Key specs

Weight26 kg / 57 lb converted
Continuous output9.999 kW
Max PV voltage600 V
Efficiency97.5 %
Max charge35.6 A
MPPT count4

All specifications

Identity

BrandGoodWe · Website
ModelGW9.999K-EHA-G20
MarketUnknown
Manufacturer SKUUnknown
SKU detail
conditions: GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28) prints the model code GW9.999K-EHA-G20 and no separate ordering SKU.
Sources: No source on record
FieldValueConditionsSource
Weight26 kg / 57 lb converted
Printed as "26" in the GW9.999K-EHA-G20 column of the Weight (kg) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer.
Where: User manual PDF page 284 (printed page 283), 10.1 Inverter Parameters, General Data section, Weight (kg) row, GW9.999K-EHA-G20 column
[1]
MPPT count4
Printed as "4" in the GW9.999K-EHA-G20 column of the Number of MPPTs row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 278 (printed page 277); read from the rendered page and checked against the text layer.
Where: User manual PDF page 278 (printed page 277), 10.1 Inverter Parameters, PV Side section, Number of MPPTs row, GW9.999K-EHA-G20 column
[1]
Peak output10.0 kVA, 20.0 kVA for 10 s (back-up output)
Printed as "10.0(20.0, 10s)" in the GW9.999K-EHA-G20 column of the Max. Output Apparent Power (kVA) row (Back-up Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer. Back-up port maximum apparent power (kVA); the first figure is the continuous one and the bracket gives the 10-second figure.
Where: User manual PDF page 281 (printed page 280), 10.1 Inverter Parameters, Back-up Side section, Max. Output Apparent Power (kVA) row, GW9.999K-EHA-G20 column
[1]
AC voltage220/230/240 V, L/N/PE
Printed as "220/230/240 , L/N/PE" in the GW9.999K-EHA-G20 column of the Nominal Voltage (V) row (AC Side (On-grid)) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 279 (printed page 278); read from the rendered page and checked against the text layer.
Where: User manual PDF page 279 (printed page 278), 10.1 Inverter Parameters, AC Side (On-grid) section, Nominal Voltage (V) row, GW9.999K-EHA-G20 column
[1]
Max charge35.6 A
Printed as "35.6" in the GW9.999K-EHA-G20 column of the Max. Continuous Charging Current (A) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, Battery Side section, Max. Continuous Charging Current (A) row, GW9.999K-EHA-G20 column
[1]
DimensionsW 800 × H 300 × D 270 mm / W 31.5 × H 11.8 × D 10.6 in converted
Printed as "800*300*270" in the GW9.999K-EHA-G20 column of the Dimension (W×H×D mm) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer. The row is headed W×H×D.
Where: User manual PDF page 284 (printed page 283), 10.1 Inverter Parameters, General Data section, Dimension (W×H×D mm) row, GW9.999K-EHA-G20 column
[1]
Efficiency97.5 %
Printed as "97.5%" in the GW9.999K-EHA-G20 column of the Max. Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 282 (printed page 281); read from the rendered page and checked against the text layer.
Where: User manual PDF page 282 (printed page 281), 10.1 Inverter Parameters, Efficiency section, Max. Efficiency row, GW9.999K-EHA-G20 column
[1]
MPPT voltage40 to 560 V
Printed as "40~560" in the GW9.999K-EHA-G20 column of the MPPT Operating Voltage Range (V) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 278 (printed page 277); read from the rendered page and checked against the text layer.
Where: User manual PDF page 278 (printed page 277), 10.1 Inverter Parameters, PV Side section, MPPT Operating Voltage Range (V) row, GW9.999K-EHA-G20 column
[1]
Solar input20 kW
Printed as "20" in the GW9.999K-EHA-G20 column of the Max. Input Power (kW) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, PV Side section, Max. Input Power (kW) row, GW9.999K-EHA-G20 column
[1]
AC frequency50 / 60 Hz
Printed as "50/60" in the GW9.999K-EHA-G20 column of the Nominal Frequency (Hz) row (AC Side (On-grid)) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 279 (printed page 278); read from the rendered page and checked against the text layer.
Where: User manual PDF page 279 (printed page 278), 10.1 Inverter Parameters, AC Side (On-grid) section, Nominal Frequency (Hz) row, GW9.999K-EHA-G20 column
[1]
Max discharge29 A
Printed as "29" in the GW9.999K-EHA-G20 column of the Max. Continuous Discharging Current (A) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, Battery Side section, Max. Continuous Discharging Current (A) row, GW9.999K-EHA-G20 column
[1]
Enclosure ratingIP66
Printed as "IP66" in the GW9.999K-EHA-G20 column of the Ingress Protection Rating row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer.
Where: User manual PDF page 284 (printed page 283), 10.1 Inverter Parameters, General Data section, Ingress Protection Rating row, GW9.999K-EHA-G20 column
[1]
Max PV current20 A
Printed as "20" in the GW9.999K-EHA-G20 column of the Max. MPPT Current (A) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 278 (printed page 277); read from the rendered page and checked against the text layer. Printed once for the model; read as the per-MPPT figure the row label gives (Max. MPPT ...).
Where: User manual PDF page 278 (printed page 277), 10.1 Inverter Parameters, PV Side section, Max. MPPT Current (A) row, GW9.999K-EHA-G20 column
[1]
Max PV voltage600 V
Printed as "600" in the GW9.999K-EHA-G20 column of the Max. Input Voltage (V) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, PV Side section, Max. Input Voltage (V) row, GW9.999K-EHA-G20 column
[1]
Battery output11 kW
