Charged ReviewsSaved 0Compare 0Login

Phocos Any-Grid PSW-H-3KW-120/24V Hybrid Inverter Charger

Key specs

BrandPhocos
ModelPSW-H-3KW-120/24V
MarketUS
Continuous output3 kW
Converted: 3000 W / 1000 W per kW = 3 kW
Apparent power3,000 VA
Peak output2x nominal power for 5 seconds
AC voltage120 Vac ± 5% (programmable, 110 ~ 127 Vac)
PV conversion limit4 kW
Converted: 4000 W / 1000 W per kW = 4 kW
Connected-array allowance5 kW
Converted: 5000 Wp / 1000 W per kW = 5 kW
MPPT voltage range90 to 230 V
Efficiency> 90
Weight12 kg / 26 lb converted
Product warranty3 years

All specifications

Show all 33 specifications

Identity

BrandPhocos · Website
ModelPSW-H-3KW-120/24V
MarketUS
Manufacturer SKUPSW-H-3KW-120/24V
About brandPhocos AG of Ulm, Germany, makes off-grid and hybrid solar equipment, including the Any-Grid PSW-H hybrid inverter chargers and PSW-B battery inverter chargers and MPPT charge controllers listed on its website. Its PSW-H manual says the inverters are made in China in an ISO 9001 and ISO 14001 certified facility.
SKU detail
locator: Datasheet Technical Data header; manual introduction and specification headers
conditions: Model number as printed on the PSW-H datasheet and in the User and Installation Manual (whose cover prints it as "PSW-H-3kW-120/24V").
Sources: [1] [2]
FieldValueConditionsSource
Weight12 kg / 26 lb converted
Printed as "12 kg / 27 lbs". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.4 Net Weight row; datasheet Weight row
[2] [1]
MPPT count1 count
Printed as "1". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.3 Number of Independent MPPTs row
[2]
Peak output2x nominal power for 5 seconds
Printed as "2x nominal power for 5 seconds" in the manual and "2x rated power for 5 seconds" on the datasheet, for all models.
Where: Manual 12.2 AC Output Surge Capacity row; datasheet Surge Power row
[2] [1]
Voltage thd< 5% for linear load, < 10% for non-linear load at nominal voltagePrinted for all models.
Where: Manual 12.2 Total Harmonic Distortion of Voltage row
[2]
AC voltage120 Vac ± 5% (programmable, 110 ~ 127 Vac)
Printed as "120 Vac ± 5% (programmable, 110 ~ 127 Vac)" for the 120 Vac models in the manual; the datasheet prints "110 ~ 127 Vac ± 5% (adjustable)" in the PSW-H-3KW-120/24V column.
Where: Manual 12.2 AC Output Voltage Regulation row, 120 Vac models; datasheet AC Output Voltage row
[2] [1]
Max charge80 A
Printed as "80 Adc" maximum battery charging current from AC in the manual; the datasheet prints 80 Adc for PV, AC and total charge current. Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.3 Max. Battery Charging Current row; datasheet Max. Total Charge Current row
[2] [1]
DimensionsW 309 × H 478 × D 143 mm / W 12.2 × H 18.8 × D 5.63 in converted Check note
The datasheet labels the same figures in a different axis order. Phocos's PSW-H datasheet (version 2024-03-25) prints these dimensions as "478 x 309 x 143 mm / 18.8 x 12.2 x 5.6 in" under the heading "Dimensions (WxHxD)", while the User and Installation Manual (version 20230515) prints the same numbers under "Housing Dimensions (H x W x D)". The manual's axis order is recorded.
Printed as "478 x 309 x 143 mm / 18.8 x 12.2 x 5.6 in" (H x W x D) in the manual. Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.4 Housing Dimensions row
[2] [1]
CommunicationsBLE; USB-OTG; CAN Bus; RS-485; RS-232; relay for generator start
Printed as "High level of connectivity: BLE, USB-OTG (on-the-go), CAN Bus, RS-485, RS-232, relay for generator start" for the series.
Where: Datasheet page 2, Product Features
[1]
Efficiency> 90
Peak efficiency from battery, printed as "> 90%" in the manual and "> 90 % peak" on the datasheet; the datasheet prints "> 96 % peak" from PV. Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.2 Peak Efficiency (from battery) row; datasheet Inverter Efficiency (from Battery) row
[2] [1]
MPPT voltage90 to 230 V
Printed as "90 Vdc ~ 230 Vdc" in the manual and "90 ~ 230 Vdc" on the datasheet. Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.3 Solar Array MPP Voltage Range row; datasheet PV Panel MPP Voltage row
[2] [1]
Solar array5 kW
Converted: 5000 Wp / 1000 W per kW = 5 kW
Printed as "5000 Wp". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.3 Max. Solar Array Power row; datasheet Max. PV Array Power row
Sources
Converted: 5000 Wp / 1000 W per kW = 5 kW
[2] [1]
Solar input4 kW
Converted: 4000 W / 1000 W per kW = 4 kW
