10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed once for all four models.
No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 63 kg / 140 lb converted | Printed as net weight 63 kg (gross 74 kg) once for all four models. Where: Page 2, General data, Weight | [1] |
| AC voltage | 120V/208V, 120V/240V split (180 to 280 Vac) | Recorded as printed. Where: Page 2, Output data (AC) | [1] |
| Max charge | 312.5 A | Printed as 312.5A. Where: Page 2, Battery data (DC), SPH 15000TL-HU-US column | [1] |
| Dimensions | W 516 × H 870 × D 308.8 mm / W 20.3 × H 34.3 × D 12.16 in converted | Printed as 516/870/308.8mm (W/H/D) once for all four models. Where: Page 2, General data, Dimensions(W/H/D) | [1] |
| Communications | WIFI/LAN; RS485/CAN/USB interfaces | As printed. Where: Page 2, General data | [1] |
| Efficiency | 98.1 % | Printed as 98.10% peak efficiency. Where: Page 2, Efficiency | [1] |
| MPPT voltage | 150V-450V/370V | Recorded as printed. Where: Page 2, Input data (DC) | [1] |
| Solar array | 30 kW | Printed as 30000W, the maximum recommended PV power for module STC. Where: Page 2, Input data (DC), SPH 15000TL-HU-US column | [1] |
| AC frequency | 60 Hz | Printed as 60Hz. Where: Page 2, Backup power (AC) | [1] |
| Max discharge | 312.5 A | Printed as 312.5A. Where: Page 2, Battery data (DC), SPH 15000TL-HU-US column | [1] |
| Backup output | 15 kW | Printed as 15000W. Where: Page 2, Backup power (AC), SPH 15000TL-HU-US column | [1] |
| Enclosure rating | IP65 | As printed. Where: Page 2, General data | [1] |
| Max PV current | 40 A | Printed as 40A per MPP tracker. Where: Page 2, Input data (DC) | [1] |
| Max PV voltage | 550 V | Printed once for all four models. Where: Page 2, Input data (DC) | [1] |
| Transfer time | 10 ms | Printed as less than 10ms. Where: Page 2, Backup power (AC) | [1] |
| Apparent power | 15,000 VA | Printed as 15000VA. Where: Page 2, Output data (AC), SPH 15000TL-HU-US column | [1] |
| Grid passthrough | 200 A | Printed once for all four models. Where: Page 2, AC input data (AC) | [1] |
| PV start voltage | 100 V | Printed once for all four models. Where: Page 2, Input data (DC) | [1] |
| Certification claims | IEEE1547, CA RULE21, RULE14(HECO Compliant), UL1741, UL1741SA/SB, CSA C22.2, CSA C22.3 PREPA, UL1699B, UL3141, FCC Part15 Class B, Sunspec | Printed once for all four models. Where: Page 2, Compliance row | [1] |
| Continuous output | 15 kW | Printed as 15000W. Where: Page 2, Output data (AC), AC nominal power, SPH 15000TL-HU-US column | [1] |
| Max PV short circuit | 50 A | Printed as 50A per MPP tracker. Where: Page 2, Input data (DC) | [1] |
| Battery voltage range | 40 to 60 V | Printed as 40~60V. Where: Page 2, Battery data (DC) | [1] |
| Operating temperature | -25 to 60 °C / -13 to 140 °F converted | Printed as -25~60°C, derating above 45°C. Where: Page 2, General data | [1] |
| Weighted efficiency | 97 % | Printed as 97.00% CEC efficiency. Where: Page 2, Efficiency | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed once for all four models.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 10 years | Printed once for all four models. Where: Page 2, General data | [1] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Datasheet; captured Nov 3, 2026.
Location: Page 2, datasheet table
Retrieved Nov 3, 2026
Growatt's own datasheet from its US site, captured with the paced research fetcher; an image-only PDF, its pages rendered and read.
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPH_9600-18000TL-HU-US_datasheet_202610.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 2ec56f9a8b222879ea7a26ba1aaf28e24f3c141c81e10822646d356fc18bed14
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPH_9600-18000TL-HU-US_datasheet_202610.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 2ec56f9a8b222879ea7a26ba1aaf28e24f3c141c81e10822646d356fc18bed14
No sourced accessories or replacement parts listed yet.
US market
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 10 unit: Unknown shown: 10 years shown detail: Unknown state: documented points: 12 ceiling: 30 weight: 30 share: 40 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.