locator: Cover and Copyright and Contact page, Product Part Numbers line
conditions: Part number as printed by Schneider Electric on the covers of the July 2015 owner's guide (975-0636-01-01 Rev E) and installation guide (975-0637-01-01 Rev E) for the 230 V models.
Printed as "34.5 kg" net weight. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Printed as 4400 W for 30 minutes (only when NoLoadVD is enabled) and 7000 W 5-second surge, at 25 °C. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Output power (AC) rows
The model name and other rows say 230 V. Both Rev E guides print the SW 4048 230's nominal output voltage as 240 VAC, while the model is named "Conext SW 4048 230", the SW 2524 230 and SW 4024 230 columns print 230 VAC, and the AC input voltage row prints 230 VAC for all three models. The printed 240 VAC is recorded.
Printed as nominal voltage "240 VAC" in the SW 4048 230 column (read from the rendered page 6-2 of the owner's guide), with an operating voltage range of 219–240 VAC. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Nominal voltage row
Printed as "45 A" maximum charger output current. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Charger Specifications, Maximum output current row
W 343 × H 197 × L 387 mm / W 13.5 × H 7.76 × L 15.2 in converted
Printed as "387×343×197 mm" (L × W × H). Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Peak inverter efficiency, printed as "94%". Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Printed as operating frequency range "selectable 50 or 60 Hz" and default output frequency "50 Hz". Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Operating frequency range and Default output frequency rows
Printed as AC OUTPUT connection "Single-Phase (L, N, )" followed by the protective earth symbol (read from the rendered page 6-2 of the owner's guide). Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, AC OUTPUT connection row
Printed as "48 VDC" nominal output voltage. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Charger Specifications, Nominal output voltage row
Printed as "7000 W" 5-second surge. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Output power (AC), 5-second surge row
Printed as "30 A" maximum continuous allowable current in pass-thru, and a 30 A relay current rating for all models. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Maximum continuous allowable (in pass-thru) row; AC Transfer Specifications, Relay current rating
Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, No-load power draw (Inverter On) row
Printed as "3800 W" maximum continuous output (footnote: only when NoLoadVD is enabled), 4400 W for 30 minutes and 7000 W 5-second surge, at 25 °C. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Output power (AC), Maximum continuous row
Printed as "16 A" inverter continuous output current; the inverter peak output current is 42 A. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, Inverter continuous output current row
Printed as "40–64 VDC" DC input voltage range; the maximum continuous power voltage range is 46–48 VDC. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Where: Inverter Specifications, DC Input, Voltage range row
26.15 L* (Calculated from published dimensions)W: 343 × H: 197 × L: 387 mm / W: 13.5 × H: 7.76 × L: 15.2 inWeight34.5 kg / 76.1 lb
Evidence score
Research pending10% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Idle consumption27 W0.4 / 10.0
27 against 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band (printed by the maker): Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.
Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 230 column (the third column) of the owner's guide 975-0636-01-01 Rev E and the installation guide 975-0637-01-01 Rev E (both July 2015), which name the Conext SW 4048 230 as part number 865-4048-61.
Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
IEC 62109-1manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048-61
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0636-01-01 Rev E (CE and RCM marking) for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
IEC 62109-2manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048-61
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0636-01-01 Rev E (CE and RCM marking) for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
An Internet Archive copy, not a live file. Its cover names the Conext SW 4048 230 (865-4048-61); its Specifications chapter prints the same SW 4048 230 figures as the Rev E owner's guide.
Archived copies
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: Cover, Introduction, Specifications chapter (pages 6-2 to 6-6)
Retrieved Oct 3, 2026
An Internet Archive copy, not a live file: the later revision on solar.se.com answered HTTP 403 to the research agent on October 4, 2026. Its cover names the Conext SW 4048 230 (865-4048-61); its Specifications chapter carries an SW 4048 230 column.
Archived copies
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 230 V models, document 975-0636-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 27, 2017.
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Schneider Electric's own Conext SW Inverter/Charger installation guide for the 230 V models, document 975-0637-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 29, 2017.
Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.