Printed as "4000 W (2400 W for battery charging)". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.3 Max. Usable Solar Power row; datasheet Max. Usable PV Power row
Sources
Converted: 4000 W / 1000 W per kW = 4 kW
[2] [1]
AC frequency50 Hz or 60 Hz (programmable)
Printed as "50 Hz or 60 Hz (programmable)" in the manual and "50 / 60 Hz auto recognition" on the datasheet, for all models.
Where: Manual 12.2 AC Output Frequency row; datasheet AC Frequency row
[2] [1]
Max AC charge80 A
Printed as "80 Adc". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Datasheet Max. Charge Current (AC) row
[1] [2]
Max PV charge80 A
Printed as "80 Adc". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Datasheet Max. Charge Current (PV) row
[1]
Output waveformPure sine wave
Printed as "Output Waveform Pure Sine Wave" in the maker's document "PSW-H (3 kW/5 kW/6.5 kW/8 kW) Any-Grid Hybrid Inverter Charger datasheet, version 2024-03-25 (Phocos)".
Where: PSW-H (3 kW/5 kW/6.5 kW/8 kW) Any-Grid Hybrid Inverter Charger datasheet, version 2024-03-25 (Phocos), PDF page 3, Output Waveform row; spec-table row
[1]
Enclosure ratingIP21, pollution degree 2, for indoor usePrinted for all models.
Where: Manual 12.4 Ingress Protection row; datasheet Ingress Protection row
[2] [1]
Max PV current22 A
Printed as "22 Adc". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.3 Max. Usable Solar Input Current row; datasheet Max. Usable PV Current row
[2] [1]
Max PV voltage250 V
Printed as "250 Vdc, OVC II" in the manual and "250 Vdc" on the datasheet. Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.3 Max. Solar Array Open Circuit Voltage row; datasheet Max. PV Panel Voltage row
[2] [1]
Transfer time10 typical (UPS mode); 20 typical (Appliances mode); up to 50 with multiple synchronized units
Printed as "10 ms typical (UPS mode), 20 ms typical (Appliances mode) Up to 50 ms when using multiple synchronized Any-Grids" for all models.
Where: Manual 12.1 Transfer Time row; datasheet Transfer time row
[2] [1]
Apparent power3,000 VA
Printed as "3000 VA / 3000 W". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.2 Nominal AC Output Power row
[2] [1]
Nominal voltage24 V DC
Printed as "24 Vdc". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.2 Nominal Battery Input Voltage row; datasheet System Voltage row
[2] [1]
Grid passthrough38.3 A
Printed as "38.3 Aac" maximum AC input current; the manual gives the maximum AC output power in grid mode as 38.3 Aac times the AC input voltage, for example 4,596 W at 120 Vac. Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.1 Maximum AC Input Current row; datasheet Max. AC Input Current row
[2] [1]
Idle consumption< 40
Printed as "< 40 W" with AC output on and PV and AC input unavailable ("< 40 W on" on the datasheet). Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.4 Idle Self-Consumption row; datasheet Idle Self-Consumption row
[2] [1]
Max parallel units9
Printed as "Up to 9 units in parallel, 3-phase or split-phase" for this model.
Where: Datasheet Extensibility row, PSW-H-3KW-120/24V column
[1]
Continuous output3 kW
Converted: 3000 W / 1000 W per kW = 3 kW
Printed as "3000 VA / 3000 W". Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).
Where: Manual 12.2 Nominal AC Output Power row; datasheet Rated AC Output Power row
Sources
Converted: 3000 W / 1000 W per kW = 3 kW
[2] [1]
Battery compatibilityLead acid (gel, AGM, flooded), LithiumPrinted for all models.
Where: Datasheet Battery Type row
[1]
Operating temperature-10 ~ 40 °C for UL compatibility; up to 50 °C without UL compatibility Check note
The datasheet prints a single wider range. Phocos's PSW-H datasheet (version 2024-03-25) prints "Ambient Temperature -10 to +50 °C / +14 to +122 °F" for every model, without the UL condition the User and Installation Manual (version 20230515) states for the 120 Vac models. The manual's wording is recorded.
The manual prints "-10 ~ 40 °C, 14 ~ 104 °F for UL compatibility; up to 50 °C, 122 °F without UL compatibility" in a cell spanning the three 120 Vac models (read from the rendered manual page 56); the 230 Vac models print -10 ~ 50 °C.
Where: Manual 12.4 Operating Temperature Range row, 120 Vac models; datasheet Ambient Temperature row
[2] [1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
3 kW
Battery voltage
24 V DC
Solar input
5 kWMPPT trackers 1MPPT range 90 to 230 V
AC output
120 Vac ± 5% (programmable, 110 ~ 127 Vac)
Warranty
3 years
Size
21.12 L* (Calculated from published dimensions)W: 309 × H: 478 × D: 143 mm / W: 12.2 × H: 18.8 × D: 5.63 inWeight 12 kg / 26 lb

