Schneider Electric Conext SW 4048 230 (865-4048-61)

Key specs

Weight34.5 kg / 76.1 lb converted
Nominal voltage48 V DC
Efficiency94 %
Continuous output3.8 kW
Converted: 3800 W / 1000 W per kW = 3.8 kW
Max charge45 A
AC frequency50 or 60 Hz (selectable); 50 Hz default

All specifications

Identity

BrandSchneider Electric · Website
ModelConext SW 4048 230
MarketUnknown
Manufacturer SKU865-4048-61
SKU detail
locator: Cover and Copyright and Contact page, Product Part Numbers line
conditions: Part number as printed by Schneider Electric on the covers of the July 2015 owner's guide (975-0636-01-01 Rev E) and installation guide (975-0637-01-01 Rev E) for the 230 V models.
Sources: [1] [2]
FieldValueConditionsSource
Weight34.5 kg / 76.1 lb converted
Printed as "34.5 kg" net weight. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Physical Specifications, Net Weight row
[1] [2]
Peak output4400 W for 30 min; 7000 W for 5 s
Printed as 4400 W for 30 minutes (only when NoLoadVD is enabled) and 7000 W 5-second surge, at 25 °C. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Output power (AC) rows
[1] [2]
AC voltage240 VAC Check note
The model name and other rows say 230 V. Both Rev E guides print the SW 4048 230's nominal output voltage as 240 VAC, while the model is named "Conext SW 4048 230", the SW 2524 230 and SW 4024 230 columns print 230 VAC, and the AC input voltage row prints 230 VAC for all three models. The printed 240 VAC is recorded.
Printed as nominal voltage "240 VAC" in the SW 4048 230 column (read from the rendered page 6-2 of the owner's guide), with an operating voltage range of 219–240 VAC. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Nominal voltage row
[1] [2]
Max charge45 A
Printed as "45 A" maximum charger output current. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Charger Specifications, Maximum output current row
[1] [2]
DimensionsW 343 × H 197 × L 387 mm / W 13.5 × H 7.76 × L 15.2 in converted
Printed as "387×343×197 mm" (L × W × H). Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Physical Specifications, L × W × H row
[1] [2]
Efficiency94 %
Peak inverter efficiency, printed as "94%". Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Peak efficiency row
[1] [2]
AC frequency50 or 60 Hz (selectable); 50 Hz default
Printed as operating frequency range "selectable 50 or 60 Hz" and default output frequency "50 Hz". Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Operating frequency range and Default output frequency rows
[1] [2]
AC configurationSingle-phase (L, N, earth)
Printed as AC OUTPUT connection "Single-Phase (L, N, )" followed by the protective earth symbol (read from the rendered page 6-2 of the owner's guide). Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, AC OUTPUT connection row
[1] [2]
Enclosure ratingIndoor only, IP 20
Printed as ingress protection rating "Indoor only, IP 20" for all models; manufacturer claim.
Where: Environmental Specifications, Ingress protection rating row (all models)
[1] [2]
Transfer time< 20 ms
Printed as "Transfer time—utility to invert < 20 ms" for all models.
Where: AC Transfer Specifications, Transfer time row (all models)
[1] [2]
Nominal voltage48 V DC
Printed as "48 VDC" nominal output voltage. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Charger Specifications, Nominal output voltage row
[1] [2]
Surge AC output7,000 W
Printed as "7000 W" 5-second surge. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Output power (AC), 5-second surge row
[1] [2]
Grid passthrough30 A
Printed as "30 A" maximum continuous allowable current in pass-thru, and a 30 A relay current rating for all models. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Maximum continuous allowable (in pass-thru) row; AC Transfer Specifications, Relay current rating
[1] [2]
Idle consumption27 W
Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, No-load power draw (Inverter On) row
[1] [2]
Max parallel units2 units
Printed as "multiple unit configuration (installation) is limited to two units - one master unit and one slave unit".
Where: Introduction, Features (footnote 1)
[1]
Continuous output3.8 kW
Converted: 3800 W / 1000 W per kW = 3.8 kW
Printed as "3800 W" maximum continuous output (footnote: only when NoLoadVD is enabled), 4400 W for 30 minutes and 7000 W 5-second surge, at 25 °C. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Output power (AC), Maximum continuous row
Sources
Converted: 3800 W / 1000 W per kW = 3.8 kW
[1] [2]
Continuous AC output16 A
Printed as "16 A" inverter continuous output current; the inverter peak output current is 42 A. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Inverter continuous output current row
[1] [2]
Battery voltage range40 to 64 V
Printed as "40–64 VDC" DC input voltage range; the maximum continuous power voltage range is 46–48 VDC. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, DC Input, Voltage range row
[1] [2]
Operating temperature-20 to 60 °C / -4 to 140 °F converted
Printed as "–20 to 60 °C", starting to derate above 25 °C.
Where: Environmental Specifications, Operating temperature range row (all models)
[1] [2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3.8 kW
Battery voltage
40 to 64 V
Solar input
Not statedMPPT trackers Not stated
AC output
Single-phase (L, N, earth)
Warranty
Not stated
Size
26.15 L* (Calculated from published dimensions)W: 343 × H: 197 × L: 387 mm / W: 13.5 × H: 7.76 × L: 15.2 inWeight 34.5 kg / 76.1 lb

Evidence score

Research pending10% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Idle consumption27 W0.4 / 10.0

27 against 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band (printed by the maker): Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.

Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.

[1] [2]

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
IEC 62109-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048-61
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0636-01-01 Rev E (CE and RCM marking) for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
IEC 62109-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048-61
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0636-01-01 Rev E (CE and RCM marking) for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 230 V models, document 975-0636-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 27, 2017.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 6.24 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://web.archive.org/web/20170627140245id_/http://solar.schneider-electric.com/wp-content/uploads/2015/09/Conext-SW-Owners-Guide-230VAC-975-0636-01-01_Rev-E_ENG.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
116

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 4df1c195dffe7be7c960c8a2f5175d07a6d5a6e7dd6cf5eaf1594d199f7c1863

Schneider Electric's own Conext SW Inverter/Charger installation guide for the 230 V models, document 975-0637-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 29, 2017.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 15.02 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://web.archive.org/web/20170629171638id_/http://solar.schneider-electric.com/wp-content/uploads/2015/09/Conext-SW-Installation-Guide-230VAC-975-0637-01-01_Rev-E_ENG.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
74

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5c675c94e17bf547c5f3eaed8948edd6497924d7082d948521ccab8c24d0976d

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Conext SW 4048 230

Manufacturer SKU 865-4048-61

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 10
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: IEC 62109-1 · IEC 62109-2
shown detail: Research pending
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 27
unit: Unknown
shown: 27 W
shown detail: Unknown
state: documented
points: 0.4
ceiling: 10
weight: 10
share: 3.7
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1] [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 230 V models, document 975-0636-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 27, 2017. (Schneider Electric · manufacturer · observed Oct 3, 2026)
  2. Schneider Electric's own Conext SW Inverter/Charger installation guide for the 230 V models, document 975-0637-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 29, 2017. (Schneider Electric · manufacturer · observed Oct 3, 2026)

Sign in to report an error on this page

Similar products

All with a price

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

* Missing details