Charged ReviewsSaved 0Compare 0Login
Schneider Electric
Inverter charger

Schneider Electric Conext SW 4048 120/240 Split-phase (865-4048)

Key specs

Weight30.5 kg / 67.2 lb converted Check note
Nominal voltage48 V DC
Efficiency98 % Check note
Continuous output3.8 kW
Converted: 3800 W / 1000 W per kW = 3.8 kW
Max charge45 A
AC frequency50 or 60 Hz (selectable); 60 Hz default

All specifications

Identity

BrandSchneider Electric · Website
ModelConext SW 4048 120/240
MarketUnknown
Manufacturer SKU865-4048
SKU detail
locator: Cover and Copyright and Contact page, Product Part Numbers line
conditions: Part number as printed by Schneider Electric on the covers of the July 2015 owner's guide (Rev E) and installation guide (Rev D) and in the 2016 datasheet's Part number row.
Sources: [1] [2] [3]
FieldValueConditionsSource
Weight30.5 kg / 67.2 lb converted Check note
The datasheet prints a lower weight. Schneider Electric's datasheet (DS20160624_ConextSW) prints "Product weight" as "28.1 kg (62.0 lb)" for the SW 4048 120/240. The Rev E owner's guide and installation guide print 67.2 lbs. (30.5 kg), which is recorded.
Printed as "67.2 lbs. (30.5 kg)" unit net weight. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Physical Specifications, Unit Net Weight row
[1] [2]
Peak output4400 W for 30 min; 7000 W for 5 s
Printed as 4400 W for 30 minutes (only when NoLoadVD is enabled) and 7000 W for 5 seconds, at 25 °C. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Inverter Specifications, Continuous output power (AC) and Surge power rating rows
[1] [2]
AC voltage120/240 VAC
Printed as nominal voltage "120/240 VAC" single-phase/split-phase; the operating voltage range is 104/208 VAC to 127/254 VAC. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Inverter Specifications, Nominal voltage single-phase/split-phase row
[1] [2]
Max charge45 A
Printed as "45 A" maximum charger output current. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Charger Specifications, Maximum output current row; datasheet charger Output current row
[1] [2] [3]
DimensionsW 343 × H 197 × L 387 mm / W 13.5 × H 7.76 × L 15.2 in converted Check note
The datasheet prints different dimensions. Schneider Electric's datasheet (DS20160624_ConextSW) prints "Product dimensions (H x W x D)" as "41.8 x 34.1 x 19.7 cm (16.5 x 13.4 x 7.6 in)". The Rev E owner's guide and installation guide print 387×343×197 mm (L × W × H), which is recorded.
Printed as "15.2×13.5×7.6 in (387×343×197 mm)" (L × W × H); the millimeter figures are recorded. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Physical Specifications, L × W × H row
[1] [2]
Efficiency98 % Check note
Other Schneider documents print 94%. The Rev E owner's guide (975-0638-01-01) and the Rev D installation guide (975-0639-01-01) both print "Peak efficiency 91.5% 92% 98%", so 98% is recorded for the SW 4048 120/240 (865-4048). Schneider Electric's datasheet of 2016 (DS20160624_ConextSW) prints "Optimal efficiency" as 94% for the SW 4048 120/240, and the 2020 revisions of the same guides, written for 865-4048-21, print 94%.
Peak inverter efficiency, printed as "98%". Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Inverter Specifications, Peak efficiency row
[1] [2]
AC frequency50 or 60 Hz (selectable); 60 Hz default
Printed as operating frequency range "selectable 50 or 60 Hz" and default output frequency "60 Hz". Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Inverter Specifications, Operating frequency range and Default output frequency rows
[1] [2]
AC configuration120/240 V split phase (L1/L2 with neutral)
Printed as "AC OUTPUT connection Split-phase (L1/L2) Split-phase (L1/L2) Split-phase (L1/L2)"; "Nominal voltage single-phase/split-phase 120/240 VAC 120/240 VAC 120/240 VAC"; "The terminals are labeled OUTPUT N for Neutral and OUTPUT L1 and L2 for split-phase lines 1 and 2 respectively." in Schneider Electric's own Conext SW Inverter/Charger installation guide for the 120/240 V models, document 975-0639-01-01 Rev D (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 19, 2017. (PDF page 62; PDF page 23). Revised on 16 October 2026: Owner report 2026-10-16 (inverter filter AC output 120/240 V): the earlier text omitted the voltages the manual prints, so the unit fell out of the 120/240 V filter although one unit gives 120 V line to neutral and 240 V line to line.
