Charged ReviewsSaved 0Compare 0Login
Hoymiles
Microinverter

Hoymiles HMS-600-2T (Europe)

Key specs

Max PV voltage60 V
Weight3.2 kg / 7.1 lb converted
Efficiency96.7 %
Apparent power600 VA
Max PV input current12 A
Max PV short circuit20 A

All specifications

Identity

BrandHoymiles · Website
ModelHMS-600-2T
MarketEU
Manufacturer SKUHMS-600-2T
About brandHoymiles Power Electronics makes microinverters, single- and three-phase hybrid inverters and module-level rapid shutdown hardware; its North American single-phase hybrid line is sold as the HYS-LV-USG1 series.
SKU detail
locator: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Model row, HMS-600-2T column (first of 5)
conditions: Hoymiles' own model name, printed in the Model row of the technical table ("Model HMS-600-2T HMS-700-2T HMS-800-2T HMS-900-2T HMS-1000-2T") of the Europe edition.
Sources: [1] [2]
FieldValueConditionsSource
Weight3.2 kg / 7.1 lb converted
Printed as "Weight (kg) 3.2", one cell shared by all 5 models. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Mechanical Data, Weight, one cell shared by all models
[1] [2]
MPPT count2
Printed as "Number of MPPTs 2" with "Number of inputs per MPPT 1", one cell each shared by all 5 models. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Input Data (DC), Number of MPPTs, one cell shared by all models
[1] [2]
DimensionsW 261 × H 180 × D 35.1 mm / W 10.3 × H 7.09 × D 1.38 in converted
Printed as "Dimensions (W × H × D [mm]) 261 × 180 × 35.1", width by height by depth, one cell shared by all 5 models. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Mechanical Data, Dimensions, one cell shared by all models
[1] [2]
CommunicationsSub-1G
Printed as "Communication Sub-1G", one cell shared by all 5 models, with monitoring through "S-Miles Cloud (Hoymiles Monitoring Platform)"; the document says the Sub-1G wireless link communicates with the Hoymiles gateway DTU. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Features, Communication, one cell shared by all models
[1] [2]
Efficiency96.7 %
Printed as 96.7% in the HMS-600-2T column of the row "Peak efficiency 96.7% 96.7% 96.7% 96.5% 96.5%". A nominal MPPT efficiency of 99.8% is also printed, not recorded here. A manufacturer claim. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Efficiency, Peak efficiency, HMS-600-2T column (first of 5)
[1] [2]
MPPT voltage16 to 60 V
The MPPT voltage range row prints 16 to 60 V (written "16 to 60"), one cell shared by all 5 models. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Input Data (DC), MPPT voltage range (V), one cell shared by all models
[1] [2]
Enclosure ratingOutdoor, IP67
Printed as "Outdoor-IP67", one cell shared by all 5 models. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Mechanical Data, Enclosure rating, one cell shared by all models
[1] [2]
Max PV voltage60 V
Printed as 60 V in the HMS-600-2T column of the row "Maximum input voltage (V) 60 60 65 65 65". Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Input Data (DC), Maximum input voltage (V), HMS-600-2T column (first of 5)
[1] [2]
Apparent power600 VA
Rated output power 600 VA, printed in the HMS-600-2T column of the row "Rated output power (VA) 600 700 800 900 1000". No separate peak or maximum continuous output figure is printed. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Output Data (AC), Rated output power (VA), HMS-600-2T column (first of 5)
[1] [2]
PV start voltage22 V
Printed as "Start-up voltage (V) 22", one cell shared by all 5 models. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Input Data (DC), Start-up voltage (V), one cell shared by all models
[1] [2]
Certification claimsEN 50549-1:2019; EN 50549-10:2022; VDE-AR-N 4105: 2018; NF EN 50549-1:2019; NF EN 50549-10:2022; IEC/EN 62109-1/-2; IEC/EN 61000-6-1/-2/-3/-4; IEC/EN 61000-3-2/-3 Check note
The data sheet prints a different compliance list. Hoymiles' Europe user manual (REV1.1) lists EN 50549-1:2019, EN 50549-10:2022, VDE-AR-N 4105: 2018, NF EN 50549-1:2019, NF EN 50549-10:2022 and the IEC/EN 62109 and 61000 standards; Hoymiles' Europe data sheet (V202408) lists EN 50549-1: 2019, VDE-AR-N 4105: 2018, VFR 2019 and the same IEC/EN standards, without EN 50549-10 or the NF EN entries. The manual's list is recorded as the higher-priority document.
Compliance row as printed in Hoymiles' Europe user manual (REV1.1), one cell shared by all 5 models: "EN 50549-1:2019, EN 50549-10:2022, VDE-AR-N 4105: 2018, NF EN 50549-1:2019, NF EN 50549-10:2022, IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 61000-3-2/-3". Manufacturer claims; no certificate or listing directory was checked.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Features, Compliance, one cell shared by all models
Sources
EN 50549-1: 2019; VDE-AR-N 4105: 2018; VFR 2019; IEC/EN 62109-1/-2; IEC/EN 61000-6-1/-2/-3/-4; IEC/EN 61000-3-2/-3

