Printed as "Weight (kg) 16 16 16" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Weight row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 123, Technical Data, Weight row, GW8.5K-MS-G40 column
Printed as "Number of MPPT 3 3 3" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Number of MPPT row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 120, Technical Data, Number of MPPT row, GW8.5K-MS-G40 column
Top ≥300mm; left ≥200mm; right ≥200mm; bottom ≥500mm; front ≥300mm
The installation space drawing prints "≥300mm" above, "≥200mm" to each side, "≥500mm" below and "≥300mm" in front in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), 4.1 Installation Requirements, installation space drawing; read from rendered page 26.
Where: PDF page 26, 4.1 Installation Requirements, installation space drawing
W 493 × H 365 × D 187 mm / W 19.4 × H 14.4 × D 7.36 in converted
Printed as "Dimension W×H×D (mm) 493*365*187" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Dimension W×H×D (mm) row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Printed as "Communication RS485, WIFI, LAN, Bluetooth,4G" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Communication row, GW8.5K-MS-G40 column. The protocol row reads "Modbus-RTU (SunSpec Compliant)".
Where: PDF page 123, Technical Data, Communication row, GW8.5K-MS-G40 column
Printed as "Max. Efficiency 97.8% 97.9% 97.9%" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Max. Efficiency row, GW8.5K-MS-G40 column. The GW8.5K-MS-G40 column reads "97.9%". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Printed as "MPPT Operating Voltage Range (V) 40~560 40~560 40~560" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, MPPT Operating Voltage Range row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 120, Technical Data, MPPT Operating Voltage Range row, GW8.5K-MS-G40 column
Printed as "Nominal AC Grid Frequency (Hz) 50 / 60" in the GoodWe MS G4 Series datasheet (footer dated 2025-08-04, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe MS G4 Series datasheet, Technical Data, AC output table, merged cell
Printed as "Ingress Protection Rating IP66 IP66 IP66" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Ingress Protection Rating row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Outdoor single-core copper wire, conductor cross-sectional area 4-6mm2
Printed as "Type: Outdoor single-core copper wire" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), 5.2 Connecting the Protective Earth Wire, recommended specifications.
Where: PDF page 31, 5.2 Connecting the Protective Earth Wire, recommended specifications
Printed as "Max. Input Current per MPPT (A) 20 20 20" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Max. Input Current per MPPT row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 120, Technical Data, Max. Input Current per MPPT row, GW8.5K-MS-G40 column
Printed as "Max.Input Voltage (V)*2 600 600 600" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Max.Input Voltage row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 120, Technical Data, Max.Input Voltage row, GW8.5K-MS-G40 column
Printed as "GW8.5K-MS-G40 63A" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), 5.3 Connecting AC Output Cables, Inverter Model and AC Switch Specification table, GW8.5K-MS-G40 row. The manual gives these switch specifications "for reference" and asks for one AC output switch per inverter.
Where: PDF page 32, 5.3 Connecting AC Output Cables, Inverter Model and AC Switch Specification table, GW8.5K-MS-G40 row
The AC terminal drawing prints "1.0N·m" for the terminal screws in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), 5.3 Connecting AC Output Cables, AC terminal assembly drawing, step 2; read from rendered page 33. The same drawing prints "2.3-2.7N·m" for the 36mm cable gland nut, which is not a terminal torque and is not recorded here.
Where: PDF page 33, 5.3 Connecting AC Output Cables, AC terminal assembly drawing, step 2
Printed as "Start-up Voltage (V) 50 50 50" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Start-up Voltage row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 120, Technical Data, Start-up Voltage row, GW8.5K-MS-G40 column
The AC cable drawing prints "Cu, 10-16mm²" and "Φ:12-18mm" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), 5.3 Connecting AC Output Cables, AC cable preparation drawing, step 1; read from rendered page 33.
Where: PDF page 33, 5.3 Connecting AC Output Cables, AC cable preparation drawing, step 1
Printed as "Self-consumption at Night (W) <1" in the GoodWe MS G4 Series datasheet (footer dated 2025-08-04, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe MS G4 Series datasheet, Technical Data, General data table, merged cell
Printed as "Noise Emission (dB) <30 <30 <30" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Noise Emission (dB) row, GW8.5K-MS-G40 column. The bound is kept as printed; the manual prints the unit as dB.
Printed as "Number of Strings per MPPT 1 1 1" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Number of Strings per MPPT row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 120, Technical Data, Number of Strings per MPPT row, GW8.5K-MS-G40 column
Printed as "Nominal Output Power (W) 7500 8500 10000 7500 8000" in the GoodWe MS G4 Series datasheet (footer dated 2025-08-04, V2.1), AC output table, GW8.5K-MS-G40 column, captured on September 25, 2026.
Where: GoodWe MS G4 Series datasheet, Technical Data, AC output table, GW8.5K-MS-G40 column
Printed as "Recommended inverter installation angle: vertical or tilted back ≤ 15°" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), 4.1 Installation Requirements, Installation Angle Requirements. The manual adds: "Do not invert, tilt forward, tilt back beyond the angle, or install the inverter horizontally."
