AC output
- Continuous output
- 9.999 kW [1]
- Peak output
- 10.0 kVA, 20.0 kVA for 10 s (back-up output) [1]
- AC configuration
- ?
- AC output voltage
- 220/230/240 V, L/N/PE [1]
- AC frequency
- 50 / 60 Hz [1]
- Grid pass-through
- ?
- Maximum output per leg
- ?
Battery
- Battery voltage range
- 350 to 550 V [1]
- Maximum charge current
- 35.6 A [1]
- Maximum discharge current
- 29 A [1]
- Battery-only output
- 11 kW [1]
- Maximum grid charging
- ?
- Compatible batteries / BMS
- ?
PV input
- PV array limit (connected)
- ?
- Maximum PV voltage (Voc)
- 600 V [1]
- MPPT voltage range
- 40 to 560 V [1]
- String inputs per MPPT
- 1 / 1 / 1 / 1 [1]
- PV current per MPPT
- 20 A [1]
- PV short-circuit current
- 26 A [1]
- PV startup voltage
- 50 V [1]
Efficiency and modes
- Peak efficiency
- 97.5 % [1]
- CEC weighted efficiency
- 96.8 % [1]
- Battery conversion efficiency
- 97.8 % [1]
- Grid / off-grid modes
- ?
- Generator input
- ?
- Transfer time
- ?
- Idle consumption
- ?
- Night consumption
- 10 W [1]
- Parallel units
- ?
Communication and environment
- Communications
- ?
- Operating temperature
- -35 to 60 °C / -31 to 140 °F converted [1]
- Operating noise
- ?
Mechanical
- Dimensions
- W 800 × H 300 × D 270 mm / W 31.5 × H 11.8 × D 10.6 in converted [1]
- Weight
- 26 kg / 57 lb converted [1]
Installation (from the manual)
Clearances and orientation
- Installation clearances
- ?
- Mounting orientation
- Wall/Floor Mounted [1]
Not in the manual: Torque, Conductors, Protection, Grounding, Communication