Where: PDF page 62; PDF page 23
[2]
Enclosure ratingIndoor only, IP 20
Printed as ingress protection rating "Indoor only, IP 20" for all models; manufacturer claim.
Where: Environmental Specifications, Ingress protection rating row (all models)
[1] [2]
Transfer time< 20 ms
Printed as "Transfer time—utility to invert < 20 ms" for all models.
Where: AC Transfer Specifications, Transfer time row (all models)
[1] [2]
Nominal voltage48 V DC
Printed as "48 VDC" nominal output voltage. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Charger Specifications, Nominal output voltage row
[1] [2]
Surge AC output7,000 W
Printed as "7000 W" surge power rating for 5 seconds. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Inverter Specifications, Surge power rating (5 seconds) row
[1] [2] [3]
Grid passthrough30 A
Printed as relay current rating "30 A" for all models, with the footnote "Limited by SCP to 24 A due to CEC/NEC regulatory requirements."
Where: AC Transfer Specifications, Relay current rating row (all models)
[1] [2]
Idle consumption27 W
Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Specifications, No-load power draw (Inverter On) row
[1] [2]
Max parallel units2 units
Printed as "multiple unit configuration (installation) is limited to two units - one master unit and one slave unit". The 2016 datasheet lists the Conext SW Stacking Kit 865-1019 for 120 / 240 Vac. The 2020 owner's guide for 865-4048-21 instead says operation of more than one Conext SW in a stack is not supported.
Where: Introduction, Features (footnote 1) and Multiple Unit Configuration
[1]
Continuous output3.8 kW
Converted: 3800 W / 1000 W per kW = 3.8 kW
Printed as "3800 W" maximum continuous output (footnote: only when NoLoadVD is enabled) and 4400 W for 30 minutes, at 25 °C. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Specifications chapter, Inverter Specifications, Continuous output power (AC), SW 4048 120/240 column
Sources
Converted: 3800 W / 1000 W per kW = 3.8 kW
[1] [2] [3]
Continuous AC output15.2 A
Printed as "15.2 A" maximum continuous output current; the inverter peak output current is 41 A. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Inverter Specifications, Maximum continuous output current row
[1] [2]
Battery voltage range40 to 64 V Check note
The datasheet prints a wider range. Schneider Electric's datasheet (DS20160624_ConextSW) prints "Input DC voltage range" as "40 - 68 Vdc" for the SW 4048 120/240. The Rev E owner's guide and installation guide print 40–64 VDC, which is recorded.
Printed as "40–64 VDC" DC input voltage range; the maximum continuous power voltage range is 46–48 VDC. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.
Where: Inverter Specifications, DC Input, Voltage range row
[1] [2]
Operating temperature-20 to 60 °C / -4 to 140 °F converted
Printed as "–4 to 140 °F (–20 to 60 °C)", starting to derate above 77 °F (25 °C).
Where: Environmental Specifications, Operating temperature range row (all models)
[1] [2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3.8 kW
Battery voltage
40 to 64 V
Solar input
Not statedMPPT trackers Not stated
AC output
120/240 V split phase (L1/L2 with neutral)
Warranty
Not stated
Size
26.15 L* (Calculated from published dimensions)W: 343 × H: 197 × L: 387 mm / W: 13.5 × H: 7.76 × L: 15.2 inWeight 30.5 kg / 67.2 lb

Evidence score

11/100Missing details55% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Warranty term needed; Battery conversion efficiency needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

CertificatesUL 1741 · UL 1778 +1Claimed10.2 / 45.0

Manufacturer claim; issuer verification pending. Applies to the exact inverter.

[1]

Idle consumption27 W0.4 / 10.0

27 against 1 W, the lowest documented for an inverter in the 3.5 to 7 kW output band (printed by the maker): Fronius Primo 3.8-1 208-240. The bar is a printed bound: less than 1 W, as printed.