Printed as "11" in the GW9.999K-EHA-G20 column of the Max. Discharging Power (kW) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, Battery Side section, Max. Discharging Power (kW) row, GW9.999K-EHA-G20 column
[1]
Nominal voltage380 V
Printed as "380" in the GW9.999K-EHA-G20 column of the Nominal Battery Voltage (V) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, Battery Side section, Nominal Battery Voltage (V) row, GW9.999K-EHA-G20 column
[1]
PV start voltage50 V
Printed as "50" in the GW9.999K-EHA-G20 column of the Start-up Voltage (V) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 278 (printed page 277); read from the rendered page and checked against the text layer.
Where: User manual PDF page 278 (printed page 277), 10.1 Inverter Parameters, PV Side section, Start-up Voltage (V) row, GW9.999K-EHA-G20 column
[1]
Max charge power13.5 kW
Printed as "13.5" in the GW9.999K-EHA-G20 column of the Max. Charging Power (kW) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, Battery Side section, Max. Charging Power (kW) row, GW9.999K-EHA-G20 column
[1]
Night consumption10 W
Printed as "≤10" in the GW9.999K-EHA-G20 column of the Power Self-consumption at Night (W) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer. Printed with a less-than-or-equal sign ("≤10"): the figure is an upper limit, recorded as 10 W.
Where: User manual PDF page 284 (printed page 283), 10.1 Inverter Parameters, General Data section, Power Self-consumption at Night (W) row, GW9.999K-EHA-G20 column
[1]
PV strings per MPPT1 / 1 / 1 / 1
Printed as "1/1/1/1" in the GW9.999K-EHA-G20 column of the Number of Strings per MPPT row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 278 (printed page 277); read from the rendered page and checked against the text layer. One figure per MPPT, in MPPT order.
Where: User manual PDF page 278 (printed page 277), 10.1 Inverter Parameters, PV Side section, Number of Strings per MPPT row, GW9.999K-EHA-G20 column
[1]
Continuous output9.999 kW
Printed as "9.999" in the GW9.999K-EHA-G20 column of the Nominal Power (kW) row (AC Side (On-grid)) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 278 (printed page 277); read from the rendered page and checked against the text layer.
Where: User manual PDF page 278 (printed page 277), 10.1 Inverter Parameters, AC Side (On-grid) section, Nominal Power (kW) row, GW9.999K-EHA-G20 column
[1]
Mounting orientationWall/Floor Mounted
Printed as "Wall/Floor Mounted" in the GW9.999K-EHA-G20 column of the Mounting Method row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 285 (printed page 284); read from the rendered page and checked against the text layer.
Where: User manual PDF page 285 (printed page 284), 10.1 Inverter Parameters, General Data section, Mounting Method row, GW9.999K-EHA-G20 column
[1]
Battery efficiency97.8 %
Printed as "97.8%" in the GW9.999K-EHA-G20 column of the Max. Battery to AC Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 282 (printed page 281); read from the rendered page and checked against the text layer.
Where: User manual PDF page 282 (printed page 281), 10.1 Inverter Parameters, Efficiency section, Max. Battery to AC Efficiency row, GW9.999K-EHA-G20 column
[1]
Max PV short circuit26 A
Printed as "26" in the GW9.999K-EHA-G20 column of the Max. MPPT Short Circuit Current (A) row (PV Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 278 (printed page 277); read from the rendered page and checked against the text layer. Printed once for the model; read as the per-MPPT figure the row label gives (Max. MPPT ...).
Where: User manual PDF page 278 (printed page 277), 10.1 Inverter Parameters, PV Side section, Max. MPPT Short Circuit Current (A) row, GW9.999K-EHA-G20 column
[1]
Battery voltage range350 to 550 V
Printed as "350~550" in the GW9.999K-EHA-G20 column of the Battery Voltage Range (V) row (Battery Side) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 277 (printed page 276); read from the rendered page and checked against the text layer.
Where: User manual PDF page 277 (printed page 276), 10.1 Inverter Parameters, Battery Side section, Battery Voltage Range (V) row, GW9.999K-EHA-G20 column
[1]
Operating temperature-35 to 60 °C / -31 to 140 °F converted
Printed as "-35~+60 (Derating at +40)" in the GW9.999K-EHA-G20 column of the Operating Temperature Range (℃) row (General Data) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 283 (printed page 282); read from the rendered page and checked against the text layer. The manual adds "(Derating at +40)": output is reduced above 40 °C.
Where: User manual PDF page 283 (printed page 282), 10.1 Inverter Parameters, General Data section, Operating Temperature Range (℃) row, GW9.999K-EHA-G20 column
[1]
Weighted efficiency96.8 %
Printed as "96.8%" in the GW9.999K-EHA-G20 column of the European Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 282 (printed page 281); read from the rendered page and checked against the text layer.
Where: User manual PDF page 282 (printed page 281), 10.1 Inverter Parameters, Efficiency section, European Efficiency row, GW9.999K-EHA-G20 column
[1]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
10 kWBattery only 11 kW
Battery voltage
350 to 550 V
Solar input
20 kWMPPT trackers 4MPPT range 40 to 560 V
AC output
220/230/240 V, L/N/PE
Warranty
Not stated
Size
64.8 L* (Calculated from published dimensions)W: 800 × H: 300 × D: 270 mm / W: 31.5 × H: 11.8 × D: 10.6 inWeight 26 kg / 57 lb

