95 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
Printed as "95.0%" in the HYS-8.0LV-EUG2 column. Manufacturer claim.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Maker series photo: Hoymiles HYS-(8-12)LV-EUG2 single-phase hybrid inverter series, from Hoymiles' product page for the series (captured November 2, 2026), which covers the HYS-8.0LV-EUG2 and the other models of the series with one set of images; not specific to this model. Shown on a white background.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Cooling | Smart cooling | Printed once for every model as "Cooling Smart cooling". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Cooling | [1] |
| Weight | 41 kg / 90 lb converted | Printed once for every model as "Weight (kg) 41". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Weight (kg) | [1] |
| MPPT count | 2 | Printed as "2/4" in the HYS-8.0LV-EUG2 column: 2 MPPTs and at most 4 input strings. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), PV Input, MPPT number/Max. input strings number | [1] |
| Peak output | 16000 VA for 10 s (off-grid output) | Printed as "16000, 10s" in the HYS-8.0LV-EUG2 column of the off-grid "Max. output apparent power (VA)". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), AC Output (Off-grid), Max. output apparent power (VA) | [1] |
| Max charge | 160 A | Printed as "160/160" in the HYS-8.0LV-EUG2 column: 160 A charge, 160 A discharge. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Battery, Max. charge/discharge current (A) | [1] |
| Dimensions | W 502 × H 740 × D 202 mm / W 19.8 × H 29.1 × D 7.95 in converted | Printed once for every model as "502 × 740 × 202", width by height by depth. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Dimensions (W × H × D [mm]) | [1] |
| Mounting type | Wall mounting | Printed once for every model as "Mounting Wall mounting". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Mounting | [1] |
| Communications | RS485; Wi-Fi (optional); Ethernet (optional); 4G (optional) | Printed once for every model as RS485 with optional Wi-Fi, Ethernet or 4G; note 2 reads "The DTS-Ethernet and DTS-4G solutions will be coming soon." The battery link is CAN. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Communication | [1] |
| Efficiency | 97.6 % | Printed as "97.6%" in the HYS-8.0LV-EUG2 column of "Max. efficiency". Manufacturer claim. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Efficiency, Max. efficiency | [1] |
| MPPT voltage | 125 to 500 V | Printed once for every model as "MPPT voltage range (V) 125-500"; the rated PV voltage is printed as 360 V. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), PV Input, MPPT voltage range (V) | [1] |
| Solar array | 10.4 kWConverted: 10400 W / 1000 W/kW = 10.4 kW | Recommended maximum PV power, printed as "10400" in the HYS-8.0LV-EUG2 column (written in kW). Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), PV Input, Recommended max. PV power (W) SourcesConverted: 10400 W / 1000 W/kW = 10.4 kW | [1] |
| Max discharge | 160 A | Printed as "160/160" in the HYS-8.0LV-EUG2 column: 160 A charge, 160 A discharge. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Battery, Max. charge/discharge current (A) | [1] |
| AC configuration | L/N/PE, 220/230 V (154 to 276 V), 50/60 Hz; off-grid output 220/230 V, 50/60 Hz | Printed once for every model as "Grid form L/N/PE", "Rated AC output voltage/Range (V) 220/230, 154-276" and "Rated grid frequency (Hz) 50/60", and for the off-grid output 220/230 V and 50/60 Hz. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), AC Input and Output (On-grid) and AC Output (Off-grid) | [1] |
| Backup output | 8 kWConverted: 8000 W / 1000 W/kW = 8 kW | Printed as "8000" in the HYS-8.0LV-EUG2 column of the off-grid "Rated output power (W)" (written in kW). Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), AC Output (Off-grid), Rated output power (W) SourcesConverted: 8000 W / 1000 W/kW = 8 kW | [1] |
| Enclosure rating | IP65 | Printed once for every model as "Protection degree IP65". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Protection degree | [1] |
| Max PV current | 32/32 | Printed as "32/32" in the HYS-8.0LV-EUG2 column: 32 A per MPPT. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), PV Input, Max. input current (A) | [1] |
| Max PV voltage | 550 V | Printed once for every model as "Max. input voltage (V) 550". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), PV Input, Max. input voltage (V) | [1] |
| Transfer time | <10 ms | Printed once for every model as "Back-up switch time (ms) <10". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), AC Output (Off-grid), Back-up switch time (ms) | [1] |
| Apparent power | 8,800 VA | Printed as "8800" in the HYS-8.0LV-EUG2 column of the on-grid "Max. output apparent power (VA)". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), AC Input and Output (On-grid), Max. output apparent power (VA) | [1] |
| Max parallel units | 10 count | Printed once for every model as "Max. parallel 10". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Max. parallel | [1] |
| PV start voltage | 150 V | Printed once for every model as "Start-up voltage (V) 150". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), PV Input, Start-up voltage (V) | [1] |