Evidence score

4/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term3 years3.6 / 30.0

3 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

The manual says Phocos warrants the product "against defects in materials and workmanship for a period of 3 years from the date of purchase" and will repair or replace a defective unit returned postage paid to Phocos; the datasheet prints "Warranty 3 years".

[2] [1]

Idle consumption< 40 · not confirmed0.0 / 10.0

Printed as "< 40 W" with AC output on and PV and AC input unavailable ("< 40 W on" on the datasheet). Read from the PSW-H-3KW-120/24V column (the last of six in the manual's tables, the first of five on the datasheet).

A value is on file but is not counted: it carries a warning or is not confirmed.

[2] [1]

Research pending, 0 points: Certificates, Battery conversion efficiency.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term3 years
The manual says Phocos warrants the product "against defects in materials and workmanship for a period of 3 years from the date of purchase" and will repair or replace a defective unit returned postage paid to Phocos; the datasheet prints "Warranty 3 years".
Where: Manual section 13.1 Conditions; datasheet Warranty row
[2] [1]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Any-Grid PSW-H User and Installation Manual, English, version 20230515 (Phocos)Official · Phocos AG · Official instruction manual · May 15, 2023 · PDF
    Source details
    Revision
    20230515
    Revision date
    May 15, 2023

    Archived copy captured on 2026-10-02.

    Location: Section 12.0 Specifications and section 13.0 Warranty

    Retrieved Oct 2, 2026

    Phocos's User and Installation Manual for the six Any-Grid PSW-H models, linked from the PSW-H product page. Its specification tables (section 12) have one column per model, with some cells spanning several models; those were read from the rendered pages.

    Archived copies

    Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup20230515 · 4.44 MB

    Archived copy, unaltered, kept as a record of what Phocos AG published. Original address: https://www.phocos.com/wp-content/uploads/2019/10/Any-Grid_PSW-H_EN-manual_2023-05-15.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2023-05-15

    Embedded creation date
    Embedded modification date
    Pages
    58

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: d45880ea9e6e88aad46fc28c21be961bab9946ee82d9462418fd8af1c05f8917

    Open
  • Datasheets

  • PSW-H (3 kW/5 kW/6.5 kW/8 kW) Any-Grid Hybrid Inverter Charger datasheet, version 2024-03-25 (Phocos)Official · Phocos AG · Official datasheet · March 25, 2024 · PDF
    Source details
    Revision
    2024-03-25
    Revision date
    March 25, 2024

    Archived copy captured on 2026-10-02.

    Location: Page 3, Technical Data

    Retrieved Oct 2, 2026

    Phocos's English datasheet for five PSW-H models, linked from the PSW-H product page. Its Technical Data table has one column per model with merged cells; those were read from the rendered page 3. It does not list the PSW-H-5KW-120/48V.

