Printed as "34" in the GW5K-ETA-G20 column of the Weight (kg) row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 286 (printed page 285); read from the rendered page and checked against the text layer.
Printed as "3" in the GW5K-ETA-G20 column of the Number of MPPTs row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer.
Printed as "Off-grid: 5.5 (10.0, 10s), on-grid: 43.5" in the GW5K-ETA-G20 column of the Max. Apparent Power (kVA) row (AC Side (Back-up Port)) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 283 (printed page 282); read from the rendered page and checked against the text layer. Back-up port maximum apparent power (kVA); the first figure is the continuous one and the bracket gives the 10-second figure. The table's footnote *7 says "Off grid" means the back-up output comes only from PV and battery and "On grid" that it includes energy from the grid or a generator side.
Location: User manual PDF page 283 (printed page 282), 9.1 Inverter Parameters, AC Side (Back-up Port) section, Max. Apparent Power (kVA) row, GW5K-ETA-G20 column
Printed as "220/380, 230/400, 3L/N/PE" in the GW5K-ETA-G20 column of the Nominal Voltage (V) row (AC Side (Grid Port)) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 282 (printed page 281); read from the rendered page and checked against the text layer.
Location: User manual PDF page 282 (printed page 281), 9.1 Inverter Parameters, AC Side (Grid Port) section, Nominal Voltage (V) row, GW5K-ETA-G20 column
Printed as "6.7" in the GW5K-ETA-G20 column of the Max. Continuous Charging Current (A) row (Battery Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Location: User manual PDF page 280 (printed page 279), 9.1 Inverter Parameters, Battery Side section, Max. Continuous Charging Current (A) row, GW5K-ETA-G20 column
Documented
Dimensions
73.44 L*Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 800 × H: 340 × D: 270 mmW: 31.5 × H: 13.4 × D: 10.6 in convertedOfficial user manualSources
Printed as "800*340*270" in the GW5K-ETA-G20 column of the Dimension (W×H×D mm) row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 286 (printed page 285); read from the rendered page and checked against the text layer. The row is headed W×H×D.
Printed as "98.00%" in the GW5K-ETA-G20 column of the Max. Efficiency row (Efficiency) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer.
Printed as "120~950" in the GW5K-ETA-G20 column of the MPPT Operating Voltage Range (V) row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer.
Location: User manual PDF page 281 (printed page 280), 9.1 Inverter Parameters, PV Side section, MPPT Operating Voltage Range (V) row, GW5K-ETA-G20 column
Documented
All specs28
Peak output
Off-grid: 5.5 kVA, 10.0 kVA for 10 s; on-grid: 43.5 kVA
Printed as "Off-grid: 5.5 (10.0, 10s), on-grid: 43.5" in the GW5K-ETA-G20 column of the Max. Apparent Power (kVA) row (AC Side (Back-up Port)) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 283 (printed page 282); read from the rendered page and checked against the text layer. Back-up port maximum apparent power (kVA); the first figure is the continuous one and the bracket gives the 10-second figure. The table's footnote *7 says "Off grid" means the back-up output comes only from PV and battery and "On grid" that it includes energy from the grid or a generator side.
Location: User manual PDF page 283 (printed page 282), 9.1 Inverter Parameters, AC Side (Back-up Port) section, Max. Apparent Power (kVA) row, GW5K-ETA-G20 column
Printed as "220/380, 230/400, 3L/N/PE" in the GW5K-ETA-G20 column of the Nominal Voltage (V) row (AC Side (Grid Port)) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 282 (printed page 281); read from the rendered page and checked against the text layer.
Location: User manual PDF page 282 (printed page 281), 9.1 Inverter Parameters, AC Side (Grid Port) section, Nominal Voltage (V) row, GW5K-ETA-G20 column
Printed as "6.7" in the GW5K-ETA-G20 column of the Max. Continuous Charging Current (A) row (Battery Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Printed as "98.00%" in the GW5K-ETA-G20 column of the Max. Efficiency row (Efficiency) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer.