| Max charge power | 8 kWConverted: 8000 W / 1000 W/kW = 8 kW | Printed as "8000/8000" in the HYS-8.0LV-EUG2 column (written in kW). Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Battery, Max. charge/discharge power (W) SourcesConverted: 8000 W / 1000 W/kW = 8 kW | [1] |
| Operating noise | <40 dB | Printed once for every model as "Noise (dB) <40". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Noise (dB) | [1] |
| Certification claims | EN 50549; NRS 097-2-1; IEC 62109-1/-2; IEC/EN 61000-6-1/-2/-3/-4 | Grid connection and safety or EMC standards as printed once for every model. Manufacturer claims; no issuer directory was checked. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Certifications and Standards | [1] |
| Continuous output | 8 kWConverted: 8000 W / 1000 W/kW = 8 kW | Printed as "8000" in the HYS-8.0LV-EUG2 column of the on-grid "Rated output power (W)" (written in kW). Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), AC Input and Output (On-grid), Rated output power (W) SourcesConverted: 8000 W / 1000 W/kW = 8 kW | [1] |
| Max output current | 38.3 A | Printed as "38.3" in the HYS-8.0LV-EUG2 column of "Max. output current (A)". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), AC Input and Output (On-grid), Max. output current (A) | [1] |
| Battery compatibility | Li-ion (charging strategy self-adaption to BMS, CAN); lead-acid printed as supported soon | Printed once for every model as "Battery type Li-ion/Lead-acid(1)" with note 1, "Lead-acid batteries will be supported soon.", and "Charging strategy for Li-ion battery Self-adaption to BMS Charging curve 3 Stages/Equalization External temperature sensor Optional Communication CAN". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Battery | [1] |
| Battery efficiency | 95 % | Printed as "95.0%" in the HYS-8.0LV-EUG2 column. Manufacturer claim. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Efficiency, Max. battery discharge to AC efficiency | [1] |
| Max discharge power | 8 kWConverted: 8000 W / 1000 W/kW = 8 kW | Printed as "8000/8000" in the HYS-8.0LV-EUG2 column (written in kW). Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Battery, Max. charge/discharge power (W) SourcesConverted: 8000 W / 1000 W/kW = 8 kW | [1] |
| Max PV short circuit | 40/40 | Printed as "40/40" in the HYS-8.0LV-EUG2 column: 40 A per MPPT. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), PV Input, Max. short circuit current (A) | [1] |
| Battery voltage range | 40 to 60 V | Printed once for every model as "Battery voltage range (V) 40-60". Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Battery, Battery voltage range (V) | [1] |
| Operating temperature | -25 to 65 °C / -13 to 149 °F converted | Printed once for every model as "-25 to +65 (>45, derating)": derated above 45 degrees C. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), General, Operating temperature | [1] |
| Weighted efficiency | 97 % | European weighted efficiency, printed as "97.0%" in the HYS-8.0LV-EUG2 column. Manufacturer claim. Where: PDF page 2, Technical Specifications, HYS-8.0LV-EUG2 column (column 1 of 3), Efficiency, EU efficiency | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
95 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
Printed as "95.0%" in the HYS-8.0LV-EUG2 column. Manufacturer claim.
Research pending, 0 points: Certificates, Warranty term, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
Unknown: no warranty facts recorded.
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Reached from Hoymiles' download page https://www.hoymiles.com/downloads/hys-lv-eug2-series-datasheet-en.html; obtained by Alternative Research, captured Nov 1, 2026 (archived copy).
Location: PDF page 1 (features, description); PDF page 2, Technical Specifications (one column per model, HYS-8.0LV-EUG2 to HYS-12.0LV-EUG2)
Retrieved Nov 1, 2026
Hoymiles' own datasheet for the HYS-8.0LV-EUG2, HYS-10.0LV-EUG2 and HYS-12.0LV-EUG2 single-phase hybrid inverters (Region: Global, REV1.4), listed on Hoymiles' download page https://www.hoymiles.com/downloads/hys-lv-eug2-series-datasheet-en.html, which redirects to this file on Hoymiles' file host. Obtained by Alternative Research on November 2, 2026 (captured 02:02:24.174 UTC), because Hoymiles' file host answers our fetcher with a 403; each fact was checked against the printed page. Manufacturer claims, not independent tests.
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202506/80baeebc72.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 8448efa2ff0344c78d07b49f3b2283a612112a5a57c5de67f45d2f61c4ed5a39
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202506/80baeebc72.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 8448efa2ff0344c78d07b49f3b2283a612112a5a57c5de67f45d2f61c4ed5a39
No sourced accessories or replacement parts listed yet.
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 15 basis: Unknown missing: Certificate evidence needed Warranty term needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: 95 unit: Unknown shown: 95 % shown detail: Unknown state: documented points: 14.5 ceiling: 15 weight: 15 share: 96.7 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details