About brandNorthern Electric Power (NEP) makes solar microinverters, including the BDM series, along with gateways, rapid shutdown devices and connection accessories for them.
conditions: NEP's manual cover prints "BDM-800 Microinverter" and the datasheet is titled "BDM-800 MICROINVERTER" with the part number NC0136-US-T beneath it. The manual names two North American versions, BDM-800-240A and BDM-800-208A, by grid voltage; NEP's product page sells one BDM 800 and prints no SKU. The model name is recorded; the part number is kept in the identity note.
DC circuits of BDM-800 are isolated and insulated from ground.; An integrated grounding protection circuit is included in the micro inverter.
Printed as "DC circuits of BDM-800 are isolated and insulated from ground. An integrated grounding protection circuit is included in the micro inverter."; section 4.8 adds that the unit may be grounded through the trunk cable or the racking.
The manual prints the weight as 6.4 lbs. (2.9 kg); the datasheet prints "Weight: 6.4 lbs. (2.9 kg)". The product page prints "Weight (including AC cable): 6.4 Ibs."
Where: Manual PDF page 22, Weight; datasheet, Weight
The manual's data sheet prints "Peak AC Output Power (Wp)" as 800, one figure across its columns; the datasheet prints "Peak AC Output Power: 800 W". Neither prints a duration.
Where: Manual PDF page 22, Peak AC Output Power (Wp); datasheet, Peak AC Output Power
The datasheet prints a higher THD limit. NEP's BDM-800 manual prints THD below 3% at rated power; the BDM-800 datasheet (BDM-800-20241216) prints below 5%. The manual value is recorded.
The manual's data sheet prints THD as "<3% (at rated power)".
Where: Manual PDF page 22, THD
Sources
<5% (at rated power)
The datasheet prints "THD: < 5% (at rated power)".
W 268 × H 250 × D 42 mm / W 10.6 × H 9.84 × D 1.7 in convertedCheck note
NEP's inch and millimeter dimensions disagree. NEP prints the BDM-800 as 8.8 x 8.2 x 1.38 in and as 268 x 250 x 42 mm in the same row; 8.8 x 8.2 x 1.38 in is about 224 x 208 x 35 mm. Both are shown; neither is corrected here.
The manual prints "Dimension (W-H-D)" as 8.8"x8.2"x1.38" (268x250x42 mm), and the product page prints the same row; the millimeter figures are recorded as printed. The inch figures printed beside them convert to 223.5 x 208.3 x 35.1 mm, which do not match the printed millimeters; the datasheet's drawing prints 8.2" wide, 8.8" high and 1.38" deep with no millimeters.
The manual's data sheet prints "Power Line" and section 5.1 says the BDM-800 transmits performance data through power line communication (PLC) to the BDG-256 gateway; the datasheet prints "Communications: Powerline Communications".
The manual prints "Nominal Frequency (Hz)" as 60 for the 240 Vac and 208 Vac columns and 50 for the 230 Vac column; the datasheet prints "Nominal Frequency: 60 Hz" and an allowable range of 59.3 - 60.5 Hz.
Where: Manual PDF page 22, Nominal Frequency (Hz); datasheet, Nominal Frequency
UL 1741-SA; UL 1741-SB; CSA C22.2, NO 107.1; IEC/EN 62109-1; IEC/EN 62109-2; IEEE 1547; VDE-AR-N 4105*; VDE V 0126-1-1 /A1; G83/2; CEI 21; AS 4777.2; AS 4777.3; EN50438; ABNT NBR 16149/16150
NEP's claims as printed on the datasheet ("Refer to the label for detailed information" for the grid codes); the manual's data sheet prints UL 1741, CSA C22.2 No. 107.1, IEC/EN 62109-1 and -2 and IEEE 1547. Issuer listings were not checked.
Where: Datasheet, Product Safety Compliance and Grid Code Compliance; manual PDF page 22
The manual's data sheet prints "Rated AC Output Power (Wp)" as 768 in the 240 Vac column, 700 in the 208 Vac column and 750 in the 230 Vac column; the 240 Vac figure, 768 W, is expressed in kW. The datasheet prints "Max Continuous Output Power" as 768 W at 240 Vac, 700 W on 208 Vac three phase and 800 W on 480Y/277 Vac three phase.
Where: Manual PDF page 22, Data Sheets, Rated AC Output Power (Wp), 240 Vac column; datasheet, Max Continuous Output Power
The manual prints "Rated Output Current (Aac)" as 3.2 (240 Vac), 3.36 (208 Vac) and 3.26 (230 Vac); the datasheet prints 3.2A at 240 Vac and 3.36 A on 208 Vac three phase. The 240 Vac figure is the value.
Where: Manual PDF page 22, Rated Output Current (Aac), 240 Vac column; datasheet, Rated Output Current
The manual prints "Max DC Input Current (Adc)" as "17 × 2", 17 A for each of the two DC inputs; the datasheet linked from the product page prints "17 x 2 A". NEP's earlier datasheet edition (BDM-800-110824) prints "Max DC Input Current: 20 x 2 A".
Where: Manual PDF page 22, Max DC Input Current (Adc); datasheet, Max DC Input Current
The datasheet prints a higher short-circuit current. NEP's BDM-800 installation manual prints an absolute maximum Isc of 20 A x 2; NEP's BDM-800 datasheet (NC0136-US-T, BDM-800-20241216) prints 25 A x 2. The manual value is recorded.
The manual prints "Isc PV (absolute maximum) (Adc)" as "20 × 2", 20 A for each of the two DC inputs.
