Charged Reviews is paused for an update. You can browse and search, but sign-in, reviews, comments, votes and deals are off for now.

Riello Solartech Sirio K800 HHV-MT Central Inverter

By Riello SolartechSKU not documented

Key specs

Units
Weight
1,380 kg3,042 lb converted
Official instruction manual
Sources

The installation manual prints "1380" kg in the row "Weight" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Mechanical, Weight), the same value as the datasheet. Datasheet: Printed as "1380 + 200 (DC BOX)" in the row "Weight [kg]", SIRIO K800 HHV-MT column; the inverter cabinet, the DC box adds 200 kg as printed.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Mechanical, Weight; datasheet, Page 8, Mechanical, Weight [kg], SIRIO K800 HHV-MT column

Documented

Dimensions
2,850 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 1,500 × H: 1,900 × D: 1,000 mmW: 59.06 × H: 74.8 × D: 39.37 in convertedOfficial instruction manual
Sources

The installation manual prints the same dimensions in the row "Dimensions mm" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Mechanical, Dimensions), the same value as the datasheet. Datasheet: Printed as "1500x1000x1900" in the row "Dimensions (WxDxH) [mm]" for this model (the inverter cabinet; the cell adds "+ 600x1000x1900 DC BOX"); recorded as width, depth and height in millimeters.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Mechanical, Dimensions; datasheet, Page 8, Mechanical, Dimensions (WxDxH) [mm]

Calculated

Communications
Ethernet; USB; 2 x RS232; RS485 (optional); ModBUS RTU (optional); ModBUS/TCP
Official datasheet
Sources

Printed as "Ethernet, USB, 2xRS232, 2 inputs for remote controls (inverter trip and EPO) and 3 operating status signal relays. Optional RS485 and ModBUS RTU (slot version)" under "COMMUNICATION INTERFACE" and "ModBUS / TCP" under "PROTOCOL", for every Sirio Central model.

Official datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Page 6, Communications

Documented

MPPT voltage range
530 to 820 V
Official instruction manual
Sources

The installation manual prints "530-820 V" in the row "DC voltage range, MPPT" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", DC voltage range, MPPT Vcc), the same value as the datasheet. Datasheet: Printed as "530 - 820" in the row "DC voltage range, MPPT (Vdc) [V]" for this model.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", DC voltage range, MPPT Vcc; datasheet, Page 8, Input, DC voltage range, MPPT (Vdc) [V]

Documented

PV array limit
880 kW
Official instruction manual
Sources

The installation manual prints "880" kWp in the row "Max PV power Pmax" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Max PV power Pmax), the same value as the datasheet. Datasheet: Printed as "880" in the row "PV max power (Pmax) [kWp]", SIRIO K800 HHV-MT column; the largest PV array the model takes, in kWp.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Max PV power Pmax; datasheet, Page 8, Input, PV max power (Pmax) [kWp], SIRIO K800 HHV-MT column

Documented

AC frequency
50 Hz (+2 / -3)
Official instruction manual
Sources

The installation manual prints the same rated frequency in the row "Rated frequency Fca" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated frequency Fca), the same value as the datasheet. Datasheet: Printed as "50 (+2 / -3)" in the row "Nominal frequency (Fca) [Hz]", one value for every model.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated frequency Fca; datasheet, Page 8, Output, Nominal frequency (Fca) [Hz]

Documented

AC output
Three-phase, 320 V, IT distribution system
Official instruction manual
Sources

The installation manual prints the same rated voltage in the row "Rated voltage Vca" and the same distribution system (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated voltage Vca and Distribution system), the same value as the datasheet. Datasheet: Printed as "320 three-phase (+/- 15%)" in the row "Nominal voltage (Vac) [V]" and "IT" in the row "Distribution system" for this model.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated voltage Vca and Distribution system; datasheet, Page 8, Output, Nominal voltage (Vac) [V] and Distribution system

Documented

Enclosure
IP20
Official instruction manual
Sources

The installation manual prints "IP20" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Ingress protection EN60529), the same value as the datasheet. Datasheet: Printed as "IP20" in the row "Protection level EN60529"; the row "Environmental category" prints "Indoors, not air conditioned".

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Ingress protection EN60529; datasheet, Page 8, Environmental protections and conditions, Protection level EN60529

Documented

All specs14
AC frequency
50 Hz (+2 / -3)
Official instruction manual
Sources

The installation manual prints the same rated frequency in the row "Rated frequency Fca" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated frequency Fca), the same value as the datasheet. Datasheet: Printed as "50 (+2 / -3)" in the row "Nominal frequency (Fca) [Hz]", one value for every model.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated frequency Fca; datasheet, Page 8, Output, Nominal frequency (Fca) [Hz]

Documented

AC output
Three-phase, 320 V, IT distribution system
Official instruction manual
Sources

The installation manual prints the same rated voltage in the row "Rated voltage Vca" and the same distribution system (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated voltage Vca and Distribution system), the same value as the datasheet. Datasheet: Printed as "320 three-phase (+/- 15%)" in the row "Nominal voltage (Vac) [V]" and "IT" in the row "Distribution system" for this model.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated voltage Vca and Distribution system; datasheet, Page 8, Output, Nominal voltage (Vac) [V] and Distribution system

Documented

Continuous output
800 kW
Official instruction manual
Sources

The installation manual prints "800" kW in the row "Rated AC power" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated AC power Pca), the same value as the datasheet. Datasheet: Printed as "800" in the row "Nominal AC power (p.f. =1) (Pca) [kW]", SIRIO K800 HHV-MT column.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated AC power Pca; datasheet, Page 8, Output, Nominal AC power (p.f. =1) (Pca) [kW], SIRIO K800 HHV-MT column

Documented

Continuous AC current
1,450 A
Official instruction manual
Sources

The installation manual prints "1450" A in the row "Rated current Ica" (General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated current Ica), the same value as the datasheet. Datasheet: Printed as "1450" in the row "Rated current (Ica) [Aca]", SIRIO K800 HHV-MT column.

