Charged ReviewsSaved 0Compare 0Login
Sigineer Power M6048DUL 6000W 48V Split Phase Off Grid Solar Inverter Charger
Sigineer Power
Off-grid inverter

Sigineer Power M6048DUL 6000W 48V Split Phase Off Grid Solar Inverter Charger

Key specs

Continuous output6 kW
Weight45 kg / 99 lb converted
Nominal voltage48 V
Efficiency85 % Check note
Surge AC output12,000 W Check note
AC voltage120/240 V AC split phase; adjustable to 104/208, 110/220, 115/230 or 120/240 V AC

All specifications

Identity

BrandSigineer Power · Website
ModelM6048DUL
MarketUS
Manufacturer SKUM6048DUL
About brandSigineer Power (Sigineer Power Limited, according to its manuals) makes low frequency inverter chargers and off grid solar inverters, sold from sigineer.com with a US warehouse in Phoenix, Arizona; its M6048DUL product page says its ETL listing appears in Intertek's directory under the manufacturer name Dongguan Sigineer Power Electrical Technology Co., Ltd.
SKU detail
locator: Product page, Model # and SKU; manual charging current table and spec sheet
conditions: The product page prints "Model #: M6048DUL" and "SKU: M6048DUL"; the manual prints the model in its charging current table, idle table and spec sheet.
Sources: [1] [2]
FieldValueConditionsSource
Phase120/240V split phase
The manual's cover prints "(4KW - 12KW 48Vdc 120/240Vac Split Phase)" for the series; the product page prints "Pure Sine Wave AC Output 6000 Watt 120/240Vac Split Phase".
Where: Manual cover; product page FEATURES
[2] [1]
Weight45 kg / 99 lb converted
The manual prints "Net Weight 38kg/84lbs 41kg/90lbs 45kg/99lbs" (first three columns); 45kg/99lbs in the M6048DUL column. The product page prints "Unit Weight: 99lbs/45KG".
Where: PDF page 42 (printed page 42), Appendix 1 spec sheet, Mechanical Specifications, Net Weight, M6048DUL column (third of six)
[2] [1]
Peak output12 kW for 5 seconds; 18 kW for 20 ms
The manual prints "Surge Rating (5sec) 8KW 10KW 12KW 16KW 20KW 24KW Surge Rating (20ms) 12KW 15KW 18KW 24KW 30KW 36KW"; the M6048DUL column reads 12KW (5sec) and 18KW (20ms). The product page prints "Surge Rating: 18000 Watts (5 Seconds)", which differs from the manual's 5 second figure.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Surge Rating (5sec) and Surge Rating (20ms), M6048DUL column (third of six)
[2]
AC voltage120/240 V AC split phase; adjustable to 104/208, 110/220, 115/230 or 120/240 V AC
The product page prints "Output Voltage: 104/208V, 110/220V, 115/230V, 120/240Vac (Resetable)". The manual prints the line-to-line value only, "Nominal Output Voltage 208V-220V-230V-240Vac (+/-10% RMS) Adjustable", for every model.
Where: Product page, Inverter Output Specifications, Output Voltage; manual Appendix 1, Nominal Output Voltage
[1] [2]
Max charge140 A
The manual's table "Model # AC Charging Current MPPT Solar Charger Max Charging Current" prints "M6048DUL 60A 80A 140A": 60 A AC charging, 80 A MPPT solar charging and 140 A maximum combined charging current. The product page prints "Max Combined Charge Rate: 140Amp".
Where: PDF page 13, charging current table, M6048DUL row
[2] [1]
DimensionsW 540 × H 360 × D 218 mm / W 21.3 × H 14.2 × D 8.58 in converted
The manual prints "Unit Dimensions (W*H*D) 540*360*218mm / 21.2*14.2*8.6”", a cell the rendered page shows spanning the M4048DUL to M6048DUL columns. The product page prints the same millimeters under another label, "Unit Size L x W x H: 540*360*218mm/21.2*14.2*8.7″".
Where: PDF page 42 (printed page 42), Appendix 1 spec sheet, Mechanical Specifications, Unit Dimensions (W*H*D)
[2] [1]
CommunicationsRS485; USB; Wi-Fi or GPRS module
The manual lists four ways to monitor the inverter: the remote LCD panel on the RS485 port, a computer on the USB port, a Wi-Fi or GPRS module in the Wi-Fi port, and the RS485 port with the same protocol.
Where: PDF page 15, 2.4.6 Remote Monitoring
[2]
Efficiency85 % Check note
>85% (peak) as printed
The product page prints a higher peak efficiency. Sigineer Power's M Series DUL manual prints a peak inverter efficiency of >85%; the M6048DUL product page prints 91% (peak). The manual value is recorded.
The manual prints "Inverter Efficiency(Peak) >85%" for every model, a lower bound at peak, and "Line Mode Efficiency >95%"; the figure is kept as a bound.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Inverter Efficiency(Peak)
Sources
91 %

