2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 2 Years" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Warranty, captured on September 26, 2026.
Manufacturer and seller images. Configuration examples may include additional equipment.
Image source: Maker series photo: Growatt SPF 12000T DVM-US, the product photo on the cover of Growatt's SPF 4000T~12000T DVM-US datasheet (EN, 202212), a series datasheet whose specification table names the SPF 12000T DVM-US. Cropped to the unit; the cover's scene and headings are left out. Figure from the manufacturer's document, page 1.No spec by that name.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Weight | 75 kg / 170 lb converted | Printed as "75kg(165.3lb)" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Weight, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). Where: Datasheet table, Weight | [1] |
| MPPT count | 2 | Printed as "1/1 2/1" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Number of independent MPP trackers/ strings per MPP tracker, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). Where: Datasheet table, Number of independent MPP trackers/ strings per MPP tracker | [1] |
| Peak output | 36 kW (surge rating) | Printed as "8KW 10KW 12KW 24KW 30KW 36KW" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Surge Rating, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). No surge duration is printed. Where: Datasheet table, Surge Rating | [1] |
| AC voltage | 104-110-115-120/208-220-230-240VAC (optional) | Printed as "Nominal Output Voltage RMS 104-110-115-120/208-220-230-240VAC(optional)" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Inverter Output, captured on September 26, 2026. Where: Datasheet table, Inverter Output | [1] |
| Max charge | 100 A | Printed as "70A 80A 100A" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Max. Charging Current, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). Where: Datasheet table, Max. Charging Current | [1] |
| Dimensions | W 380 × H 650 × D 225 mm / W 15 × H 25.6 × D 8.86 in converted | Printed as "380/650/225mm (15/25.6/8.6in)" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Dimensions (W/H/D), captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). Where: Datasheet table, Dimensions (W/H/D) | [1] |
| Communications | RS485; CAN | Printed as "You can choose RS485 communication protocol which is from L01 to L50, and you can also choose CAN communication protocol which is from L51 to L99. Note: You can only use one communication type RS485 or CAN in a time." in the Growatt SPF Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0, image-only document, read from the rendered pages), captured September 27, 2026. BMS communication via RJ45; separate PC monitoring uses a supplied communication cable and software from www.ginverter.com (Communication Connection section, PDF page 4, printed page 11). Where: PDF page 3 (printed pages 6-7), Lithium battery communication and setting | [2] |
| Efficiency | 85 % greater than 85% (peak) | Printed as "Inverter Efficiency(Peak) Transfer Time >85% 10ms(max)" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Inverter Efficiency(Peak), captured on September 26, 2026. Printed as greater than 85% peak inverter efficiency; the separate Maximum Efficiency row is the solar charger figure and is not recorded here. Where: Datasheet table, Inverter Efficiency(Peak) | [1] |
| MPPT voltage | 60 to 145 V | Printed as "120A 60~145VDC 7000W" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, MPPT Range @ Operating Voltage, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). Where: Datasheet table, MPPT Range @ Operating Voltage | [1] |
| Solar array | 7 kWConverted: 7000W x 0.001 | Printed as "48V 5000W 7000W 60-145V 150VDC" in Growatt Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0), User manual, Specifications (PDF page 16, printed page 29), Solar Charger, Maximum PV Array Power row (7000W cell covering the SPF 12000T DVM-US column). Revised on 1 October 2026: Growatt's user manual prints the maximum PV array power in watts for this model, and the kilowatt figure is a direct conversion; the manual is the primary source. Where: User manual, Specifications (PDF page 16, printed page 29), Solar Charger, Maximum PV Array Power row (7000W cell covering the SPF 12000T DVM-US column) SourcesConverted: 7000W x 0.001 | [2] |
| AC frequency | 50Hz/60Hz (±0.3 Hz) | Printed as "Output Frequency 50Hz/60Hz ( +/-0.3 Hz )" in the Growatt SPF Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0, image-only document, read from the rendered pages), Specifications table, captured September 27, 2026. Same for every DVM-US model. Where: PDF page 16 (printed page 29), Specifications, INVERTER OUTPUT, Output Frequency row | [2] |
| Max PV charge | 120 A | Printed as "120A 60~145VDC 7000W" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Solar Charger, Maximum PV Charge Current, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). Where: Datasheet table, Solar Charger, Maximum PV Charge Current | [1] |
