25 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart
Printed as "<25W", an upper bound. Printed as a bound: less than 25 W, as printed.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: MPP Solar PIP 2424MSE1, the product photo on the cover of MPP Solar's PIP-HSE1/MSE1 Series catalog sheet, printed above the labels 2424HSE1 and 2424MSE1 (one photo for both models). Cropped to the unit; the labels and headings are left out. Figure from the manufacturer's document, page 1.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 5.7 kg / 13 lb converted | Net weight of the MPPT model. Where: Manual PDF page 29, Table 4, Net Weight (MPPT model) Sources5.8 kg The catalog prints "Net Weight 5.5Kg 5.8Kg"; 5.8Kg is the 2424MSE1 column and differs from the manual's 5.7 kg. [2] | [3] |
| Peak output | 2* rated power for 5 seconds | The catalog prints "Surge Rating 2X". Where: Manual PDF page 28, Table 2, Surge Capacity | [3] [2] |
| AC voltage | 230Vac± 5% | The catalog prints "Output Voltage 230VAC±5%". Where: Manual PDF page 28, Table 2, Output Voltage Regulation | [3] [2] |
| Max charge | 60 A | Printed in the MPPT rows; the default setting is 40A for the MPPT model (PDF page 15). Where: Manual PDF page 29, MPPT Solar Charging Mode, Max Charging Current (AC charger plus solar charger) | [3] |
| PV wire size | 1 x 8AWG (10 mm2) | One 8 AWG cable, 10 mm2; the manual asks for a separate DC circuit breaker between inverter and PV modules. Where: Manual PDF page 9, PV Connection cable table | [3] |
| Clearances | approx. 20 cm to the side and approx. 50 cm above and below the unit | Printed by the manual. Where: Manual PDF page 6, Mounting the Unit | [3] |
| Dimensions | W 257.6 × H 320 × D 88 mm / W 10.14 × H 12.6 × D 3.5 in converted | Printed as D*W*H in mm. The catalog prints "Dimension 320*258*88mm". Where: Manual PDF page 29, Table 4, Dimension (D*W*H) | [3] |
| Communications | USB; RS-232 | Ports named in the product overview; the catalog prints "USB / RS232 communication interface". Where: Manual PDF page 5, Product Overview | [3] |
| Efficiency | 93 % Peak, inverter mode | Peak efficiency in inverter mode; the manual also prints "Efficiency (Line Mode) >95%". Where: Manual PDF page 28, Table 2, Peak Efficiency Sources95 % The catalog prints "Peak Efficiency 95%", which differs from the manual's 93%. [2] | [3] |
| MPPT voltage | 30 to 80 V | The catalog prints 30 ~ 80V in the 2424MSE1 column. Where: Manual PDF page 29, MPPT Solar Charging Mode, PV Array MPPT Voltage Range | [3] [2] |
| AC frequency | 50Hz | The specification table prints 50Hz; program 09 offers 50Hz (default) or 60Hz. Where: Manual PDF page 28, Table 2, Output Frequency; PDF page 16, program 09 Sources50Hz / 60Hz The catalog prints "Input/Output Frequency 50Hz / 60Hz", which differs from the manual's specification table. [2] | [3] |
| Max AC charge | 25 A | 25Amp at 230Vac input; program options are 15A and 25A (default). Where: Manual PDF page 29, Utility Charging Mode, AC Charging Current (Max) | [3] [2] |
| Max PV charge | 40 A | 40Amp in the MPPT rows; the catalog prints 40A in the 2424MSE1 column and the series page "40A MPPT". Where: Manual PDF page 29, MPPT Solar Charging Mode, Charging Current | [3] [2] |
| Output waveform | Pure Sine Wave | Printed by the manual and the catalog. Where: Manual PDF page 28, Table 2, Output Voltage Waveform | [3] [2] |
| AC input breaker | 32A | Printed for the 3KVA. Where: Manual PDF page 8, AC Input/Output Connection | [3] |
| Max PV voltage | 102 V | Printed in the MPPT rows. Where: Manual PDF page 29, MPPT Solar Charging Mode, Max. PV Array Open Circuit Voltage Sources105 V The catalog prints "Max PV Input Voc 80V 105V"; 105V is the 2424MSE1 column and differs from the manual's 102Vdc. [2] | [3] |
| Surge duration s | 5 s | Duration printed with the surge capacity. Where: Manual PDF page 28, Table 2, Surge Capacity | [3] |
| Transfer time | 10ms typical (UPS); 20ms typical (Appliances) | The catalog prints "<10ms (UPS mode), <20ms (Appliance mode)". Where: Manual PDF page 27, Table 1 Line Mode Specifications, Transfer Time | [3] [2] |
| Apparent power | 3,000 VA | Printed as 3KVA. Where: Manual PDF page 28, Table 2, Rated Output Power SourcesConverted: 3 kVA x 1000 VA per kVA = 3000 VA | [3] [2] |
| Battery wire size | 1 x 4AWG (25 mm2) | One 4 AWG cable, 25 mm2; strip 18 mm and use bootlace ferrules (manual). Where: Manual PDF page 7, Recommended battery cable size | [3] |
| Nominal voltage | 24 V | 24Vdc; the catalog prints 24V. Where: Manual PDF page 28, Table 2, Nominal DC Input Voltage | [3] [2] |
| AC input wire size | 12 AWG (4 mm2) | The AC wire table applies to the AC input and output connection. Where: Manual PDF page 8, AC cable table | [3] |
| AC terminal torque | 0.5 N·m | Printed as "0.5 Nm". Where: Manual PDF page 8, AC cable table | [3] |
| Battery protection | One piece of 150A fuse is provided as over-current protection for the battery supply. | Printed by the manual; it still asks for a separate DC over-current protector (PDF page 7). Where: Manual PDF page 3, safety instructions | [3] |
| Idle consumption | 25 W less than 25 W, as printed | Printed as "<25W", an upper bound. Where: Manual PDF page 28, Table 2, No Load Power Consumption | [3] [2] |
| PV terminal torque | 1.2 N·m | Printed as "1.2 Nm". Where: Manual PDF page 9, PV Connection cable table | [3] |
