92 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
The manual prints "Max. Efficiency of Battery Inverter 93% 92%" in separate model columns; 92% is the POW-ESS12.5KW-SP column, a maximum figure.
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 41.2 kg / 90.8 lb converted | The manual prints "Weight 38 kg 41.2 kg" in separate model columns; 41.2 kg is the POW-ESS12.5KW-SP column. Where: PDF page 92 (printed page 89), 14 Technical Data, Universal, Weight | [1] |
| MPPT count | 2 | The manual prints "MPPT Way Number 1 2" in separate model columns; 2 is the POW-ESS12.5KW-SP column. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, PV Input, MPPT Way Number | [1] |
| Max charge | 200 A | The manual prints "Max. Hybrid Charging Current 120A 200A" in separate model columns; 200A is the POW-ESS12.5KW-SP column. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Battery, Max. Hybrid Charging Current | [1] |
| Dimensions | 584*196*804 mm | The manual prints "Size 584*196*804 mm 584*196*804 mm", the same size in each model column; the axes are not named. Where: PDF page 92 (printed page 89), 14 Technical Data, Universal, Size | [1] |
| Communications | RS485; CAN; Dry contact; Wi-Fi; Bluetooth | The manual prints "Built-in Interface RS485/ CAN / Dry contact" and "Communication Module WIFI/Bluetooth" in cells spanning both model columns. Where: PDF page 92 (printed page 89), 14 Technical Data, Communication | [1] |
| MPPT voltage | 125 to 425 V | The manual prints "MPPT Operating Voltage Range 125~425Vdc 125~425Vdc", the same range in each model column. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, PV Input, MPPT Operating Voltage Range | [1] |
| Max AC charge | 100 A | The manual prints "Max. Mains/ Generator Charging Current 100A 100A", 100A in each model column. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Battery, Max. Mains/ Generator Charging Current | [1] |
| Max PV charge | 200 A | The manual prints "Max. PV Charging Current 120A 200A" in separate model columns; 200A is the POW-ESS12.5KW-SP column. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Battery, Max. PV Charging Current | [1] |
| Output waveform | Pure sine wave | The manual prints "Output Waveform Pure sine wave" in a cell spanning both model columns. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Output Waveform | [1] |
| AC configuration | 120/240 V split phase (100/110/120/127 V; 200/220/240 V; 208 V; 220 V settable), 50/60 Hz | The manual prints "Rated Output Voltage 100/110/120/127V; 200/220/240V; 208V; 220V" and "Rated Frequency 50/60Hz" in cells spanning both model columns; its connection overview (PDF page 29) gives 120 V L-N and 240 V L-L as the split-phase defaults. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Rated Output Voltage and Rated Frequency | [1] |
| Enclosure rating | IP20 | The manual prints "Level of Protection IP20, for indoor use only" in a cell spanning both model columns. Where: PDF page 92 (printed page 89), 14 Technical Data, Universal, Level of Protection | [1] |
| Max PV current | 22 / 22 A | The manual prints "Max. Input Current 27A 22A+22A" in separate model columns; "22A+22A", one figure for each tracker, is the POW-ESS12.5KW-SP column, which prints "Max. Input Power 9,000 W + 9,000 W". Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, PV Input, Max. Input Current | [1] |
| Max PV voltage | 500 V | The manual prints "Max. Open Circuit Voltage 500Vdc 500Vdc+500Vdc"; "500Vdc+500Vdc", the same figure for each tracker, is the POW-ESS12.5KW-SP column. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, PV Input, Max. Open Circuit Voltage | [1] |
| Transfer time | 10 ms typical; 20 ms maximum for a single unit, 30 ms in parallel | The manual prints "Switching Time 10 ms (typ.), 20 ms (max. single), 30 ms (max. parallel)" in a cell spanning both model columns. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Switching Time | [1] |
| Nominal voltage | 48 V | The manual prints "Rated Battery Voltage 48Vdc" in a cell spanning both model columns. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Battery, Rated Battery Voltage | [1] |
| Surge AC output | 25,000 W | The manual prints "Max. Peak Power 16,000W 25,000W" in separate model columns; 25,000W is the POW-ESS12.5KW-SP column. No duration is printed. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Max. Peak Power | [1] |
| Grid passthrough | 63 A | The manual prints "Bypass Overload Current 45A 63A" in separate model columns; 63A is the POW-ESS12.5KW-SP column. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Mains/Generator Input, Bypass Overload Current | [1] |