| Output waveform | Pure sine wave | Printed as "Waveform Pure sine wave/ same as input (bypass mode)" in Growatt's SPF DVM-US datasheet; in bypass mode the output follows the AC input. Where: Datasheet page 2, INVERTER OUTPUT, Waveform row (one value across the SPF 4000T to 12000T DVM-US columns); spec-table row | [1] |
| AC configuration | 120/240Vac Split Phase output | Printed as "120/240Vac Split Phase output" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet page 1, feature list, captured on September 26, 2026. Where: Datasheet page 1, feature list | [1] |
| Enclosure rating | IP20/NEMA Type 1 | Printed as "IP20/NEMA Type 1" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Protection Degree, captured on September 26, 2026. Where: Datasheet table, Protection Degree | [1] |
| Max PV current | 120 A | Printed as "Typical Amperage 80A" (4KW/5KW/6KW) or "120A" (8KW/10KW/12KW) in the Growatt SPF Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0, image-only document, read from the rendered pages), PV Connection cable-sizing table, captured September 27, 2026. Matches the Specifications table's "Maximum PV Charge Current" row (80A / 120A) for the same model groups. Where: PDF page 4 (printed page 10), PV Connection, Typical Amperage row | [2] |
| Max PV voltage | 150 V | Printed as "150VDC >98%" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Maximum PV Array Open Circuit Voltage, captured on September 26, 2026. Where: Datasheet table, Maximum PV Array Open Circuit Voltage | [1] |
| Surge duration s | 0.02 s | Printed as "Surge Rating (20ms)" in Growatt Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0), User manual, Specifications (PDF page 16, printed page 29), Inverter Output, Surge Rating (20ms) row. Revised on 1 October 2026: Growatt's user manual prints the surge duration as 20ms, and the stored 0.02 s is a direct conversion of that printed figure. Where: User manual, Specifications (PDF page 16, printed page 29), Inverter Output, Surge Rating (20ms) row SourcesConverted: 20 ms x 0.001 = 0.02 s | [2] |
| Transfer time | 10 ms | Printed as ">85% 10ms(max)" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Transfer Time, captured on September 26, 2026. Printed as a maximum. Where: Datasheet table, Transfer Time | [1] |
| Battery output | 12 kW | Printed as "Rated Power 4KW 5KW 6KW 8KW 10KW 12KW" in the Growatt SPF Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0, image-only document, read from the rendered pages), Specifications table, SPF 12000T DVM-US column, captured September 27, 2026. This off-grid inverter's rated AC output is delivered from the battery/PV DC bus; no separate battery-only output figure is printed. Where: PDF page 16 (printed page 29), Specifications, INVERTER OUTPUT, Rated Power row, SPF 12000T DVM-US column | [2] |
| Battery wire size | 90 mm2 (0-1.0 m run), 120 mm2 (1.0-5.0 m run) | Printed in the "Recommended battery cable and terminal size" table in the Growatt SPF Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0, image-only document, read from the rendered pages): 12kw, 48V, Wire Gage/min 0~1.0m = 90 mm2, Wire Gage/min 1.0~5.0m = 120 mm2, captured September 27, 2026. Where: PDF page 3 (printed page 5), Battery Connection, Recommended battery cable and terminal size, SPF 12000T row | [2] |
| Nominal voltage | 48 V | Printed as "Lithium/Lead-acid 48VDC" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Battery Voltage, captured on September 26, 2026. Where: Datasheet table, Battery Voltage | [1] |
| Continuous output | 12 kW | Printed as "8KW 10KW 12KW 24KW 30KW 36KW" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Rated Power, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-US column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). Where: Datasheet table, Rated Power | [1] |
| Battery compatibility | AGM (default), flooded lead-acid, or user-defined lead-acid profiles (program 5); lithium only with BMS communication over RS485 (protocols L01-L50) or CAN (L51-L99). Recommended minimum capacity: 200Ah for the 4-6kW models, 400Ah for the 8-12kW models. | Printed as "AGM (Default)", "Flood", "User-Defined", "User-Defined 2", "Lithium (Only suitable when communicate with BMS)" (LCD setting, Program 05, Battery type) and "It's suggested to connect at least 200Ah capacity battery for 4KW~6KW model and at least 400Ah capacity battery for 8KW~12KW model" (Battery Connection) in the Growatt SPF Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (Version 1.0, image-only document, read from the rendered pages), captured September 27, 2026. Where: PDF pages 3-5 (printed pages 5-7), Battery Connection; Lithium battery communication and setting | [2] |
| Operating temperature | 0 to 50 °C / 32 to 122 °F converted | Printed as "0°C 50°C 32 122- ( °F- °F)" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Operation Temperature Range, captured on September 26, 2026. The text layer splits the printed range "0°C - 50°C (32°F - 122°F)" into these runs. Where: Datasheet table, Operation Temperature Range | [1] |
| Other compliance claims | UL 1741 | Printed as "UL 1741" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, certification row, captured on September 26, 2026. A manufacturer claim; no issuer record was read. Where: Datasheet table, certification row | [1] |
No listed sellers in this data.
