About brandHoymiles Power Electronics makes microinverters, single- and three-phase hybrid inverters and module-level rapid shutdown hardware; its North American single-phase hybrid line is sold as the HYS-LV-USG1 series.
SKU detail
locator: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Model row, MIT-4000-8TL column (fourth of 6)
conditions: Hoymiles' own model name, printed in the Model row of the manual's technical table ("Model MIT-4000-8T MIT-4500-8T MIT-5000-8T MIT-4000-8TL MIT-4500-8TL MIT-5000-8TL").
Printed as "Weight (kg) 9", one cell shared by all 6 models.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Mechanical Data, Weight, one cell shared by all 6 models
Printed as "Number of MPPTs 4" with "Number of inputs per MPPT 1", one cell shared by all 6 models. The manual's model identifier gives the "8" in the model name as the maximum number of PV modules connected.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Input Data (DC), Number of MPPTs, one cell shared by all 6 models
W 395 × H 308 × D 60 mm / W 15.6 × H 12.1 × D 2.4 in converted
Printed as "Dimensions (W × H × D [mm]) 395 × 308 × 60", width by height by depth, one cell shared by all 6 models.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Mechanical Data, Dimensions, one cell shared by all 6 models
Printed as "Communication Sub-1G" with "Topology Transformerless", one cell shared by all 6 models; monitoring through S-Miles Cloud (Hoymiles Monitoring Platform).
Where: Hoymiles' Global user manual (REV1.8), PDF page 36 (printed page 32), section 8 Technical Data, Features, Communication, one cell shared by all 6 models
Printed as 97.00% in the MIT-4000-8TL column of the row "Peak efficiency 97.40% 97.40% 97.40% 97.00% 97.00% 97.00%". A nominal MPPT efficiency of 99.80% is also printed, not recorded here. A manufacturer claim.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Efficiency, Peak efficiency, MIT-4000-8TL column (fourth of 6)
Printed as "12-120" in the MIT-4000-8TL column of the row "MPPT voltage range (V) 12-136 12-136 12-136 12-120 12-120 12-120". A separate peak power MPPT voltage range is printed per model.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Input Data (DC), MPPT voltage range (V), MIT-4000-8TL column (fourth of 6)
Printed as "Outdoor-IP67", one cell shared by all 6 models.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Mechanical Data, Enclosure rating, one cell shared by all 6 models
Printed as 120 V in the MIT-4000-8TL column of the row "Maximum input voltage (V) 140 140 140 120 120 120".
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Input Data (DC), Maximum input voltage (V), MIT-4000-8TL column (fourth of 6)
Rated output power 4000 VA, printed in the MIT-4000-8TL column of the row "Rated output power (VA) 4000 4500 5000 4000 4500 5000". No separate peak or maximum continuous output figure is printed.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Output Data (AC), Rated output power (VA), MIT-4000-8TL column (fourth of 6)
Printed as "32/120" in the MIT-4000-8TL column of the row "Minimum/Maximum start-up voltage (V) 32/136 32/136 32/136 32/120 32/120 32/120": the 32 V minimum start-up voltage is recorded; the 120 V maximum is not recorded as a separate figure.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Input Data (DC), Minimum/Maximum start-up voltage (V), MIT-4000-8TL column (fourth of 6)
EN 50549-1: 2019; EN 50549-10:2022; IEC/EN 62109-1/-2; IEC/EN 61000-6-1/-2/-3/-4; IEC/EN 61000-3-2/-3; UL 3741
Compliance row as printed by Hoymiles, one cell shared by all 6 models: "EN 50549-1: 2019, EN 50549-10:2022" on one line and "IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 61000-3-2/-3, UL 3741" on the next. Manufacturer claims; no certificate or listing directory was checked.
Where: Hoymiles' Global user manual (REV1.8), PDF page 36 (printed page 32), section 8 Technical Data, Features, Compliance, one cell shared by all 6 models
Printed as "Maximum input current (A) 4 × 20", one cell shared by all 6 models: 4 inputs at 20 A each; the per-input figure is recorded.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Input Data (DC), Maximum input current (A), one cell shared by all 6 models
Printed as "Maximum input short circuit current (A) 4 × 25", one cell shared by all 6 models: 4 inputs at 25 A each; the per-input figure is recorded.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Input Data (DC), Maximum input short circuit current (A), one cell shared by all 6 models
Printed as "Ambient temperature range (℃) -40 to +65", one cell shared by all 6 models.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Mechanical Data, Ambient temperature range, one cell shared by all 6 models
Printed as 95.70% in the MIT-4000-8TL column of the row "EU weighted efficiency 96.10% 96.30% 96.40% 95.70% 95.90% 96.10%" (EU weighted, not CEC weighted). A manufacturer claim.
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Efficiency, EU weighted efficiency, MIT-4000-8TL column (fourth of 6)
Three-phase, 230/400 V, 3L+N+PE, 50/60 Hz (45 to 55 Hz or 55 to 65 Hz range)
Printed as "Grid type Three Phase", "Nominal output voltage (V) 230/400, 3L+N+PE", "Nominal frequency (Hz)* 50/60" and "Nominal range (Hz)* 45-55 / 55-65", one cell shared by all 6 models. The footnote reads "The parameter may vary depending on local requirements."
Where: Hoymiles' Global user manual (REV1.8), PDF page 35 (printed page 31), section 8 Technical Data, Output Data (AC), grid type, nominal output voltage and frequency, one cell shared by all 6 models
7.3 L* (Calculated from published dimensions)W: 395 × H: 308 × D: 60 mm / W: 15.6 × H: 12.1 × D: 2.4 inWeight9 kg / 20 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
Archived copy captured from Hoymiles' file host w3oss.hoymiles.com on October 10, 2026 at 03:42:45 UTC, obtained by Alternative Research by following the file link on Hoymiles' openly served download page https://www.hoymiles.com/downloads/hoymiles-user-manual-mit-5000-8t-series-global-en.html. The copy read hashes to the SHA-256 recorded for this source.
Retrieved Oct 9, 2026
Hoymiles' own user manual for the MIT-5000-8T series, cover printed "USER MANUAL Region: Global REV1.8", valid for the MIT-4000-8T, MIT-4500-8T, MIT-5000-8T and the low input voltage MIT-4000-8TL, MIT-4500-8TL and MIT-5000-8TL. Read in full; its section 8 Technical Data table (PDF pages 35 and 36, printed pages 31 and 32, one column per model) was also checked on the rendered page and is the primary source for these six models. Hoymiles links this file from its own openly served download page https://www.hoymiles.com/downloads/hoymiles-user-manual-mit-5000-8t-series-global-en.html, where it was obtained; the file itself is on Hoymiles' file host at https://w3oss.hoymiles.com/uploadfile/1/202608/8d8f13cba3.pdf, which serves it only to requests that come from a hoymiles.com page. Manufacturer claims, not an independent test.
Archived copies
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Hoymiles User Manual, Three-phase Microinverter MIT-4000-8T, MIT-4500-8T, MIT-5000-8T, MIT-4000-8TL, MIT-4500-8TL and MIT-5000-8TL, Region: Global, REV1.8
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.