Where: Manual PDF page 22, Isc PV (absolute maximum) (Adc)
Sources
25 A
The datasheet linked from the product page prints "Max Isc Current: 25 x 2 A" (25 A per input); its earlier edition prints "ISC PV (Absolute Maximum): 25 x 2 A".
The manual prints "Operating Temperature" as "-40°F to +185°F (-40°C to +85°C)"; the ambient temperature is printed separately as -40°C to +65°C. The datasheet prints the same two ranges.
Where: Manual PDF page 22, Operating Temperature; datasheet, Operating Temperature
NEP's product page prints a lower CEC efficiency. NEP's BDM-800 manual and datasheet print a CEC weighted efficiency of 96.5%; NEP's BDM 800 product page prints 95.5%. The manual value is recorded.
The manual prints "Weighted Averaged Efficiency (CEC)" as 96.50%; the datasheet prints "Weighted Average Efficiency (CEC): 96.5%".
Where: Manual PDF page 22, Weighted Averaged Efficiency (CEC); datasheet, Weighted Average Efficiency (CEC)
Sources
95.5 %
NEP's product page prints "Weighted Averaged Efficiency (CEC) 95.50%" and "High efficiency with 95.5% CEC."
The manual's data sheet prints "Nominal Power Grid Voltage (Vac)" as 240, 208 and 230 and "Allowable Power Grid Voltage (Vac)" as "211-264*", "183-228*" and "configurable*"; the 230 Vac column is not a North American version. Section 4.5 of the manual lists the BDM-800-240A and BDM-800-208A for North America with "240 Volt AC Single Phase" 211 to 264 Vac and "208 Volt AC Single Phase" 183 to 229 Vac. The datasheet prints 240 Vac (211-264 Vac) and describes the 208 Vac connection as three phase (183-228 Vac); it also lists a 480Y/277 Vac three-phase column (243-305 Vac, 800 W), which the manual does not.
Where: Manual PDF page 22, Nominal and Allowable Power Grid Voltage (Vac), 240 Vac and 208 Vac columns; manual section 4.5 (PDF page 10)
Not statedMPPT trackersNot statedMPPT range22 to 55 V
AC output
Not stated
Warranty
25 years
Size
2.81 L* (Calculated from published dimensions)W: 268 × H: 250 × D: 42 mm / W: 10.6 × H: 9.84 × D: 1.7 inWeight2.9 kg / 6.4 lb
Evidence score
30/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term25 years30.0 / 30.0
This is the best documented for an inverter, printed by the maker. 47 inverters share this value.
The manual's warranty (revision January 1, 2023) prints "Microinverters, macro-inverters and PV panel level rapid shutdown devices limited warranty coverage is 25 years unless the original purchase is for the lower cost 10-year warranty option." Microinverters not connected to NEP's data monitoring platform for their full operating life have a ten-year limited warranty, and the period starts on the activation date on that platform (or the shipment date if monitoring is not activated). The warranty applies to NEP products purchased, shipped and installed in the United States.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
25 years
25 years (10 years for the lower cost option or without NEP monitoring)
The manual's warranty (revision January 1, 2023) prints "Microinverters, macro-inverters and PV panel level rapid shutdown devices limited warranty coverage is 25 years unless the original purchase is for the lower cost 10-year warranty option." Microinverters not connected to NEP's data monitoring platform for their full operating life have a ten-year limited warranty, and the period starts on the activation date on that platform (or the shipment date if monitoring is not activated). The warranty applies to NEP products purchased, shipped and installed in the United States.
Where: Manual section 11, Warranty and Production Information (PDF page 23)
NEP's installation and operation manual for the BDM-800, linked as "Download installation manual" from NEP's BDM 800 product page, captured on October 17, 2026. Its file name reads BDG-800, but the cover and every section print BDM-800; it names the North American versions BDM-800-240A and BDM-800-208A (section 4.5). Its data sheet (section 8, PDF page 22), the AC range table on PDF page 10 and the warranty (PDF page 23) are images with no text layer; they were read from the page images. The data sheet has three output columns (240 Vac, 208 Vac and 230 Vac); only the 240 Vac and 208 Vac columns describe the North American versions. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
NEP's one-page BDM-800 datasheet, linked as "Download datasheet" from NEP's BDM 800 product page, captured on October 17, 2026. Its file name reads "BDM-800 (T) Datasheet"; the sheet itself is titled "BDM-800 MICROINVERTER" with the part number NC0136-US-T beneath. Its output table has a 240 Vac column and two three-phase columns (208 Vac and 480Y/277 Vac); its text layer runs the columns together, so each value was also read from the page image. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
NEP's own BDM 800 product page on northernep.com, captured on October 17, 2026; the content is whatever the address served on that date. Its Product characteristics table repeats the manual's data sheet but misprints several rows (it prints 768 / 700 / 750 under Nominal Power Grid Voltage and 800 under Rated AC Output Power), and its summary icons print figures that no NEP document prints for this model ("I max 12 Amps", "V red 120 Volts AC"); those rows are not used. It is read for the photograph, the cooling line, the document links and the CEC efficiency it prints, which differs from both documents. Manufacturer claims, not independent tests.
An earlier edition of NEP's BDM-800 datasheet (footer BDM-800-110824), linked from the downloads list on NEP's products page, captured on October 17, 2026. It carries the same title and part number (NC0136-US-T) as the edition linked from the product page; it is read only to show that the part number is not new to the later edition, and for the input current it prints, which differs. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Northern Electric Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.