Printed as "EN 50549-1: 2019, VDE-AR-N 4105: 2018, VFR 2019, IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 61000-3-2/-3" in Hoymiles' Europe data sheet (V202408). Manufacturer claims.

[2]
[1]
Max PV input current12 A
Printed as "2 × 12" in the HMS-600-2T column of the row "Maximum input current (A) 2 × 12 2 × 13 2 × 14 2 × 15 2 × 16": 2 inputs at 12 A each; the per-input figure is recorded. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Input Data (DC), Maximum input current (A), HMS-600-2T column (first of 5)
[1] [2]
Max PV short circuit20 A
Printed as "2 × 20" in the HMS-600-2T column of the row "Maximum input short circuit current (A) 2 × 20 2 × 20 2 × 25 2 × 25 2 × 25": 2 inputs at 20 A each; the per-input figure is recorded. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Input Data (DC), Maximum input short circuit current (A), HMS-600-2T column (first of 5)
[1] [2]
Operating temperature-40 to 65 °C / -40 to 149 °F converted
Printed as "Ambient temperature range (℃) -40 to +65", one cell shared by all 5 models. Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Mechanical Data, Ambient temperature range, one cell shared by all models
[1] [2]
AC voltage configuration230 V nominal (180 to 275 V range), 50 Hz nominal (45 to 55 Hz range)
Printed as nominal output voltage/range 230/180 to 275 V and nominal frequency/range 50/45 to 55 Hz (ranges written with "to"), one cell each shared by all 5 models; single-phase. The footnote reads "Nominal voltage/frequency range can vary depending on local requirements." Hoymiles' Europe data sheet (V202408) prints the same value.
Where: Hoymiles' Europe user manual (REV1.1), PDF page 34 (printed page 30), section 8 Technical Data, Output Data (AC), nominal output voltage and frequency, one cell shared by all models
[1] [2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

AC output (VA)
600 VA
Battery voltage
Not stated
Solar input
Not statedMPPT trackers 2MPPT range 16 to 60 V
AC output
Not stated
Warranty
Not stated
Size
1.65 L* (Calculated from published dimensions)W: 261 × H: 180 × D: 35.1 mm / W: 10.3 × H: 7.09 × D: 1.38 inWeight 3.2 kg / 7.1 lb

Evidence score

Research pending0% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Hoymiles User Manual, Single-phase Microinverter HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T, Region: Europe, REV1.1Official · Hoymiles · Official user manual · PDF
    Source details
    Revision
    REV1.1
    Revision date
    Not stated

    Archived copy captured from www.hoymiles.com on October 10, 2026 at 05:14:31 UTC, obtained by Alternative Research from the file linked on Hoymiles' download page https://www.hoymiles.com/downloads/user-manual-guide-hms-600-amp-700-amp-800-amp-900-amp-1000-2t-eu-en.html. The copy read hashes to the SHA-256 recorded for this source.