Where: PDF page 26, 4.1 Installation Requirements, Installation Angle Requirements
GoodWe prints no standby consumption figure for this model in the GoodWe MS G4 Series datasheet; its "Self-consumption at Night" row is recorded as night consumption. Revised on 30 September 2026: The 1 W figure is printed as consumption at night ("Self-consumption at Night"), not as standby consumption; it moves to night consumption and standby consumption is unknown.
Where: GoodWe MS G4 Series datasheet, Technical Data, General data table, merged cell
The drawing for the protective earth screw prints "M5" and "1.2-2N·m" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), 5.2 Connecting the Protective Earth Wire, step 3 drawing; read from rendered page 31.
Where: PDF page 31, 5.2 Connecting the Protective Earth Wire, step 3 drawing
Printed as "Max. Short Circuit Current per MPPT (A) 26 26 26" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Max. Short Circuit Current per MPPT row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 120, Technical Data, Max. Short Circuit Current per MPPT row, GW8.5K-MS-G40 column
Printed as "Operating Temperature Range (℃) -25~+60 -25~+60 -25~+60" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, Operating Temperature Range row, GW8.5K-MS-G40 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 123, Technical Data, Operating Temperature Range row, GW8.5K-MS-G40 column
Printed as "European Efficiency 97.2% 97.3% 97.3%" in GoodWe's MS G4 Series user manual (V1.5-2026-04-15), Technical Data, European Efficiency row, GW8.5K-MS-G40 column. The GW8.5K-MS-G40 column reads "97.3%". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 122, Technical Data, European Efficiency row, GW8.5K-MS-G40 column
33.65 L* (Calculated from published dimensions)W: 493 × H: 365 × D: 187 mm / W: 19.4 × H: 14.4 × D: 7.36 inWeight16 kg / 35 lb
Evidence score
6/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term5 years6.0 / 30.0
5 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed in item 1 of the GOODWE Limited Warranty for Inverter System (for Global market), Rev: 5.3 20260917, captured on September 25, 2026, which lists the MS G4 series under a 5-year limited warranty. The policy names series, not models, and applies only in the international market its Geographical Scope clause defines (it excludes America, Canada, Brazil, Europe, Australia, New Zealand and greater China); exclusions and claim steps apply.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Territory
International market except China mainland, Hong Kong, Macao, Taiwan, Australia, New Zealand, America, Canada, Brazil and European countries
Printed as "This GOODWE Limited warranty terms and conditions applies for international market except China mainland, Hong Kong, Macao, Taiwan, Australia, New Zealand, America, Canada, Brazil or European countries" in the Geographical Scope clause of the same policy, captured on September 25, 2026; those regions have separate GoodWe terms.
Earlier of first installation or 6 months after production
Printed as "starting from the earlier one of following two dates: 1. The date on which the product was first installed. 2. 6 months after the date of production." in the same policy, captured on September 25, 2026.
Global-market policy; not the United States or Canada
Printed in item 1 of the GOODWE Limited Warranty for Inverter System (for Global market), Rev: 5.3 20260917, captured on September 25, 2026, which lists the MS G4 series under a 5-year limited warranty. The policy names series, not models, and applies only in the international market its Geographical Scope clause defines (it excludes America, Canada, Brazil, Europe, Australia, New Zealand and greater China); exclusions and claim steps apply.
Location: PDF page 3, Applicable Model table; PDF pages 120 to 129, Technical Data
Retrieved Oct 1, 2026
GoodWe's own user manual for the MS G4 Series single-phase grid-tied inverters, linked as the User Manual from GoodWe's MS G4 product page and captured 1 October 2026 from en.goodwe.com; revision V1.5-2026-04-15 as printed. Its Applicable Model table names GW7.5K-MS-G40, GW8.5K-MS-G40, GW9.999K-MS-G40, GW10K-MS-G40, GW7.5K-MS-G41 and GW8K-MS-G40 (printed there as "GW8K-MS -G40") with the Chinese -CN-G40 variants. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Technical Data table, one column per model
Retrieved Sep 24, 2026
GoodWe family datasheet (MS G4 Series), fetched from en.goodwe.com (the file the series page en.goodwe.com/ms-g4 links as "Datasheet") and archived on September 25, 2026. Its Technical Data table sets the models side by side, one column per model, so each figure is read from the named model column and the whole row is quoted; a value printed once spans every column. It names models, not ordering SKUs. It is a manufacturer claim; no figure was tested independently.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Overview and Geographical Scope
Retrieved Sep 24, 2026
GoodWe limited warranty for inverters sold in its global market. It names series, not models: 5 years for the on-grid and hybrid series it lists. Fetched from en.goodwe.com (linked from en.goodwe.com/warranty) and archived on September 25, 2026. The policy's Geographical Scope clause limits it to devices bought from authorized channels and installed in the international market it defines, which excludes the regions GoodWe covers with separate terms (the United States and Canada among them). It is the manufacturer's published policy, not a purchaser-specific contract.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
GoodWe MS G4 Series datasheet (GoodWe-Single page-20250804-EN-V2.1)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
GOODWE Limited Warranty for Inverter System (for Global market), Rev: 5.3 20260917
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
GoodWe MS G4 Series Grid-Tied PV Inverter User Manual (V1.5-2026-04-15)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].