Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Photo sources
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Maker series photo: Hoymiles HM-600NT: Hoymiles' family image from the cover of Hoymiles' North America datasheet for the HM-600NT, HM-700NT and HM-800NT, which names this model; the same image stands for every model the document covers. A front view of the silver microinverter with its DC leads on both sides and its AC cable, on a light background; the page heading is left out. Figure from the manufacturer's document, page 1.Microinverter
Hoymiles HM-600NT Microinverter
Key specs
All specifications
Identity
SKU detail
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 2.6 kg / 5.7 lb converted | Printed once for all three models as 5.73 lbs (2.6 kg). Where: Page 2, Mechanical Data, Weight | [1] |
| MPPT count | 2 | Two MPPTs with one input each, printed once for all three models. Where: Page 2, Input Data (DC), Number of MPPTs | [1] |
| Peak output | 600 VA (peak output power) | Printed as 600 VA in the HM-600NT column (first of 600, 700, 800). No duration is printed. Where: Page 2, Output Data (AC), Peak output power (VA), HM-600NT column (first of three) | [1] |
| Dimensions | W 250 × H 170 × D 28 mm / W 9.84 × H 6.69 × D 1.1 in converted | Printed once for all three models as 9.84 × 6.69 × 1.10 in (250 × 170 × 28 mm), width by height by depth. Where: Page 2, Mechanical Data, Dimensions (W × H × D) | [1] |
| Communications | 2.4 GHz Proprietary RF (Nordic) | Communication with the Hoymiles DTU gateway as printed, once for all models; monitoring through S-Miles Cloud. Where: Page 2, Features, Communication | [1] |
| Efficiency | 96.7 % | CEC peak efficiency, printed once for all models. Manufacturer claim. Where: Page 2, Efficiency, CEC peak efficiency | [1] |
| MPPT voltage | 16 to 60 V | Printed once for all models as 16-60 V; start-up voltage 22 V. Where: Page 2, Input Data (DC), MPPT voltage range (V) | [1] |
| Enclosure rating | Outdoor, NEMA 6 (IP67) | Printed as "Outdoor-NEMA 6 (IP67)", once for all models. Where: Page 2, Mechanical Data, Enclosure rating | [1] |
| Max PV voltage | 60 V | Printed once for all three models. Where: Page 2, Input Data (DC), Maximum input voltage (V) | [1] |
| Apparent power | 590 VA | Printed as 590 VA in the HM-600NT column (first of 590, 696, 766). Printed in volt-amperes; no W rating is printed. Peak output power is 600 VA. Where: Page 2, Output Data (AC), Maximum continuous output power (VA), HM-600NT column (first of three) | [1] |
| PV start voltage | 22 V | Printed once for all models. Where: Page 2, Input Data (DC), Start-up voltage (V) | [1] |
| Certification claims | UL 1741; IEEE 1547; UL 1741 SA (240 Vac); UL 1741 SB; CA Rule 21 (240 Vac); CSA C22.2 No. 107.1-16; FCC Part 15B; FCC Part 15C | Compliance row as printed by Hoymiles, one row for all models; footnote 4 says only the HM-800NT also complies with CA Rule 21 (208 Vac). Manufacturer claim; no issuer directory was checked. Where: Page 2, Features, Compliance | [1] |
| Max PV input current | 11.5 A | Printed as 2 × 11.5 A for the HM-600NT (first column): 11.5 A per MPPT. Maximum input short circuit current 2 × 15 A, printed once for all models. Where: Page 2, Input Data (DC), Maximum input current (A), HM-600NT column (first of three) | [1] |
| Operating temperature | -40 to 65 °C / -40 to 149 °F converted | Ambient temperature range printed once for all models as -40 to +149 °F (-40 to +65 °C). Where: Page 2, Mechanical Data, Ambient temperature range | [1] |
| Weighted efficiency | 96.5 % | CEC weighted efficiency, printed once for all models. Manufacturer claim. Where: Page 2, Efficiency, CEC weighted efficiency | [1] |
| AC voltage configuration | 240 V (211-264 V) or 208 V (183-228 V), 60 Hz | Nominal output voltage and range printed for the HM-600NT (first of three) column as 240/211-264 and 208/183-228, nominal frequency 60/55-65 Hz printed once for all models. Hoymiles notes the range can vary with local requirements. Where: Page 2, Output Data (AC), Nominal output voltage/range and Nominal frequency/range | [1] |
Owner reviews
Write a reviewSellers
No listed sellers in this data.
Price history
No seller price history.