The product page prints "Nominal Efficiency: 91% (Peak)".

[1]
[2]
MPPT voltage60 to 245 V
The manual prints "MPPT Operating Voltage 60-245Vdc" for every model.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, MPPT Operating Voltage
[2]
Solar input5 kW
Converted: 5000 W / 1000 = 5 kW
The manual prints "Maximum PV Input Power 5000W 7000W"; the rendered page shows the 5000W cell spanning the M4048DUL to M6048DUL columns. 5000 W expressed in kW.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, 48V MPPT Solar Charger, Maximum PV Input Power
Sources
Converted: 5000 W / 1000 = 5 kW
[2]
AC frequency50 Hz or 60 Hz (±0.3 Hz), adjustable
The manual prints "Output Frequency 50Hz/60Hz(+/-0.3 Hz) Adjustable"; the product page prints "Output Frequency: 50Hz +/- 0.3Hz / 60Hz +/- 0.3Hz".
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Output Frequency
[2] [1]
Max AC charge60 A
The manual prints "M6048DUL 60A 80A 140A" (AC charging current first) and "Maximum Charge Current 40A 50A 60A 70A 80A 100A" (60A in the M6048DUL column); the product page prints "AC Charger Rate: 60Amp". The page's feature list also prints "Smart AC to DC Battery Charger 100 Amp", which its own specification block and the manual do not support for this model; it is not used.
Where: PDF page 13, charging current table, M6048DUL row; PDF page 41 (printed page 41), Appendix 1 spec sheet, AC Input, Maximum Charge Current, M6048DUL column (third of six)
[2] [1]
Max PV charge80 A
The manual prints "M6048DUL 60A 80A 140A" (80 A MPPT solar charger) and "Maximum PV Charge Current 80A 120A", a cell the rendered page shows spanning the M4048DUL to M6048DUL columns; the product page prints "Solar Charger Rate: 80Amp PV Voc 250V".
Where: PDF page 13, charging current table, M6048DUL row; PDF page 41 (printed page 41), Appendix 1 spec sheet, 48V MPPT Solar Charger, Maximum PV Charge Current
[2] [1]
Output waveformPure sine wave
The manual prints "Waveform Pure sine wave/ same as input (bypass mode)" for every model; the product page prints "Pure Sine Wave AC Output 6000 Watt 120/240Vac Split Phase".
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Waveform
[2] [1]
AC configuration120/240 V AC split phase
The manual's cover prints "120/240Vac Split Phase"; the product page prints "Pure Sine Wave AC Output 6000 Watt 120/240Vac Split Phase".
Where: Manual cover; product page FEATURES
[2] [1]
AC input breaker63A
The manual prints "AC Input Breaker 63A 63A 63A 80A 80A 80A"; 63A in the M6048DUL column.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Bypass & Protection, AC Input Breaker, M6048DUL column (third of six)
[2]
Max PV voltage250 V
The manual prints "Max. PV Open Circuit Voltage (Voc) 250VDC" for every model; the product page prints "80A MPPT Solar Charger with PV Voc 250V".
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Max. PV Open Circuit Voltage (Voc)
[2] [1]
Transfer time10 ms
The manual prints "Typical Transfer Time 10ms"; the product page prints "Typical Transfer Time: 10ms (Max)".
Where: PDF page 41, Appendix 1 spec sheet, Typical Transfer Time
[2] [1]
AC output breaker32A
The manual prints "AC output Breaker 32A 32A 32A 63A 63A 63A"; 32A in the M6048DUL column.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Bypass & Protection, AC output Breaker, M6048DUL column (third of six)
[2]
Generator supportAutomatic generator start
The product page prints "Automatic Generator Start"; the manual's spec sheet names its bypass section "BYPASS & PROTECTION(Grid & Generator)".
Where: Product page, FEATURES
[1]
Nominal voltage48 V
The manual prints "Battery voltage 48VDC" in every column; the product page prints "Nominal Input Voltage: 48.0Vdc".
Where: PDF page 40, Appendix 1 spec sheet, Battery voltage, M6048DUL column (third of six)
[2] [1]
Surge AC output12,000 W Check note
The product page prints a higher 5 second surge. Sigineer Power's M Series DUL manual prints a 5 second surge of 12KW and a 20 ms surge of 18KW for the M6048DUL; the product page prints 18000 W for 5 seconds. The manual value is recorded.
The manual prints "Surge Rating (5sec) 8KW 10KW 12KW 16KW 20KW 24KW Surge Rating (20ms) 12KW 15KW 18KW 24KW 30KW 36KW": 12KW for 5 seconds and 18KW for 20 ms in the M6048DUL column. The 5 second figure is recorded.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Surge Rating (5sec), M6048DUL column (third of six)
Sources
18,000 W

