About brandHoymiles Power Electronics makes microinverters, single- and three-phase hybrid inverters and module-level rapid shutdown hardware; its North American single-phase hybrid line is sold as the HYS-LV-USG1 series.
SKU detail
locator: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Model row, MIS-500-1A column (fifth of 5)
conditions: Hoymiles' own model name, printed in the Model row of the technical table ("Model MIS-300-1A MIS-350-1A MIS-400-1A MIS-450-1A MIS-500-1A") of the Europe data sheet.
W 224.2 × H 165.3 × D 28.5 mm / W 8.83 × H 6.51 × D 1.12 in converted
Printed as "Dimensions (W × H × D) [mm] 224.2 x 165.3 x 28.5 (without bracket)", width by height by depth, without bracket, one cell shared by all 5 models.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Mechanical Data, Dimensions, one cell shared by all 5 models
Printed as "Peak efficiency 97.50%", one cell shared by all 5 models. A nominal MPPT efficiency of 99.80% is also printed, not recorded here. A manufacturer claim.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Efficiency, Peak efficiency, one cell shared by all 5 models
Printed as "MPPT voltage range (V) 16 to 58", one cell shared by all 5 models. A separate peak power MPPT voltage range is printed per model.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Input Data (DC), MPPT voltage range (V), one cell shared by all 5 models
Printed as 65 V in the MIS-500-1A column of the row "Maximum input voltage (V) 60 60 65 65 65".
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Input Data (DC), Maximum input voltage (V), MIS-500-1A column (fifth of 5)
Peak output power 500 VA, printed in the MIS-500-1A column of the row "Peak output power (VA) 300 350 400 450 500". No rated or continuous output power is printed; a maximum continuous output current is printed per model.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Output Data (AC), Peak output power (VA), MIS-500-1A column (fifth of 5)
Printed as "Start-up voltage (V) 22", one cell shared by all 5 models.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Input Data (DC), Start-up voltage (V), one cell shared by all 5 models
EN 50549-1: 2019; EN 50549-10: 2022; NF EN 50549-1: 2019; TOR 2019; CEI 0-21: 2024; UNE 217002/NTS V2.1; RD 647/2020; VDE-AR-N 4105: 2018; UL 1741; IEC/EN 62109-1/-2; IEC/EN 61000-6-1/-2/-3/-4; IEC/EN 61000-3-2/-3
Compliance row as printed by Hoymiles, one cell shared by all 5 models: "EN 50549-1: 2019, EN 50549-10: 2022, NF EN 50549-1: 2019, TOR 2019, CEI 0-21: 2024, UNE 217002/NTS V2.1, RD 647/2020, VDE-AR-N 4105: 2018, UL 1741, IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 61000-3-2/-3". Manufacturer claims; no certificate or listing directory was checked.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Features, Compliance, one cell shared by all 5 models
Printed as 16 A in the MIS-500-1A column of the row "Maximum input current (A) 12 13 14 15 16"; the unit has one input.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Input Data (DC), Maximum input current (A), MIS-500-1A column (fifth of 5)
Printed as 25 A in the MIS-500-1A column of the row "Maximum input short circuit current (A) 20 20 25 25 25".
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Input Data (DC), Maximum input short circuit current (A), MIS-500-1A column (fifth of 5)
Printed as "Operating temperature range (℃) -40 to +65", one cell shared by all 5 models.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Mechanical Data, Operating temperature range, one cell shared by all 5 models
Printed as "European weighted efficiency 96.70%" (European weighted, not CEC weighted), one cell shared by all 5 models. A manufacturer claim.
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Efficiency, European weighted efficiency, one cell shared by all 5 models
230 V nominal (180 to 275 V range), 50 Hz nominal (45 to 55 Hz range); single-phase
Printed as nominal output voltage/range 230/180 to 275 V and nominal frequency/range 50/45 to 55 Hz, one cell shared by all 5 models. The footnote reads "Nominal voltage/frequency range can vary depending on local requirements."
Where: Hoymiles' Europe data sheet (V202408), PDF page 2, Technical Specifications, Output Data (AC), nominal output voltage and frequency, one cell shared by all 5 models
1.06 L* (Calculated from published dimensions)W: 224.2 × H: 165.3 × D: 28.5 mm / W: 8.83 × H: 6.51 × D: 1.12 inWeight1.1 kg / 2.4 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
Archived copy captured from www.hoymiles.com on October 10, 2026 at 02:09:15 UTC, obtained by Alternative Research from the file linked on Hoymiles' download page https://www.hoymiles.com/downloads/datasheet-mis-300-amp-350-amp-400-amp-450-amp-500-1a-eu-en.html. The copy read hashes to the SHA-256 recorded for this source.
Retrieved Oct 9, 2026
Hoymiles' own two-page data sheet for the MIS-300-1A, MIS-350-1A, MIS-400-1A, MIS-450-1A and MIS-500-1A microinverters for AC module applications, printed "Region: Europe V202408". Read in full; its Technical Specifications table (PDF page 2) was also checked on the rendered page and is the only source for these records (no user manual for them is in the captured files). Hoymiles links this file from its own download page https://www.hoymiles.com/downloads/datasheet-mis-300-amp-350-amp-400-amp-450-amp-500-1a-eu-en.html (the page's file link is https://www.hoymiles.com/uploadfile/1/202506/0906039d26.pdf); the same file is served openly at https://www.hoymiles.com/uploadfile/1/202506/0906039d26.pdf, the address this copy was taken from. Manufacturer claims, not an independent test.
Archived copies
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].