    Retrieved Oct 9, 2026

    Hoymiles' own user manual for the HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T microinverters, cover printed "USER MANUAL Region: Europe REV1.1". Read in full; its section 8 Technical Data table (PDF page 34, printed page 30, one column per model) was also checked on the rendered page and is the primary source for these models. Hoymiles links this file from its own download page https://www.hoymiles.com/downloads/user-manual-guide-hms-600-amp-700-amp-800-amp-900-amp-1000-2t-eu-en.html (the page's file link is https://w3oss.hoymiles.com/uploadfile/1/202509/b0bc03055e.pdf); the same file is served openly at https://www.hoymiles.com/uploadfile/1/202509/b0bc03055e.pdf, the address this copy was taken from. Manufacturer claims, not an independent test.

    Archived copies

    Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupREV1.1 · 16.22 MB

    Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://www.hoymiles.com/uploadfile/1/202509/b0bc03055e.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    38

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 3ef60ea81b622f63e93245423ea872c87524ecfbb1cda4ba8575d939e85c73f7

    Open
  • Datasheets

  • Hoymiles Microinverter Datasheet, HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T, Region: Europe, V202408Official · Hoymiles · Official datasheet · PDF
    Source details
    Revision
    V202408
    Revision date
    Not stated

    Archived copy captured from www.hoymiles.com on October 10, 2026 at 04:02:50 UTC, obtained by Alternative Research from the file linked on Hoymiles' download page https://www.hoymiles.com/downloads/datasheet-hms-600-amp-700-amp-800-amp-900-amp-1000-2t-eu-en.html. The copy read hashes to the SHA-256 recorded for this source.

    Retrieved Oct 9, 2026

    Hoymiles' own two-page data sheet for the HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T microinverters, printed "Region: Europe V202408" with the copyright line "© 2025 Hoymiles Power Electronics Inc.". Read in full; its Technical Specifications table (PDF page 2) was also checked on the rendered page. It is the second source for these models, after the European user manual. Hoymiles links this file from its own download page https://www.hoymiles.com/downloads/datasheet-hms-600-amp-700-amp-800-amp-900-amp-1000-2t-eu-en.html (the page's file link is https://w3oss.hoymiles.com/uploadfile/1/202506/3e58c1d079.pdf); the same file is served openly at https://www.hoymiles.com/uploadfile/1/202506/3e58c1d079.pdf, the address this copy was taken from. Manufacturer claims, not an independent test.

    Archived copies

    Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupV202408 · 0.59 MB

    Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://www.hoymiles.com/uploadfile/1/202506/3e58c1d079.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    2

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: e27f602e3f39b030e5656c67a6a293508f2f9ae8b0e495d327e53ceb4e85a9ee

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Hoymiles User Manual, Single-phase Microinverter HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T, Region: Europe, REV1.1

Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupREV1.1 · 16.22 MB

Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://www.hoymiles.com/uploadfile/1/202509/b0bc03055e.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
38

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 3ef60ea81b622f63e93245423ea872c87524ecfbb1cda4ba8575d939e85c73f7

Hoymiles Microinverter Datasheet, HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T, Region: Europe, V202408

Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupV202408 · 0.59 MB

Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://www.hoymiles.com/uploadfile/1/202506/3e58c1d079.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
2

Embedded dates are file metadata, not independent proof of publication.

SHA-256: e27f602e3f39b030e5656c67a6a293508f2f9ae8b0e495d327e53ceb4e85a9ee

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
HMS-600-2T

Manufacturer SKU HMS-600-2T · EU market

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 0
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Hoymiles User Manual, Single-phase Microinverter HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T, Region: Europe, REV1.1 (Hoymiles · manufacturer · REV1.1 · observed Oct 9, 2026)
  2. Hoymiles Microinverter Datasheet, HMS-600-2T, HMS-700-2T, HMS-800-2T, HMS-900-2T and HMS-1000-2T, Region: Europe, V202408 (Hoymiles · manufacturer · V202408 · observed Oct 9, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details