The product page prints "Surge Rating: 18000 Watts (5 Seconds)" and "18000W Power Surge for 5 Seconds"; the manual gives 18KW only for 20 ms.

[1]
[2]
AC input voltage240 V AC nominal
The manual prints "AC INPUT Nominal Voltage 240VAC" for every model; the product page prints "Ac Input Voltage For Charger: Nominal 240Vac (154-260Vac)".
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, AC Input, Nominal Voltage
[2] [1]
Idle consumption100 W Check note
100 W max (25 W with power saver on) as printed
The product page prints a higher idle consumption. Sigineer Power's M Series DUL manual prints 100 W idle (25.0 W with power saver on) for the M6048DUL; the product page prints 120 W (30 W with power saver). The manual value is recorded.
The manual's idle table ("Model Idle(Max) 3Secs(Max)") prints "M6048DUL 100W 25.0W": 100 W maximum idle, and 25.0 W with power saver on (3 second search).
Where: PDF page 15, M Series Inverter/Charger Idle Power Consumption (in Watts), M6048DUL row
Sources
120 W

The product page prints "Idle Consumption: 120 Watts" and "Power Saver Mode Idle Consumption:30 Watts".

[1]
[2]
Shipping weight59 kg / 130 lb converted Check note
The product page prints a different shipping weight and box size. Sigineer Power's M Series DUL manual prints a gross weight of 59 kg (130 lbs) and a packing size of 740 x 550 x 460 mm for the M6048DUL; the product page prints a shipping weight of 58 kg (128 lbs) and a shipping size of 690 x 520 x 390 mm. The manual values are recorded.
The manual prints "Gross Weight 53kg/116lbs 55kg/121lbs 59kg/130lbs" (first three columns); 59kg/130lbs in the M6048DUL column. The manual's packing size for the M4048DUL to M6048DUL is "740*550*460mm / 30*21*18”"; the product page prints "Shipping Size: L x W x H:690*520*390mm/27*20*16″".
Where: PDF page 42 (printed page 42), Appendix 1 spec sheet, Mechanical Specifications, Gross Weight, M6048DUL column (third of six)
Sources
58 kg

The product page prints "Shipping Weight: 128lbs/58KG" and "Weight 128 lbs" in its Additional information table.

