AC output
- Continuous output
- 4.8 kW [1]
- Peak output
- 7,200 VA for 5 s (off-grid) [2]
- AC configuration
- 120 V single phase; separate 240 V configuration has different ratings [2]
- AC output voltage
- 120 V [2]
- AC frequency
- ?
- Grid pass-through
- 50 A [2]
- Maximum output per leg
- ?
Battery
- Battery voltage range
- 40 to 60 [2]
- Maximum charge current
- 120 A [2]
- Maximum discharge current
- 120 A [2]
- Battery-only output
- ?
- Maximum grid charging
- ?
- Compatible batteries / BMS
- ?
PV input
- PV array limit (connected)
- 10.4 kW [2]
- PV input limit (converted)
- ?
- Maximum PV voltage (Voc)
- 500 V [2]
- MPPT voltage range
- 150 to 425 [2]
- String inputs per MPPT
- ?
- PV current per MPPT
- 26 A [2]
- PV short-circuit current
- ?
- PV startup voltage
- 125 V [2]
Efficiency and modes
- Peak efficiency
- 97.6 % [2]
- CEC weighted efficiency
- ?
- Battery conversion efficiency
- ?
- Grid / off-grid modes
- ?
- Generator input
- ?
- Transfer time
- ?
- Parallel units
- ?
Communication and environment
- Communications
- ?
- Operating temperature
- -40 to 60 °C / -40 to 140 °F converted [2]
- Enclosure rating
- IP65; NEMA3R [2]
- Operating noise
- ?
Mechanical
- Dimensions
- W 330 × H 600 × D 237 mm / W 13 × H 23.6 × D 9.33 in converted [2]
- Weight
- 24 kg / 53 lb converted [2]
Installation (from the manual)
Torque
- Terminal torque
- 4.5 N·m [1]
- AC terminal torque
- ?
- Battery terminal torque
- ?
- PV terminal torque
- ?
- Ground terminal torque
- ?
Conductors
- Battery conductors
- 2/0 AWG THHN [1]
- AC output conductors
- 8 AWG to 6 AWG (LOAD terminal, 50 A) [1]
- PV conductors
- ?
- Ground conductor
- ?
Not in the manual: Protection, Clearances and orientation, Grounding, Communication