Official instruction manual: Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00 Rev 0MNPV364K55ENUG Rev.00 · Checked · Earlier documentOfficial datasheet: Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN Rev DATSIHX0Y26GSEN · Checked · Earlier document

Location: Installation manual, General characteristics, page 25, K800 HHV-MT column under "SIRIO HHV MT Model K800", Rated current Ica; datasheet, Page 8, Output, Rated current (Ica) [Aca], SIRIO K800 HHV-MT column

Documented

Published claims and calculations, not independent test results.

Documents

3 on file
  • PDF
    Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSENOfficialRiello SolartechOfficial datasheet
    Source details
    Revision
    DATSIHX0Y26GSEN
    Revision date
    Not stated

    Archived copy captured on 2026-10-22.

    Location: Pages 3, 4, 7 and 8, model tables; pages 1 and 5, product photos

    Retrieved

    Riello Solartech's own English datasheet (PDF, published by RPS S.p.A., Riello Solartech Division), linked from the product's download area on www.riello-solartech.com and captured on October 22, 2026. The tables merge cells that apply to several models; every value was paired with its model columns on the rendered page. The datasheet says the product photos are merely an indication and that features may change without notice. Manufacturer document, not an independent test.

    Archived copies

    Archived copy of a document published by Riello Solartech. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup DATSIHX0Y26GSEN · 0.68 MB

    Archived copy, unaltered, kept as a record of what Riello Solartech published. Original address: https://www.riello-solartech.com/storage/2026/10/datsihx0y26gsen.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    8
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 7130c609d9c55d55bb327b8f9784791c216431c73178ecbb5a47e7321079d16c

    Open
  • PDF
    Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00OfficialRiello SolartechOfficial instruction manual
    Source details
    Revision
    0MNPV364K55ENUG Rev.00
    Revision date
    Not stated

    Archived copy captured on 2026-10-22.

    Location: General characteristics tables, manual pages 22 to 25

    Retrieved

    Riello Solartech's own English user and installation manual (PDF), linked from the download area of www.riello-solartech.com and captured on October 22, 2026. It covers the Sirio HV MT K64 to K500 and Sirio HHV MT K330, K500 and K800 central inverters; its technical specifications appendix is the primary source for the values it prints for those exact models. Manufacturer document, not an independent test.

    Archived copies

    Archived copy of a document published by Riello Solartech. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup 0MNPV364K55ENUG Rev.00 · 1.55 MB

    Archived copy, unaltered, kept as a record of what Riello Solartech published. Original address: https://www.riello-solartech.com/storage/2024/11/0MNPV364K55ENUG-00-Manu-PV3-PV4-64-800KW-ENaral111120pasi.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    30
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 0cccaf745e13ef0a9dea0746d32ba3a7604e97f12831e2f63af22689a65031cd

    Open
  • WEB
    Riello Solartech product page: Sirio Three-Phase (October 22, 2026 capture)OfficialRiello SolartechOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-22.

    Location: Page heading and main features

    Retrieved

    Riello Solartech's own product page (www.riello-solartech.com, English edition), captured on October 22, 2026 with the paced research fetcher; the content is whatever the address served on that date. Manufacturer statements, not independent tests; the page carries no revision date.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Riello Solartech user manual: Sirio HV MT and HHV MT central inverters, 64 to 800 kW, 0MNPV364K55ENUG Rev.00

Archived copy of a document published by Riello Solartech. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup 0MNPV364K55ENUG Rev.00 · 1.55 MB

Archived copy, unaltered, kept as a record of what Riello Solartech published. Original address: https://www.riello-solartech.com/storage/2024/11/0MNPV364K55ENUG-00-Manu-PV3-PV4-64-800KW-ENaral111120pasi.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
30
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 0cccaf745e13ef0a9dea0746d32ba3a7604e97f12831e2f63af22689a65031cd

Riello Solartech datasheet: Sirio Central Inverters and Sirio Central Inverters MV, DATSIHX0Y26GSEN

Archived copy of a document published by Riello Solartech. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup DATSIHX0Y26GSEN · 0.68 MB

Archived copy, unaltered, kept as a record of what Riello Solartech published. Original address: https://www.riello-solartech.com/storage/2026/10/datsihx0y26gsen.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
8
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 7130c609d9c55d55bb327b8f9784791c216431c73178ecbb5a47e7321079d16c

Submit a document

Warranty

No warranty terms on file.

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same over 50 kW output band. · Method version 0.5

How it works

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
SIRIO K800 HHV-MT

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.