MPP Solar PIP 2424MSE1 2400W 24V 230V Off-Grid Inverter Charger with 40A MPPT

Brand
MPP Solar
Model
2424MSE1
SKU / part number
2424MSE1 [1] [2]
Category
Inverters

chargedreviews.com/inverters/mpp-solar-2424mse1

AC output

Continuous output
2.4 kW [3] [2]
Peak output
2* rated power for 5 seconds [3] [2]
AC configuration
?
AC output voltage
230Vac± 5% [3] [2]
AC frequency
50Hz [3]
Grid pass-through
?
Maximum output per leg
?

Battery

Battery voltage
24 V [3] [2]
Battery voltage range
?
Maximum charge current
60 A [3]
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
25 A [3] [2]
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
?
Maximum PV voltage (Voc)
102 V [3]
MPPT voltage range
30 to 80 V [3] [2]
MPPT trackers
?
String inputs per MPPT
?
PV current per MPPT
?
PV short-circuit current
?
PV startup voltage
?

Efficiency and modes

Peak efficiency
93 % [3]
CEC weighted efficiency
?
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
?
Transfer time
10ms typical (UPS); 20ms typical (Appliances) [3] [2]
Idle consumption
25 W [3] [2]
Parallel units
?

Communication and environment

Communications
USB; RS-232 [3]
Operating temperature
-10 to 50 °C / 14 to 122 °F converted [3]
Enclosure rating
?
Operating noise
?

Mechanical

Dimensions
W 257.6 × H 320 × D 88 mm / W 10.14 × H 12.6 × D 3.5 in converted [3]
Weight
5.7 kg / 13 lb converted [3]

Installation (from the manual)

Torque

AC terminal torque
0.5 N·m [3]
Battery terminal torque
2 N·m [3]
PV terminal torque
1.2 N·m [3]
Ground terminal torque
?

Conductors

Battery conductors
1 x 4AWG (25 mm2) [3]
AC input conductors
12 AWG (4 mm2) [3]
AC output conductors
?
PV conductors
1 x 8AWG (10 mm2) [3]
Ground conductor
?

Protection

AC input breaker
32A [3]
AC output breaker
?
Battery fuse or breaker
One piece of 150A fuse is provided as over-current protection for the battery supply. [3]
PV disconnect
?

Clearances and orientation

Installation clearances
approx. 20 cm to the side and approx. 50 cm above and below the unit [3]
Mounting orientation
The recommended installation position is to be adhered to the wall vertically. [3]

Not in the manual: Grounding, Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

MPP Solar PIP 2424MSE1 2400W 24V 230V Off-Grid Inverter Charger with 40A MPPT · 2424MSE1

Warranty

Warranty term?
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?

Documents and sources

  1. MPP Solar product page: PIP-HSE/MSE/HSE1/MSE1 Series (October 15, 2026 capture) Manufacturer product page (HTML capture) · Checked Oct 15, 2026 https://www.mppsolar.com/v3/pip-hsemse-series/
  2. MPP Solar catalog: PIP HSE1/MSE1 Series, 2424HSE1 and 2424MSE1 (October 15, 2026 capture) Manufacturer datasheet (PDF) · Checked Oct 15, 2026 https://www.mppsolar.com/v3/catalogs/PIP-HSE1_MSE1.pdf
  3. MPP Solar user manual: PIP-HSE1/MSE1 3KVA Inverter / Charger (file dated 20190717) (October 15, 2026 capture) Manufacturer user manual (PDF) · Revised Jul 17, 2019 · Checked Oct 15, 2026 http://www.mppsolar.com/manual/PIP-HSE,MSE_HSE1,MSE1/PIP-HSE1_MSE1%20manual-20190717.pdf

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/mpp-solar-2424mse1Some links pay us a commission. That does not affect what we record.