | Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "125V". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 1, "Startup Voltage" row | [1] |
| Terminal torque | 10 N·m | Printed as "Battery Connection 90 in-lb 10 Nm" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), torque table, captured on September 26, 2026. Where: Section 1, Torque table | [2] |
| AC output wire size | 6 to 4 AWG (LOAD, 63 A AC) | Printed as "LOAD 63A AC 6 - 4 AWG" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), section 1.3, Connection Requirements, captured on September 26, 2026. Where: Section 1.3, Connection Requirements | [2] |
| Operating noise | 30 dBA < 30 dB as printed | Printed as "Noise < 30 dB @ 25°C (77°F)" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Printed as an upper bound in dB. Where: Embedded datasheet, General Data | [2] |
| PV strings per MPPT | 2 | Printed as "No. of PV Strings per MPPT 2" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Input Data (PV) | [2] |
| Continuous output | 5 kWConverted: 5,000 W / 1000 = 5 kW | Printed as "Real Power, max continuous 5,000W" in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. Where: Datasheet, Output Data (AC), "Real Power, max continuous" row SourcesConverted: 5,000 W / 1000 = 5 kW | [1] |
| Battery compatibility | Lithium / Lead Acid | Printed as "Battery Technologies Lithium / Lead Acid" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Battery chemistries only; no battery models are listed there. Where: Embedded datasheet, Battery Input Data (DC) | [2] |
| Battery voltage range | 43 to 63 V | Printed as "Operating Voltage Range 43 - 63V" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026. Where: Embedded datasheet, Battery Input Data (DC) | [2] |
| Operating temperature | -25 to 55 °C / -13 to 131 °F converted | Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "-25~55°C, > 45°C Derating". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 1, "Ambient Temperature" row | [1] |
| Other compliance claims | CA Rule 21, HECO Rule 14H | Listed in the Protection and Certifications section of the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026, after the numbered standards recorded as certification claims. Utility interconnection rules Sol-Ark lists; no certificate or issuer record is given. Where: Datasheet, Protection and Certifications | [1] |
| Weighted efficiency | 96.5 % | Read from Sol-Ark's published document at https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf, from a document that names 5K-2P-N and no other model in this catalog. Printed value: "96.5%". Conditions as stated on that sheet. No value was taken from another model or from a name. Where: PDF page 1, "CEC Efficiency" row | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- Continuous output
- 5 kW
- Battery voltage
- 43 to 63 V
- Solar input
- 6.5 kWMPPT trackers 2MPPT range 150 to 500 V
- AC output
- 240 V
- Warranty
- 10 years
- Size
- 85.72 L* (Calculated from published dimensions)W: 450 × H: 750 × D: 254 mm / W: 17.7 × H: 29.5 × D: 10 inWeight 35.4 kg / 78 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Standard Warranty 10 Years" in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. No separate warranty document for this model was read.
60 against 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band (printed by the maker): Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.
Printed as "Idle consumption - No Load 60W" in the Sol-Ark 5K-2P-N installation manual (SK140-0007-002), embedded datasheet, captured on September 26, 2026.
Research pending, 0 points: Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
How it worksCertificates
FCC 15 Class Bmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- 5K-2P-N
- Limitations
- Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "FCC 15 Class B".
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
IEEE 1547a 2003/2014manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- 5K-2P-N
- Limitations
- Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "IEEE1547a 2003/2014".
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741-2010/2018manufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- 5K-2P-N
- Limitations
- Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741-2010/2018".
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
UL 1741 SBmanufacturer claimpresent at observation[1]
- Scope
- equipment listing
- Covered models
- 5K-2P-N
- Limitations
- Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741SB".
- Record detail
- Issued: Not statedValid from: Not statedExpiry: Not statedNot checked
- Source
- [1]
Warranty
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 10 years | Printed as "Standard Warranty 10 Years" in the Sol-Ark 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. No separate warranty document for this model was read. Where: Datasheet, General Data, "Standard Warranty" row | [1] |
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Manuals
- Sol-Ark 5K-2P-N installation manual (SK140-0007-002)Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-26.
Location: Section 1, embedded datasheet and Connection Requirements
Retrieved Sep 25, 2026
Sol-Ark's own installation manual for the 5K-2P-N, listed in its Product Document Library and captured on September 26, 2026. Includes an embedded datasheet page; manufacturer claims, not a certificate.
Archived copies
Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupSK140-0007-002 · 7.39 MBArchived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/06/5K-2P-N_Manual_EN_5May2025-1-1.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 759ca07ffded8018dcb7cbd8dcc554246d55ac4fa3f9739da5e726d60d829abb
Datasheets
- Sol-Ark datasheetOpen
Certificate & compliance claims (4)
UL 1741-2010/2018Manufacturer claim · equipment listingClaimedListed when checked
Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741-2010/2018".
Manufacturer document
Official datasheet: Sol-Ark datasheetIEEE 1547a 2003/2014Manufacturer claim · equipment listingClaimedListed when checked
Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "IEEE1547a 2003/2014".
Manufacturer document
Official datasheet: Sol-Ark datasheetFCC 15 Class BManufacturer claim · equipment listingClaimedListed when checked
Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "FCC 15 Class B".
Manufacturer document
Official datasheet: Sol-Ark datasheetUL 1741 SBManufacturer claim · equipment listingClaimedListed when checked
Listed on the certifications line of Sol-Ark's own 5K-2P-N datasheet PS-00034 Rev. 2, captured on September 25, 2026. A manufacturer claim: no certificate number, file number or issuer is printed on the datasheet and no issuer record was read. Printed as "UL1741SB".
Manufacturer document
Official datasheet: Sol-Ark datasheetSource details
Identity at specified physical page; specifications only where separately field-cited
Location: PDF page 1
Retrieved Sep 15, 2026
SHA-256: cd862843e60630facc2d6a182ca638989829126705bb4ae6f0804eda2f0b4243
Archived copies
Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupRevision not recorded · 0.15 MBArchived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cd862843e60630facc2d6a182ca638989829126705bb4ae6f0804eda2f0b4243
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Sol-Ark datasheet
Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/05/SK150-0007_5K-2P-Datasheet-Rev-2_19June2025.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: cd862843e60630facc2d6a182ca638989829126705bb4ae6f0804eda2f0b4243
Sol-Ark 5K-2P-N installation manual (SK140-0007-002)
Archived copy of a document published by Sol-Ark. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Sol-Ark published. Original address: https://sol-ark.com/wp-content/uploads/2024/06/5K-2P-N_Manual_EN_5May2025-1-1.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 759ca07ffded8018dcb7cbd8dcc554246d55ac4fa3f9739da5e726d60d829abb
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- 5K-2P-N
No historical observations recorded yet.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 85 basis: Unknown missing: Battery conversion efficiency needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741 SB · UL 1741-2010/2018 +2 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [1] key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: 60 unit: Unknown shown: 60 W shown detail: Unknown state: documented points: 0.2 ceiling: 10 weight: 10 share: 1.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [2] | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Sol-Ark datasheet (Sol-Ark · manufacturer · observed Sep 15, 2026)
- Sol-Ark 5K-2P-N installation manual (SK140-0007-002) (Sol-Ark · manufacturer · SK140-0007-002 · observed Sep 25, 2026)
Sign in to report an error on this page
Similar products
All with a priceRICH SOLAR NOVA 6500S
RICH SOLAR NOVA 6548 - NOVA 6548
RICH SOLAR NOVA 6K
SunGoldPower SGN7.6K1HB-48
* Missing details