| Continuous output | 2.4 kW | The manual prints "Rated Output Power 3KVA/2.4KW"; the catalog prints "Continuous Output 3KVA / 2400W". The real power is recorded. Manufacturer claim, not an independent test. Where: Manual PDF page 28, Table 2 Inverter Mode Specifications, Rated Output Power | [3] [2] |
| Mounting orientation | The recommended installation position is to be adhered to the wall vertically. | Printed with "SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY." and an ambient temperature between 0°C and 55°C. The series page says indoor installation only. Where: Manual PDF page 6, Mounting the Unit | [3] |
| Storage temperature | -15 to 60 °C / 5 to 140 °F converted | Printed by the manual; the catalog prints the same. Where: Manual PDF page 29, Table 4, Storage temperature | [3] |
| Battery terminal torque | 2 N·m | Printed as "2 Nm" in the steps and in the battery cable table. Where: Manual PDF page 7, Battery Connection | [3] |
| Operating temperature | -10 to 50 °C / 14 to 122 °F converted | Printed by the manual. Where: Manual PDF page 29, Table 4 General Specifications, Operating Temperature Range Sources0 to 55 °C The catalog prints "Operating/Storage Temp. 0°C ~ 55°C / -15°C~ 60°C"; the operating range differs from the manual's -10°C to 50°C. [2] | [3] |
| Other compliance claims | CE | Printed by the catalog as a claim; no certificate was checked. Where: Catalog ENVIRONMENTAL / MECHANICAL SPECIFICATIONS, Certification | [2] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
25 against 8 W, the lowest documented for an inverter in the 1.5 to 3.5 kW output band (printed by the maker): Victron Energy Inverter 12/2000 Smart
Printed as "<25W", an upper bound. Printed as a bound: less than 25 W, as printed.
Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
Unknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Archived copy captured on 2026-10-15.
Location: SPECIFICATIONS, Tables 1 to 4 (PDF pages 27 to 29); installation (PDF pages 6 to 10)
Retrieved Oct 15, 2026
The user manual the Download Center links for the PIP-HSE1/MSE1 economy series, captured on October 15, 2026; the primary source for the 2424MSE1. It names the model only as 3KVA and prints PWM and MPPT rows; the MPPT rows are the 2424MSE1's. Manufacturer claims, not independent tests.
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what MPP Solar Inc. published. Original address: http://www.mppsolar.com/manual/PIP-HSE,MSE_HSE1,MSE1/PIP-HSE1_MSE1%20manual-20190717.pdf. Copyright and takedown
Printed revision date: 2019-07-17
Embedded dates are file metadata, not independent proof of publication.
SHA-256: a53d9a44408c69c731da08865de3cdfa1eadae5f17d815b289bf9557d6aeefb6
Archived copy captured on 2026-10-15.
Location: ELECTRICAL SPECIFICATION and SOLAR CHARGER tables, page 1
Retrieved Oct 15, 2026
MPP Solar's one-page catalog for the 2424HSE1 (PWM) and 2424MSE1 (MPPT), linked from the Download Center and captured on October 15, 2026. Rows with two values are read in the 2424MSE1 column (the second); rows with one value apply to both. Manufacturer claims, not independent tests.
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what MPP Solar Inc. published. Original address: https://www.mppsolar.com/v3/catalogs/PIP-HSE1_MSE1.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: f2144c19e180b4599a7edbca9089321429dc6dc1f2fd2b8abdfa32589d15f4bf
Archived copy captured on 2026-10-15.
Location: Overview and model list
Retrieved Oct 15, 2026
MPP Solar's series page for the PIP-HSE, MSE, MSXE, HSE1 and MSE1 inverters, captured on October 15, 2026. It names each model with its rating and says the series omits parallel operation. The page carries no revision date.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy captured on 2026-10-15.
Location: Model list; TERM DEFINITION; LEGACY MODELS
Retrieved Oct 15, 2026
MPP Solar's Download Center at www.mppsolar.com, captured on October 15, 2026. It lists each model with its maker label (off-grid or hybrid, defined on the page) and links its catalog and user manual; models no longer current are listed under LEGACY MODELS with "(legacy)". The page carries no revision date.
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what MPP Solar Inc. published. Original address: http://www.mppsolar.com/manual/PIP-HSE,MSE_HSE1,MSE1/PIP-HSE1_MSE1%20manual-20190717.pdf. Copyright and takedown
Printed revision date: 2019-07-17
Embedded dates are file metadata, not independent proof of publication.
SHA-256: a53d9a44408c69c731da08865de3cdfa1eadae5f17d815b289bf9557d6aeefb6
Archived copy of a document published by MPP Solar Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what MPP Solar Inc. published. Original address: https://www.mppsolar.com/v3/catalogs/PIP-HSE1_MSE1.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: f2144c19e180b4599a7edbca9089321429dc6dc1f2fd2b8abdfa32589d15f4bf
No sourced accessories or replacement parts listed yet.
Manufacturer SKU 2424MSE1
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 10 basis: Unknown missing: Certificate evidence needed Warranty term needed Battery conversion efficiency needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Listing stated, none checked shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: 25 unit: Unknown shown: 25 W shown detail: Unknown state: documented points: 3.2 ceiling: 10 weight: 10 share: 32 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Printed as a bound: less than 25 W, as printed. display note: Unknown | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details