Printed as "FP1 VFXR3524A" in the first column of the For North America table of OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019), on the row "VFXR3524A, 3.5kW FLEXpower ONE". OutBack publishes no separate stock keeping number; the model designation is recorded.
Printed as "98 / 44.5" lb/kg for the FLEXpower ONE FXR in OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019), once in the Details table above both regional tables, not per model; the shipping weight is 113 lb / 51.26 kg. No battery is included.
Finished dimensions printed as "33.5 × 19.25 ×13.0 / 85 × 50 × 33" H × W × D in inches and centimeters for the FLEXpower ONE FXR in OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019), once in the Details table above both regional tables, not per model.
Printed as "VFXR3524A, 3.5kW FLEXpower ONE" in the Description column of the FP1 VFXR3524A row of OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019).
Printed as "NEMA 5-20R 250A 80A" under the Outlet, Inverter OCPD and PV OCPD columns of the FP1 VFXR3524A row of OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019); the footnote defines OCPD as overcurrent protective device. These are the breakers built into the system.
Printed as "VFXR3524A, 3.5kW FLEXpower ONE" in the Description column of the FP1 VFXR3524A row of OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019).
Printed as "98 / 44.5" lb/kg for the FLEXpower ONE FXR in OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019), once in the Details table above both regional tables, not per model; the shipping weight is 113 lb / 51.26 kg. No battery is included.
Finished dimensions printed as "33.5 × 19.25 ×13.0 / 85 × 50 × 33" H × W × D in inches and centimeters for the FLEXpower ONE FXR in OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019), once in the Details table above both regional tables, not per model.
Printed as "NEMA 5-20R 250A 80A" under the Outlet, Inverter OCPD and PV OCPD columns of the FP1 VFXR3524A row of OutBack's FLEXpower ONE FXR datasheet (#980-0047-01-00 REV C, 08/2019); the footnote defines OCPD as overcurrent protective device. These are the breakers built into the system.
Location: Page 2, For North America table, FP1 VFXR3524A row, Outlet, Inverter OCPD and PV OCPD columns
Documented
Published claims and calculations, not independent test results.
Documents
1 on file
PDF
FLEXpower ONE FXR Fully Pre-wired Single Inverter System datasheet, #980-0047-01-00 REV C, 08/2019 (OutBack Power)OfficialOutBack PowerOfficial datasheet
Source details
Revision
#980-0047-01-00 REV C
Revision date
Not stated
Archived copy captured on 2026-10-03.
Location: Page 2, FLEXpower ONE FXR Specifications, For North America table
Retrieved
OutBack Power's datasheet for the FLEXpower ONE FXR pre-wired single inverter systems, dated 08/2019, linked as the spec sheet from Signature Solar's FLEXpower ONE FXR listing and served from outbackpower.com. Its North America table lists four models; the finished dimensions and weight are printed once for the FLEXpower ONE FXR. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
FLEXpower ONE FXR Fully Pre-wired Single Inverter System datasheet, #980-0047-01-00 REV C, 08/2019 (OutBack Power)
Archived copy of a document published by OutBack Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5