No seller price history.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty 2 Years" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Warranty, captured on September 26, 2026.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
How it worksUnknown: no certification evidence recorded in this data.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Warranty term | 2 years | Printed as "Warranty 2 Years" in the Growatt SPF 4000T~12000T DVM-US datasheet (EN 202212), Datasheet table, Warranty, captured on September 26, 2026. Where: Datasheet table, Warranty | [1] |
No recalls on file. All notices · Report a notice
This register is incomplete. A missing notice does not establish that a product has no recalls.
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-27.
Location: Battery Connection; AC Input/Output Connection; PV Connection; Communication Connection; Specifications
Retrieved Sep 27, 2026
Growatt's own user manual, listed on the SPF 4000-12000T DVM-US product page (us.growatt.com), captured September 27, 2026. Image-only document with no text layer: facts were read from the rendered pages and cite the PDF page (each PDF page shows two printed pages). Its own Validity page names twelve exact models: SPF 4000/5000/6000/8000/10000/12000T DVM-US and the same six with a DVM-US MPV suffix. Only the plain DVM-US six are used in this manifest.
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM-US_MPV_User_Manual_EN_202109.pdf. Copyright and takedown
Printed revision date: 2021-09
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fbf39b6b0c56a28f8656163ad391692199e951e5d78a72e1e1f5ad53df945047
Identity at specified physical page; specifications only where separately field-cited
Location: PDF page 2
Retrieved Sep 15, 2026
SHA-256: 522f5b1f779b456b532500dd3b21776033646571a8785ac1f8485ab1680d093c
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM-US_Datasheet_EN_202212.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 522f5b1f779b456b532500dd3b21776033646571a8785ac1f8485ab1680d093c
Captured with a plain HTTPS GET and a browser user agent.
Location: SPF 4000-12000T DVM-US | Split Phase Off-Grid | Growatt
Retrieved Sep 19, 2026
Growatt's own US product page for the SPF 4000-12000T DVM-US family, captured as delivered HTML. It establishes what Growatt published on that page on the access date and nothing more: it is a family page, so it is used here only for the product photo and only for the models the page title or the photo's own caption names. No specification, rating or part number was taken from it.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM-US_Datasheet_EN_202212.pdf. Copyright and takedown
Embedded dates are file metadata, not independent proof of publication.
SHA-256: 522f5b1f779b456b532500dd3b21776033646571a8785ac1f8485ab1680d093c
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy, unaltered, kept as a record of what Growatt published. Original address: https://us.growatt.com/upload/file/SPF_4000-12000T_DVM-US_MPV_User_Manual_EN_202109.pdf. Copyright and takedown
Printed revision date: 2021-09
Embedded dates are file metadata, not independent proof of publication.
SHA-256: fbf39b6b0c56a28f8656163ad391692199e951e5d78a72e1e1f5ad53df945047
No sourced accessories or replacement parts listed yet.
1 other version recorded
No historical observations recorded yet.
| Field | Value | Conditions | Source |
|---|---|---|---|
| Evidence breakdown | method version: inverters-0.5-personal documented pct: 30 basis: Unknown missing: Certificate evidence needed Battery conversion efficiency needed Idle consumption needed criteria: key: certificates label: Certificates value: 0 unit: Unknown shown: Listing stated, none checked shown detail: Unknown state: pending points: 0 ceiling: 45 weight: 45 share: 0 covered: no missing: yes folded: yes reason: Unknown reason text: Unknown note: No qualifying inverter certificate evidence recorded. display note: Unknown Sources: No source on record key: warranty label: Warranty term value: 2 unit: Unknown shown: 2 years shown detail: Unknown state: documented points: 2.4 ceiling: 30 weight: 30 share: 8 covered: yes missing: no folded: no reason: Unknown reason text: Unknown note: display note: Unknown Sources: [1] key: efficiency label: Battery conversion efficiency value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 15 weight: 15 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record key: idle label: Idle consumption value: Unknown unit: Unknown shown: Research pending shown detail: Unknown state: pending points: 0 ceiling: 10 weight: 10 share: Unknown covered: no missing: yes folded: yes reason: undocumented reason text: Not documented. Undisclosed data scores 0. note: Not documented. display note: Unknown Sources: No source on record | ||
No discussions linked yet. Search DIY Solar Forum
Sign in to report an error on this page
* Missing details