Printed as "27 W" no-load power draw with the inverter on. Read from the SW 4048 120/240 column (the third column) of the owner's guide 975-0638-01-01 Rev E and the installation guide 975-0639-01-01 Rev D (both July 2015), which name the Conext SW 4048 120/240 as part number 865-4048.

[1] [2]

Research pending, 0 points: Warranty term, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.
CSA C22.2 No. 107.1-01manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0638-01-01 Rev E for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1741manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0638-01-01 Rev E for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]
UL 1778manufacturer claimpresent at observation[1]
Scope
equipment listing
Covered models
865-4048
Limitations
Printed in the Regulatory section of Schneider Electric's own owner's guide 975-0638-01-01 Rev E for all models it covers; no certificate number or issuer file number is given, so this is a manufacturer claim and not issuer-verified. Read on October 4, 2026.
Record detail
Issued: Not stated
Valid from: Not stated
Expiry: Not stated
Not checked
Source
[1]

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 120/240 V models, document 975-0638-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 19, 2017.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 6.17 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://web.archive.org/web/20170619203809id_/http://solar.schneider-electric.com/wp-content/uploads/2015/09/Conext-SW-NA-Owners-Guide-120-240VAC-975-0638-01-01_Rev-E_ENG.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
116

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6f8a46c57164bd42b7e6d428684b8546b882f927f87c3c1d72deeced3a572336

Schneider Electric's own Conext SW Inverter/Charger installation guide for the 120/240 V models, document 975-0639-01-01 Rev D (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 19, 2017.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 12.76 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://web.archive.org/web/20170619141606id_/http://solar.schneider-electric.com/wp-content/uploads/2015/09/Conext-SW-NA-Installation-Guide-120-240VAC-975-0639-01-01_Rev-D_ENG.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
None
Embedded modification date
None
Pages
76

Embedded dates are file metadata, not independent proof of publication.

SHA-256: bf0331821455323f084b0d3a970bce878fded43a9133112484f7dcba5708df56

Schneider Electric's own Conext SW inverter/charger datasheet, Technical Specifications - North America (DS20160624_ConextSW), Internet Archive copy of solar.schneider-electric.com captured June 19, 2017.

Archived copy of a document published by Schneider Electric. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupRevision not recorded · 0.91 MB

Archived copy, unaltered, kept as a record of what Schneider Electric published. Original address: https://web.archive.org/web/20170619151704id_/http://solar.schneider-electric.com/wp-content/uploads/2016/06/Conext-SW_-Data-Sheet-NA.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d0ea72912f5ac15495e53d5e03383a12b051db47c46c33b24547d7ec725a4c2c

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
Conext SW 4048 120/240

Manufacturer SKU 865-4048

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 55
basis: Unknown
missing:
Warranty term needed
Battery conversion efficiency needed
criteria:
key: certificates
label: Certificates
value: 22.75
unit: Unknown
shown: UL 1741 · UL 1778 +1
shown detail: Claimed
state: claimed
points: 10.2
ceiling: 45
weight: 45
share: 22.8
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note: Manufacturer claim; issuer verification pending. Applies to the exact inverter.
display note: Unknown
Sources: [1]
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 27
unit: Unknown
shown: 27 W
shown detail: Unknown
state: documented
points: 0.4
ceiling: 10
weight: 10
share: 3.7
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1] [2]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Schneider Electric's own Conext SW Inverter/Charger owner's guide for the 120/240 V models, document 975-0638-01-01 Rev E (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 19, 2017. (Schneider Electric · manufacturer · observed Oct 3, 2026)
  2. Schneider Electric's own Conext SW Inverter/Charger installation guide for the 120/240 V models, document 975-0639-01-01 Rev D (July 2015), Internet Archive copy of solar.schneider-electric.com captured June 19, 2017. (Schneider Electric · manufacturer · observed Oct 3, 2026)
  3. Schneider Electric's own Conext SW inverter/charger datasheet, Technical Specifications - North America (DS20160624_ConextSW), Internet Archive copy of solar.schneider-electric.com captured June 19, 2017. (Schneider Electric · manufacturer · observed Oct 3, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details