    Archived copies

    Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup2024-03-25 · 0.20 MB

    Archived copy, unaltered, kept as a record of what Phocos AG published. Original address: https://www.phocos.com/wp-content/uploads/2024/03/PSW-H-Series_english-datasheet_2024-03-25.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2024-03-25

    Embedded creation date
    Embedded modification date
    Pages
    3

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 3fdf1ea6569dae361247b4ad77fcfd65680de12baf21634a93ef8d2d8599274c

    Open
  • Other documents

  • Any-Grid Hybrid Inverter Charger Series (PSW-H) product page (Phocos, October 2, 2026 capture)Official · Phocos AG · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-02.

    Location: Downloads and Declarations & Certifications sections

    Retrieved Oct 2, 2026

    Phocos's product page for the PSW-H series, captured on October 2, 2026. It links the datasheet, the manual and a PSW-H-6.5KW-120/48V UL1741 and CSA certificate; it prints no per-model figures for the 120 Vac models.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Any-Grid PSW-H User and Installation Manual, English, version 20230515 (Phocos)

Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup20230515 · 4.44 MB

Archived copy, unaltered, kept as a record of what Phocos AG published. Original address: https://www.phocos.com/wp-content/uploads/2019/10/Any-Grid_PSW-H_EN-manual_2023-05-15.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2023-05-15

Embedded creation date
Embedded modification date
Pages
58

Embedded dates are file metadata, not independent proof of publication.

SHA-256: d45880ea9e6e88aad46fc28c21be961bab9946ee82d9462418fd8af1c05f8917

PSW-H (3 kW/5 kW/6.5 kW/8 kW) Any-Grid Hybrid Inverter Charger datasheet, version 2024-03-25 (Phocos)

Archived copy of a document published by Phocos AG. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup2024-03-25 · 0.20 MB

Archived copy, unaltered, kept as a record of what Phocos AG published. Original address: https://www.phocos.com/wp-content/uploads/2024/03/PSW-H-Series_english-datasheet_2024-03-25.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2024-03-25

Embedded creation date
Embedded modification date
Pages
3

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3fdf1ea6569dae361247b4ad77fcfd65680de12baf21634a93ef8d2d8599274c

Submit a document

Matched on printed specifications

The maker names it

  • Renon Xcellent Plus 16 kWh LiFePO4 battery (R-XC016161-US)Renon Power

    Its datasheet: Inverter dial switch codes for Renon, Schneider Gateway, Sol-Ark, Solis, Studer Xtender, Victron, SMA, Sermatec, Sofar, DEYE, Growatt SPF, Growatt SPH, Must, MEGAREVO, SAJ, Aiswei, Phocos, Voltronic Power, Afore, Lux Power and CHISAGE ESS

  • Renon Xcellent Plus 16 kWh LiFePO4 battery with heating (R-XC016161-H-US)Renon Power

    Its datasheet: Inverter dial switch codes for Renon, Schneider Gateway, Sol-Ark, Solis, Studer Xtender, Victron, SMA, Sermatec, Sofar, DEYE, Growatt SPF, Growatt SPH, Must, MEGAREVO, SAJ, Aiswei, Phocos, Voltronic Power, Afore, Lux Power and CHISAGE ESS

These are the makers’ claims.

Not documented: Battery voltage range.

Order: products a maker names first, then by Evidence score at default weights.

Matched on printed specifications only: each maker's datasheet, as recorded on the product pages. A match means one product's printed figure falls inside the other's printed limit. It does not mean the two have been shown to work together. A figure a maker does not print shows as Not documented and is never assumed. This is not a test or an approval. A qualified installer and the local code decide what can be connected.

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
PSW-H-3KW-120/24V

Manufacturer SKU PSW-H-3KW-120/24V · US market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 3
unit: Unknown
shown: 3 years
shown detail: Unknown
state: documented
points: 3.6
ceiling: 30
weight: 30
share: 12
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2] [1]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: < 40 · not confirmed
shown detail: Unknown
state: unconfirmed
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: no
reason: not-counted
reason text: A value is on file but is not counted: it carries a warning or is not confirmed.
note: Not documented.
display note: Unknown
Sources: [2] [1]

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. PSW-H (3 kW/5 kW/6.5 kW/8 kW) Any-Grid Hybrid Inverter Charger datasheet, version 2024-03-25 (Phocos) (Phocos AG · manufacturer · 2024-03-25 · observed Oct 2, 2026)
  2. Any-Grid PSW-H User and Installation Manual, English, version 20230515 (Phocos) (Phocos AG · manufacturer · 20230515 · observed Oct 2, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details