[1]
[2]
Certification claimsETL listed to UL 1741 and CSA C22.2 No. 107.1 (Intertek control number 5023256)
The manual prints "The M4048DUL/M5048DUL/M6048DUL/M8048DUL/M10048DUL/M12048DUL inverter models are ETL listed to below standards", naming UL 1741:2010 Ed.2+R:16Sep2020 and CSA C22.2#107.1:2016 Ed.4, and "The Sigineer Power ETL control number is 5023256." The product page prints the same control number. A claim in the maker's documents; no listing record was read.
Where: PDF page 4, 1.4 certificates; PDF page 44, Appendix 3; product page description
[2] [1]
Continuous output6 kW
The manual prints "Rated Power 4KW 5KW 6KW 8KW 10KW 12KW"; 6KW in the M6048DUL column. The product page prints "Continuous Output Power: 6000 Watts".
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Rated Power, M6048DUL column (third of six)
[2] [1]
Storage temperature-20 to 60 °C / -4 to 140 °F converted
The manual prints "Storage Temperature -20°C to 60°C / -4°F to 140°F".
Where: PDF page 42, Appendix 1 spec sheet, Operating Environment, Storage Temperature
[2]
Continuous AC output6,000 W
The manual prints 6KW in the M6048DUL column of its Rated Power row; the product page prints "Continuous Output Power: 6000 Watts".
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, Rated Power, M6048DUL column (third of six); product page, Inverter Output Specifications
[2] [1]
Operating temperature0 to 50 °C / 32 to 122 °F converted
The manual prints "Operation Temperature Range 0°C to 50°C/ 32°F to 122°F" for every model.
Where: PDF page 42, Appendix 1 spec sheet, Operating Environment, Operation Temperature Range
[2]
AC transfer switch rating63AThe product page prints "63A AC transfer switch".
Where: Product page, description
[1]
MPPT tracking efficiencyTracking 99.5%; charging 96%
The manual prints "Efficiency Tracking: 99.5%. | Charging: 96%." for every model.
Where: PDF page 41 (printed page 41), Appendix 1 spec sheet, 48V MPPT Solar Charger, Efficiency
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
6 kW
Battery voltage
48 V
Solar input
5 kWMPPT trackers Not statedMPPT range 60 to 245 V
AC output
120/240 V AC split phase
Warranty
1 year
Size
42.38 L* (Calculated from published dimensions)W: 540 × H: 360 × D: 218 mm / W: 21.3 × H: 14.2 × D: 8.58 inWeight 45 kg / 99 lb

Evidence score

12/100Missing details85% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 · CSA C22.2 No. 107.1Claimed10.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[2] [1]

Warranty term1 year1.2 / 30.0

1 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

The manual prints "We warrant this product against defects in materials and workmanship for a period of one year from the date of purchase"; the warranty excludes labor, travel and other costs. The product page prints no warranty term.

[2]

Idle consumption120 W0.1 / 10.0

120 W is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band, printed by the maker: Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.

The manual's idle table ("Model Idle(Max) 3Secs(Max)") prints "M6048DUL 100W 25.0W": 100 W maximum idle, and 25.0 W with power saver on (3 second search).

The maker's documents disagree; the less favorable printed figure, 120 W, is scored. Warning: The product page prints a higher idle consumption

[2]

