About brandPowMr sells off-grid and hybrid solar inverters, MPPT and PWM solar charge controllers, LiFePO4 batteries and solar panels under its own name through its store at powmr.com.
SKU detail
conditions: PowMr's documents print no separate SKU or part number, and the model has no listing on PowMr's store (storefront listing read on October 13, 2026); the model is recorded as the documents print it.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Weight
19 kg / 42 lb converted
The manual prints "Net weight 19kg 27.4kg 50.7kg" in separate model columns; 19kg is the POW-RELAB 3KU-SPLIT column. The catalog prints 19kg too.
Where: PDF page 43 (printed page 40), 8.4 Table 4: General Parameters, Net weight
The manual prints "Dimensions (LxWxH) 465*310*135mm 545*400*200mm"; the 465*310*135mm cell is the 3KU-SPLIT column alone. The catalog prints 465x310x135mm in its own 3KU-SPLIT column.
Where: PDF page 43 (printed page 40), 8.4 Table 4: General Parameters, Dimensions (LxWxH)
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) prints a 2700W PV array, a 30~245Vdc MPPT range, a 245Vdc maximum open-circuit voltage and a 100A maximum PV charging current for the POW-RELAB 3KU-SPLIT; PowMr's 2026 catalog prints 1600W, 30~105Vdc, 105Vdc and 60A for this model.
The manual prints "MPPT Input Voltage Range 30~245Vdc 60~245Vdc"; the 30~245Vdc cell is the POW-RELAB 3KU-SPLIT column alone. The catalog prints a different range, kept as an alternative.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, MPPT Input Voltage Range
Sources
30 to 105 V
The 2026 catalog prints "PV Array MPPT Range" 30~105Vdc in its own 3KU-SPLIT column.
2.7 kW*Converted: 2700 W / 1000 W per kW = 2.7 kWCheck note
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) prints a 2700W PV array, a 30~245Vdc MPPT range, a 245Vdc maximum open-circuit voltage and a 100A maximum PV charging current for the POW-RELAB 3KU-SPLIT; PowMr's 2026 catalog prints 1600W, 30~105Vdc, 105Vdc and 60A for this model.
The manual prints "Max. PV Array Power 2700W 5400W"; the 2700W cell is the POW-RELAB 3KU-SPLIT column alone. The catalog prints a different figure, kept as an alternative. Manufacturer claim, not an independent test.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Max. PV Array Power
Sources
Converted: 2700 W / 1000 W per kW = 2.7 kW
1.6 kW
The 2026 catalog prints "Max. PV Array Power" 1600W in its own 3KU-SPLIT column (1600 W / 1000 = 1.6 kW).
The manual prints "Max. AC Charging Current 38A 50A 105A" in separate model columns; 38A is the POW-RELAB 3KU-SPLIT column. The catalog prints 38A in its 3KU-SPLIT column.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Max. AC Charging Current
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) prints a 2700W PV array, a 30~245Vdc MPPT range, a 245Vdc maximum open-circuit voltage and a 100A maximum PV charging current for the POW-RELAB 3KU-SPLIT; PowMr's 2026 catalog prints 1600W, 30~105Vdc, 105Vdc and 60A for this model.
The manual prints "Max. PV Charging Current 100A" in a cell spanning all three model columns. The 2026 catalog prints a different figure, kept as an alternative.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Max. PV Charging Current
Sources
60 A
The 2026 catalog prints "Max. PV Charging Current" 60A in its own 3KU-SPLIT column.
110 V N-L1 / N-L2 and 220 V L1-L2 split phase, 50/60 Hz
The manual prints "Nominal Output Voltage 110Vac(N-L1/N-L2)/ 220Vac(L1-L2)" and "Output Frequency 50Hz / 60Hz" in cells spanning all three model columns.
Where: PDF page 41 (printed page 38), 8.2 Table 2: Inverter Mode Parameters, Nominal Output Voltage and Output Frequency
PowMr documents disagree. The POW-RELAB-SPLIT series user manual (V2.1) prints a 2700W PV array, a 30~245Vdc MPPT range, a 245Vdc maximum open-circuit voltage and a 100A maximum PV charging current for the POW-RELAB 3KU-SPLIT; PowMr's 2026 catalog prints 1600W, 30~105Vdc, 105Vdc and 60A for this model.
The manual prints "Max. PV Array Open Circuit Voltage 245Vdc 245Vdc"; the first 245Vdc cell is the POW-RELAB 3KU-SPLIT column. The catalog prints a different figure, kept as an alternative.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Max. PV Array Open Circuit Voltage
Sources
105 V
The 2026 catalog prints "Max. PV Array Open Circuit Voltage" 105Vdc in a cell spanning all three RELAB-SPLIT columns.
The manual prints "Nominal DC Input Voltage 24Vdc 48Vdc"; the 24Vdc cell is the POW-RELAB 3KU-SPLIT column alone (the 48Vdc cell spans the 5KU-SPLIT and 10KU-SPLIT columns). The catalog prints "System Voltage" 24V in its own 3KU-SPLIT column.
Where: PDF page 41 (printed page 38), 8.2 Table 2: Inverter Mode Parameters, Nominal DC Input Voltage
The manual prints "Peak Power 9000W 15000W 30000W" in separate model columns; 9000W is the POW-RELAB 3KU-SPLIT column. No duration is printed there; the catalog prints "Surge Capacity 2*rated power for 5 seconds" across the series.
Where: PDF page 41 (printed page 38), 8.2 Table 2: Inverter Mode Parameters, Peak Power
The manual prints "Rated Output Power 3000W 5000W 10000W" in separate model columns; 3000W is the POW-RELAB 3KU-SPLIT column. The catalog prints 3000W in its own POW-RELAB 3KU-SPLIT column. Manufacturer claim, not an independent test.
Where: PDF page 41 (printed page 38), 8.2 Table 2: Inverter Mode Parameters, Rated Output Power
The manual prints "Battery Charging Voltage 27.4VDC 54.8VDC"; the 27.4VDC cell is the 3KU-SPLIT column and the 54.8VDC cell spans the 5KU-SPLIT and 10KU-SPLIT columns.
Where: PDF page 42 (printed page 39), 8.3 Table 3: Charging Mode Parameters, Battery Charging Voltage
2.7 kWMPPT trackersNot statedMPPT range30 to 245 V
AC output
110 V N-L1 / N-L2 and 220 V L1-L2 split phase, 50/60 Hz
Warranty
Not stated
Size
Unknown465x310x135mmWeight19 kg / 42 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
Location: 8 Specifications, Tables 1 to 4, PDF pages 41 to 43 (rendered and read)
Retrieved Oct 12, 2026
The English user manual for the POW-RELAB 3KU-SPLIT, 5KU-SPLIT and 10KU-SPLIT that PowMr's site menu links, served from its Shopify file store and captured on October 13, 2026. Its specification tables (PDF pages 41 to 43, printed pages 38 to 40) have one column per model; several cells span two or three columns and were read from the rendered pages. The file name gives version V2.1.0403; no date is printed. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Location: PDF pages 116 and 120 (rendered and read)
Retrieved Oct 9, 2026
PowMr's 2026 product catalog, linked as "PowMr Brochure 2026" from every page of PowMr's store and served from its Shopify file store, captured on October 9, 2026. Its specification tables for the POW-M60-ULTRA (PDF page 116) and the POW-M80-PRO and POW-M100-PRO (PDF page 120) are laid out so that the extracted text separates labels from values; those pages were rendered and read directly, and figures cite the rendered PDF page. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
PowMr POW-RELAB-SPLIT series user manual V2.1 (PDF, English)
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].