conditions: Growatt prints no ordering SKU for this edition; the model is the datasheet column label.
Sources: No source on record
No spec by that name.
Units
Field
Value
Conditions
Source
Weight
75 kg / 170 lb converted
Printed as "380/650/225mm 64kg 66kg 75kg" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Weight, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second).
Printed as "1/1 2/1" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Number of independent MPP trackers/ strings per MPP tracker, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second).
Where: Datasheet table, Number of independent MPP trackers/ strings per MPP tracker
Printed as "8KW 10KW 12KW 24KW 30KW 36KW" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Surge Rating, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second). No surge duration is printed.
Printed as "Nominal Output Voltage RMS 104-110-115-120/208-220-230-240VAC(optional)" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Inverter Output, captured on September 26, 2026.
Printed as "70A 80A 100A" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Max. Charging Current, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second).
W 380 × H 650 × D 225 mm / W 15 × H 25.6 × D 8.86 in converted
Printed as "380/650/225mm" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Dimensions (W/H/D), captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second).
Printed as "You can choose RS485 c ommunication protocol which is from L01 to L50, and you can also choose CAN communication protocol which is from L51 to L99. Note: You can only use one communication type RS485 or CAN in a tim" in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), captured September 27, 2026. BMS communication via RS485 or CAN, one at a time; written once for the whole manual, not split by DVM/DVM-MPV.
Where: Manual, 2. LCD setting, Program 51 (communication protocol)
Printed as "Inverter Efficiency(Peak) Transfer Time >85% 10ms(max)" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Inverter Efficiency(Peak), captured on September 26, 2026. Printed as greater than 85% peak inverter efficiency; the separate Maximum Efficiency row is the solar charger figure and is not recorded here.
Printed as "120A 60~245VDC 7000W" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, MPPT Range @ Operating Voltage, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second).
Where: Datasheet table, MPPT Range @ Operating Voltage
Printed as "Maximum PV Array Power 5000W 7000W" in Growatt datasheet, Datasheet page 2, Solar Charger, Maximum PV Array Power row (7000W cell spanning SPF8000T to SPF12000T DVM-MPV). Revised on 1 October 2026: Growatt prints the maximum PV array power in watts for this model, and the kilowatt figure is a direct conversion of that printed value.
Where: Datasheet page 2, Solar Charger, Maximum PV Array Power row (7000W cell spanning SPF8000T to SPF12000T DVM-MPV)
Printed as "120A 60~245VDC 7000W" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Solar Charger, Maximum PV Charge Current, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second).
Where: Datasheet table, Solar Charger, Maximum PV Charge Current
Printed as "120/240Vac Split Phase output" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet page 1, feature list, captured on September 26, 2026.
Printed as "Protection Degree IP20" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Protection Degree, captured on September 26, 2026.
Printed as "Model Typical Amperage Cable Size Torque 4KW/5KW/6KW 80A 8AWG 1.6~1.8 Nm 8KW/10KW/12KW 120A 8AWG 1.6~1.8 Nm" in the Growatt SPF 4000-12000T DVM/DVM-MPV User Manual (202212), captured September 27, 2026. Tabulated by kW rating only, not split by DVM/DVM-MPV.
Printed as "250VDC >97.5%" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Maximum PV Array Open Circuit Voltage, captured on September 26, 2026.
Where: Datasheet table, Maximum PV Array Open Circuit Voltage
Printed as ">85% 10ms(max)" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Transfer Time, captured on September 26, 2026. Printed as a maximum.
Printed as "Lithium/Lead-acid 48VDC" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Battery Voltage, captured on September 26, 2026.
Printed as "8KW 10KW 12KW 24KW 30KW 36KW" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Rated Power, captured on September 26, 2026. The datasheet prints its six-column table with labels and values in separate runs; values are matched to the SPF 12000T DVM-MPV column by printed order (4000, 5000, 6000 in the first block; 8000, 10000, 12000 in the second).
05 Battery type AGM (Default); Flood; User-Defined; User-Defined 2 (Suitable for lithium battery when no communicating with BMS); Lithium (Only suitable when communicate with BMS); It‟s suggested to connect at least 200Ah capacity battery for 4KW~6KW model and at least 400Ah capacity battery for 8KW~12KW model.
Printed as "05 Battery type AGM (Default)"; "Flood"; "User-Defined"; "User-Defined 2 (Suitable for lithium battery when no communicating with BMS)"; "Lithium (Only suitable when communicate with BMS)"; "It‟s suggested to connect at least 200Ah capacity battery for 4KW~6KW model and at least 400Ah capacity battery for 8KW~12KW model." in Growatt Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (SPF DVM / DVM-MPV, EN, 202212), User manual, 2. LCD setting, program 05 Battery type; Battery Connection step 2. Revised on 1 October 2026: The manual lists a "User-Defined 2" setting for lithium batteries without BMS communication, so the record's "lithium only with BMS communication" is not what it prints.
Where: User manual, 2. LCD setting, program 05 Battery type; Battery Connection step 2
Printed as "Operation Temperature Range 0°C to 45°C" in the Growatt SPF 4000~12000T DVM-MPV datasheet (EN 202212), Datasheet table, Operation Temperature Range, captured on September 26, 2026.
Where: Datasheet table, Operation Temperature Range
55.58 L* (Calculated from published dimensions)W: 380 × H: 650 × D: 225 mm / W: 15 × H: 25.6 × D: 8.86 inWeight75 kg / 170 lb
Evidence score
Research pending0% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
Growatt's own user manual, listed on the SPF 4000-12000T DVM product page (us.growatt.com), captured September 27, 2026. Its own Validity page names twelve exact models: SPF 4000/5000/6000/8000/10000/12000T DVM and the same six with a DVM-MPV suffix. Only the plain DVM six are used in this manifest; the DVM-MPV six are not, since the manual's own Specifications table only lists columns for the DVM six.
Archived copies
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Growatt datasheet
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Growatt Off Grid Solar Inverter Split Phase 4KW-12KW User Manual (SPF DVM / DVM-MPV, EN, 202212)
Archived copy of a document published by Growatt. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].