Research pending, 0 points: Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CSA C22.2 No. 107.1manufacturer claimpresent at observation[2] [1]
Scope
equipment listing
Covered models
M6048DUL
Limitations
Sigineer Power's M Series DUL manual (Version 1.0, PN:80000-20250329; sections 1.4 and Appendix 3) prints that the M4048DUL, M5048DUL, M6048DUL, M8048DUL, M10048DUL and M12048DUL "are ETL listed" to CSA C22.2 No. 107.1 (printed as "[CSA C22.2#107.1:2016 Ed.4]") and that "The Sigineer Power ETL control number is 5023256"; the M6048DUL product page prints the same control number and says it can be verified in Intertek's directory under Dongguan Sigineer Power Electrical Technology Co., Ltd. Intertek's directory was not checked and no certificate or test report was read; this is the maker's claim.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2] [1]
UL 1741manufacturer claimpresent at observation[2] [1]
Scope
equipment listing
Covered models
M6048DUL
Limitations
Sigineer Power's M Series DUL manual (Version 1.0, PN:80000-20250329; sections 1.4 and Appendix 3) prints that the M4048DUL, M5048DUL, M6048DUL, M8048DUL, M10048DUL and M12048DUL "are ETL listed" to UL 1741 (printed as "[UL 1741:2010 Ed.2+R:16Sep2020]") and that "The Sigineer Power ETL control number is 5023256"; the M6048DUL product page prints the same control number and says it can be verified in Intertek's directory under Dongguan Sigineer Power Electrical Technology Co., Ltd. Intertek's directory was not checked and no certificate or test report was read; this is the maker's claim.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[2] [1]

Warranty

FieldValueConditionsSource
Warranty term1 years
The manual prints "We warrant this product against defects in materials and workmanship for a period of one year from the date of purchase"; the warranty excludes labor, travel and other costs. The product page prints no warranty term.
Where: PDF page 40, 5 Warranty
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Off Grid Solar Inverter Charger User's Manual (4KW - 12KW 48Vdc 120/240Vac Split Phase), Version 1.0, PN:80000-20250329 (Sigineer Power)Official · Sigineer Power · Official user manual · PDF
    Certificate & compliance claims (2)
    UL 1741Manufacturer claim · equipment listingClaimedListed when checked

    Sigineer Power's M Series DUL manual (Version 1.0, PN:80000-20250329; sections 1.4 and Appendix 3) prints that the M4048DUL, M5048DUL, M6048DUL, M8048DUL, M10048DUL and M12048DUL "are ETL listed" to UL 1741 (printed as "[UL 1741:2010 Ed.2+R:16Sep2020]") and that "The Sigineer Power ETL control number is 5023256"; the M6048DUL product page prints the same control number and says it can be verified in Intertek's directory under Dongguan Sigineer Power Electrical Technology Co., Ltd. Intertek's directory was not checked and no certificate or test report was read; this is the maker's claim.

    Manufacturer document

    Official user manual: Off Grid Solar Inverter Charger User's Manual (4KW - 12KW 48Vdc 120/240Vac Split Phase), Version 1.0, PN:80000-20250329 (Sigineer Power)
    CSA C22.2 No. 107.1Manufacturer claim · equipment listingClaimedListed when checked

    Sigineer Power's M Series DUL manual (Version 1.0, PN:80000-20250329; sections 1.4 and Appendix 3) prints that the M4048DUL, M5048DUL, M6048DUL, M8048DUL, M10048DUL and M12048DUL "are ETL listed" to CSA C22.2 No. 107.1 (printed as "[CSA C22.2#107.1:2016 Ed.4]") and that "The Sigineer Power ETL control number is 5023256"; the M6048DUL product page prints the same control number and says it can be verified in Intertek's directory under Dongguan Sigineer Power Electrical Technology Co., Ltd. Intertek's directory was not checked and no certificate or test report was read; this is the maker's claim.

    Manufacturer document

    Official user manual: Off Grid Solar Inverter Charger User's Manual (4KW - 12KW 48Vdc 120/240Vac Split Phase), Version 1.0, PN:80000-20250329 (Sigineer Power)
    Source details
    Revision
    Version 1.0 (PN:80000-20250329)
    Revision date
    Not stated

    Archived copy captured on 2026-10-17.