| Continuous output | 12.5 kWConverted: 12500 W / 1000 W per kW = 12.5 kW | The manual prints "Rated Output Power 8,000W 12,500W" in separate model columns; 12,500W is the POW-ESS12.5KW-SP column. The product page prints "Rated Load Power (W) 12,500W". Manufacturer claim, not an independent test. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Inverter Output, Rated Output Power SourcesConverted: 12500 W / 1000 W per kW = 12.5 kW | [1] [2] |
| Battery compatibility | Lithium-ion or lead-acid batteries | The manual prints "Battery Type Lithium-ion battery/lead-acid battery" in a cell spanning both model columns. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Battery, Battery Type | [1] |
| Battery efficiency | 92 % maximum battery inverter efficiency | The manual prints "Max. Efficiency of Battery Inverter 93% 92%" in separate model columns; 92% is the POW-ESS12.5KW-SP column, a maximum figure. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Efficiency, Max. Efficiency of Battery Inverter | [1] |
| Battery voltage range | 40 to 60 V | The manual prints "Voltage Range 40~60Vdc" in a cell spanning both model columns. Where: PDF page 91 (printed page 88), 14 Technical Data, ESS Inverter Module, Battery, Voltage Range | [1] |
| Operating temperature | -10 to 55 °C / 14 to 131 °F converted derated above 45 °C | The manual prints "Ambient Temperature -10 to 55℃, >45℃ derated" in a cell spanning both model columns. Where: PDF page 92 (printed page 89), 14 Technical Data, Universal, Ambient Temperature | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
92 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
The manual prints "Max. Efficiency of Battery Inverter 93% 92%" in separate model columns; 92% is the POW-ESS12.5KW-SP column, a maximum figure.
Research pending, 0 points: Certificates, Warranty term, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
Unknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-13.
Location: 14 Technical Data, PDF pages 91 and 92 (rendered and read)
Retrieved Oct 13, 2026
The English user manual for the PowMr POW-ESS series all-in-one energy storage system that PowMr's product page links, served from its Shopify file store and captured on October 13, 2026. Its scope (PDF page 4) names two inverter modules, the POW-ESS8KW-SP and POW-ESS12.5KW-SP, and one battery module, the POW-ESS-16KWH. Its technical data (PDF pages 91 and 92, printed pages 88 and 89) has an inverter module table with one column per inverter model, read from the rendered pages because several cells span both columns, and a single-model battery module table. No version or date is printed. Manufacturer claims, not independent tests.
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what PowMr published. Original address: https://cdn.shopify.com/s/files/1/0746/0415/1079/files/POW-ESS8KW-12.5KW-SP_POW-ESS-16KWH_ALL-IN-ONE_ESS_User_Manual.pdf?v=1784169929. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: b41b92ef86b6172ec3716cab7c5124b60032d374888b7772be98c92312772e27
Archived copy captured on 2026-10-13.
Location: SKU line; Overview; Specifications
Retrieved Oct 13, 2026
PowMr's own store page at powmr.com, captured on October 13, 2026; the content is whatever the address served on that date. Only the page's own description, its SKU line and its single-model Specifications block are read; the page's product comparison table is not used. The page prints no market or region and carries no revision date. Manufacturer claims, not independent tests. The listing sells the POW-ESS12.5KW-SP inverter module together with a battery module as one system.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by PowMr. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what PowMr published. Original address: https://cdn.shopify.com/s/files/1/0746/0415/1079/files/POW-ESS8KW-12.5KW-SP_POW-ESS-16KWH_ALL-IN-ONE_ESS_User_Manual.pdf?v=1784169929. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: b41b92ef86b6172ec3716cab7c5124b60032d374888b7772be98c92312772e27
No sourced accessories or replacement parts listed yet.
Manufacturer SKU unknown
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 15 basis: Unknown missing: Certificate evidence needed Warranty term needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: 92 unit: Unknown shown: 92 % shown detail: Unknown state: documented points: 14.1 ceiling: 15 weight: 15 share: 93.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.