Evidence score

15/100Missing details15% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Warranty term needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Battery conversion efficiency97.8 %14.9 / 15.0

97.8 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10

Printed as "97.8%" in the GW9.999K-EHA-G20 column of the Max. Battery to AC Efficiency row (Efficiency) of the 10.1 Inverter Parameters table in GoodWe's ESA Series 3-10kW user manual (V1.8, 2026-07-28), PDF page 282 (printed page 281); read from the rendered page and checked against the text layer.

[1]

Research pending, 0 points: Certificates, Warranty term, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

Unknown: no warranty facts recorded.

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • ESA Series 3-10kW user manual (GoodWe, V1.8, 2026-07-28)Official · GoodWe Technologies Co., Ltd. · Official user manual · July 28, 2026 · Web page
    Source details
    Revision
    V1.8
    Revision date
    July 28, 2026

    Archived copy captured on 2026-09-29.

    Location: Applicable Products; 10.2 Battery Technical Data

    Retrieved Sep 28, 2026

    GoodWe's user manual for the single-phase ESA Series, linked as "User Manual" from the ESA 3-10kW page; the link resolves to en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_ESA-3-10kW_User-Manual-EN.pdf. Captured September 29, 2026. Section 10.2 prints Battery Technical Data for the six GW...-BAT-D-G20/G21 modules. Where it differs from the later ESA 5-30kW manual (V1.5, 2026-09-04) its value is kept as an alternative. Manufacturer claims, not independently verified.

    Archived copies

    Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backupV1.8 2026-07-28 · 35.75 MB

    Archived copy, unaltered, kept as a record of what GoodWe Technologies Co., Ltd. published. Original address: https://en.goodwe.com/Skippower/downloadFileF?id=3105&mid=60. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source

    Printed revision date: 2026-07-28

    Embedded creation date
    None
    Embedded modification date
    None
    Pages
    324

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 5cd104b9e006bd3b8265d0518dabdaaec01058f44ac065544da1d00d8cb4b619

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

ESA Series 3-10kW user manual (GoodWe, V1.8, 2026-07-28)

Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backupV1.8 2026-07-28 · 35.75 MB

Archived copy, unaltered, kept as a record of what GoodWe Technologies Co., Ltd. published. Original address: https://en.goodwe.com/Skippower/downloadFileF?id=3105&mid=60. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source

Printed revision date: 2026-07-28

Embedded creation date
None
Embedded modification date
None
Pages
324

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5cd104b9e006bd3b8265d0518dabdaaec01058f44ac065544da1d00d8cb4b619

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
GW9.999K-EHA-G20

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 15
basis: Unknown
missing:
Certificate evidence needed
Warranty term needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: 97.8
unit: Unknown
shown: 97.8 %
shown detail: Unknown
state: documented
points: 14.9
ceiling: 15
weight: 15
share: 99.6
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [1]
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. ESA Series 3-10kW user manual (GoodWe, V1.8, 2026-07-28) (GoodWe Technologies Co., Ltd. · manufacturer · V1.8 2026-07-28 · observed Sep 28, 2026)