    Location: Cover; 1.4 certificates (PDF page 4); charging current table (PDF page 13); idle table (PDF page 15); 5 Warranty and Appendix 1 spec sheet (PDF pages 40 to 42); Appendix 3 (PDF page 44)

    Retrieved Oct 16, 2026

    Sigineer Power's user manual for its M Series DUL off grid solar inverter chargers (M4048DUL, M5048DUL, M6048DUL, M8048DUL, M10048DUL and M12048DUL), Version 1.0 (PN:80000-20250329), served from sigineer.com, captured on October 17, 2026. Its Appendix 1 spec sheet (PDF pages 40 to 42) has one column per model; only the M6048DUL column (the third) is read, and a value printed once across merged columns is read only where the rendered page shows the merged cell spanning the M6048DUL column (the M4048DUL to M6048DUL cells for PV charge current, PV input power, unit dimensions and packing size). Its charging current table (PDF page 13) and idle consumption table (PDF page 15) list each model by name. The product label for the M6048DUL on PDF page 42 is an image without a text layer, so nothing is read from it. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by Sigineer Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupRevision not recorded · 3.39 MB

    Archived copy, unaltered, kept as a record of what Sigineer Power published. Original address: https://sigineer.com/wp-content/uploads/2026/08/Sigineer-Power-M6048DUL-M12048DUL-Solar-Inverter-Manual-20250329.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    45

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 079ab288cd3f34cc22bbfc41c96d02c3abddb4b3066ce51a427a0258072df819

    Open
  • Other documents

  • Sigineer Power M6048DUL product page, 6000W 48V to 120/240V split phase off grid solar inverter (October 17, 2026 capture)Official · Sigineer Power · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-17.

    Location: Description (Model #, SKU, FEATURES, SPECIFICATIONS); Additional information

    Retrieved Oct 16, 2026

    Sigineer Power's own store page for the M6048DUL on sigineer.com, captured on October 17, 2026; the content is whatever the address served on that date. It prints "Model #: M6048DUL" and "SKU: M6048DUL", a feature list and a SPECIFICATIONS block, and an Additional information table with the boxed weight and size. Its Buyer Videos section embeds customer videos, one titled with "M6048D"; nothing is read from the videos. The page carries no revision date. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Off Grid Solar Inverter Charger User's Manual (4KW - 12KW 48Vdc 120/240Vac Split Phase), Version 1.0, PN:80000-20250329 (Sigineer Power)

Archived copy of a document published by Sigineer Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 3.39 MB

Archived copy, unaltered, kept as a record of what Sigineer Power published. Original address: https://sigineer.com/wp-content/uploads/2026/08/Sigineer-Power-M6048DUL-M12048DUL-Solar-Inverter-Manual-20250329.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
45

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 079ab288cd3f34cc22bbfc41c96d02c3abddb4b3066ce51a427a0258072df819

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
M6048DUL

Manufacturer SKU M6048DUL · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 85
basis: Unknown
missing:
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 22.75
unit: Unknown
shown: UL 1741 · CSA C22.2 No. 107.1
shown detail: Claimed
state: claimed
points: 10.2
ceiling: 45
weight: 45
share: 22.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [2] [1]
key: warranty
label: Warranty term
value: 1
unit: Unknown
shown: 1 year
shown detail: Unknown
state: documented
points: 1.2
ceiling: 30
weight: 30
share: 4
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 120
unit: Unknown
shown: 120 W
shown detail: Unknown
state: documented
points: 0.1
ceiling: 10
weight: 10
share: 0.8
covered: yes
missing: no
folded: no
reason: documents-disagree
reason text: The maker's documents disagree; the less favorable printed figure, 120 W, is scored. Warning: The product page prints a higher idle consumption
note:
display note: Unknown
Sources: [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Sigineer Power M6048DUL product page, 6000W 48V to 120/240V split phase off grid solar inverter (October 17, 2026 capture) (Sigineer Power · manufacturer · observed Oct 16, 2026)
  2. Off Grid Solar Inverter Charger User's Manual (4KW - 12KW 48Vdc 120/240Vac Split Phase), Version 1.0, PN:80000-20250329 (Sigineer Power) (Sigineer Power · manufacturer · observed Oct 16, 2026)

Sign in to report an error on this page