Quick reference sheet
- AC output (VA)
- 590 VA
- Battery voltage
- Not stated
- Solar input
- Not statedMPPT trackers 2MPPT range 16 to 60 V
- AC output
- Not stated
- Warranty
- Not stated
- Size
- 1.19 L* (Calculated from published dimensions)W: 250 × H: 170 × D: 28 mm / W: 9.84 × H: 6.69 × D: 1.1 inWeight 2.6 kg / 5.7 lb
Evidence score
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Research pending, 0 points: Warranty term, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
How it worksCertificates
CECauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- HM-600NT
- Limitations
- Model HM-600NT listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) under Hoymiles Power Electronics Inc., as "HM-600NT {240V}", grid support listing date 2020-05-11. This is an equipment listing, not UL certification or complete-system approval.
- Record detail
- Issued: Not statedValid from: May 11, 2020Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
UL 1741 SAauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- HM-600NT
- Limitations
- Listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) as Hoymiles Power Electronics Inc. "HM-600NT {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2020-04-03. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Apr 3, 2020Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
UL 1741 SBauthority listing reportedlisted as of snapshot[2]
- Scope
- equipment listing
- Covered models
- HM-600NT
- Limitations
- Listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) as Hoymiles Power Electronics Inc. "HM-600NT {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2023-03-15. A state equipment list entry, not the certification body's own record.
- Record detail
- Issued: Not statedValid from: Mar 15, 2023Expiry: Not statedIssuer checked: Oct 11, 2026
- Source
- [2]
Warranty
Unknown: no warranty facts recorded.
Recalls / legal notices
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Documents
Datasheets
- Hoymiles Microinverter Datasheet HM-600NT, HM-700NT, HM-800NT, Region: North America, REV1.3Open
Source details
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-24.
Location: Page 2, Technical Specifications
Retrieved Sep 23, 2026
Hoymiles' own two-page North America datasheet for the HM-600NT, HM-700NT and HM-800NT, reached from the Datasheet link on the product page (downloads/datasheet-hm-600nt-amp-700nt-amp-800nt-na-en.html) and captured on September 24, 2026. The table prints one column per model; rows that print two values per model give the 240 V figure first and the 208 V figure second. The Compliance row is a manufacturer claim; no issuer directory was read. The warranty row reads "Up to 25 years" without terms.
Archived copies
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived backupREV1.3 · 0.64 MBArchived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202508/8a64e9484c.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 364819b16f9e0e40e27668bd25e790c3667d2428e2bea23f835d62afc4613bf6
Archive and older revisions
Archive and older revisions0
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Hoymiles Microinverter Datasheet HM-600NT, HM-700NT, HM-800NT, Region: North America, REV1.3
Archived copy of a document published by Hoymiles. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Hoymiles published. Original address: https://w3oss.hoymiles.com/uploadfile/1/202508/8a64e9484c.pdf. Copyright and takedown
File details
Original sourceEmbedded dates are file metadata, not independent proof of publication.
SHA-256: 364819b16f9e0e40e27668bd25e790c3667d2428e2bea23f835d62afc4613bf6
Parts and accessories
No sourced accessories or replacement parts listed yet.
Model history
Model identity
- Model
- HM-600NT
Manufacturer SKU HM-600NT · US market
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model HM-600NT listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) under Hoymiles Power Electronics Inc., as "HM-600NT {240V}", grid support listing date 2020-05-11. This is an equipment listing, not UL certification or complete-system approval.
Observed Oct 11, 2026
UL 1741 SB: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) as Hoymiles Power Electronics Inc. "HM-600NT {240V}": UL 1741 SB, certifying entity CSA Group, certificate date 2023-03-15. A state equipment list entry, not the certification body's own record.
Observed Oct 11, 2026
UL 1741 SA: claimed
Product / system scope unresolved. Listed on the California Energy Commission Grid Support Inverter Lists (data unchanged since October 1, 2026; downloaded October 11, 2026) as Hoymiles Power Electronics Inc. "HM-600NT {240V}": UL 1741 SA, certifying entity CSA Group, certificate date 2020-04-03. A state equipment list entry, not the certification body's own record.
Other recorded fields
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 45 basis: Unknown missing: Warranty term needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 31.5 unit: Unknown shown: UL 1741 SB · CEC +1 shown detail: Claimed state: claimed points: 14.2 ceiling: 45 weight: 45 share: 31.5 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: Manufacturer claim; issuer verification pending. Applies to the exact inverter. display note: Unknown Sources: [2] key: warranty label: Warranty term value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 30 weight: 30 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
Community discussions
No discussions linked yet. Search DIY Solar Forum
Sources
- Hoymiles Microinverter Datasheet HM-600NT, HM-700NT, HM-800NT, Region: North America, REV1.3 (Hoymiles · manufacturer · REV1.3 · observed Sep 23, 2026)
- CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) (California Energy Commission · government equipment registry · Data unchanged since October 1, 2026 · observed Oct 10, 2026 · effective Oct 1, 2026)
Sign in to report an error on this page
Similar products
All with a priceAPsystems DS3-L
APsystems DS3-S
APsystems EZ1-LV Plug-in Microinverter
Aptos MAC-400 Microinverter
* Missing details