Printed as "50/60" in the GW5K-ETA-G20 column of the Nominal Frequency (Hz) row (AC Side (Grid Port)) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 282 (printed page 281); read from the rendered page and checked against the text layer.
Location: User manual PDF page 282 (printed page 281), 9.1 Inverter Parameters, AC Side (Grid Port) section, Nominal Frequency (Hz) row, GW5K-ETA-G20 column
Printed as "7.4" in the GW5K-ETA-G20 column of the Max. Continuous Discharging Current (A) row (Battery Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Printed as "three phase" in the GW5K-ETA-G20 column of the Type of Electrical Supply System row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 287 (printed page 286); read from the rendered page and checked against the text layer. From the Type of Electrical Supply System row.
Location: User manual PDF page 287 (printed page 286), 9.1 Inverter Parameters, General Data section, Type of Electrical Supply System row, GW5K-ETA-G20 column
Printed as "5.5" in the GW5K-ETA-G20 column of the Max. Discharging Power (kW) row (Battery Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Printed as "750" in the GW5K-ETA-G20 column of the Nominal Voltage (V) row (Battery Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Printed as "5" in the GW5K-ETA-G20 column of the Max. Charging Power (kW) row (Battery Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Printed as "≤10" in the GW5K-ETA-G20 column of the Self-consumption at Night (W) row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 286 (printed page 285); read from the rendered page and checked against the text layer. Printed with a less-than-or-equal sign ("≤10"): the figure is an upper limit, recorded as 10 W.
Location: User manual PDF page 286 (printed page 285), 9.1 Inverter Parameters, General Data section, Self-consumption at Night (W) row, GW5K-ETA-G20 column
Printed as "5" in the GW5K-ETA-G20 column of the Rated Power (kW) row (AC Side (Grid Port)) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer.
Printed as "98.00%" in the GW5K-ETA-G20 column of the Max. Battery to AC Efficiency row (Efficiency) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer.
Printed as "700~950" in the GW5K-ETA-G20 column of the Voltage Range (V) row (Battery Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Printed as "96.40%" in the GW5K-ETA-G20 column of the European Efficiency row (Efficiency) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer.
Printed as "3" in the GW5K-ETA-G20 column of the Number of MPPTs row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer.
Printed as "120~950" in the GW5K-ETA-G20 column of the MPPT Operating Voltage Range (V) row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer.
Location: User manual PDF page 281 (printed page 280), 9.1 Inverter Parameters, PV Side section, MPPT Operating Voltage Range (V) row, GW5K-ETA-G20 column
Printed as "10" in the GW5K-ETA-G20 column of the Max. Input Power (kW) row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 280 (printed page 279); read from the rendered page and checked against the text layer.
Printed as "21/21/21" in the GW5K-ETA-G20 column of the Max. MPPT Current (A) row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer. One figure per MPPT, in MPPT order.
Printed as "1000" in the GW5K-ETA-G20 column of the Max. Input Voltage (V) row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer.
Printed as "150" in the GW5K-ETA-G20 column of the Start-up Voltage (V) row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer.
Printed as "1/1/1" in the GW5K-ETA-G20 column of the Number of Strings per MPPT row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer. One figure per MPPT, in MPPT order.
Printed as "26/26/26" in the GW5K-ETA-G20 column of the Max. MPPT Short Circuit Current (A) row (PV Side) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 281 (printed page 280); read from the rendered page and checked against the text layer. One figure per MPPT, in MPPT order.
Location: User manual PDF page 281 (printed page 280), 9.1 Inverter Parameters, PV Side section, Max. MPPT Short Circuit Current (A) row, GW5K-ETA-G20 column
Printed as "34" in the GW5K-ETA-G20 column of the Weight (kg) row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 286 (printed page 285); read from the rendered page and checked against the text layer.
Location: User manual PDF page 286 (printed page 285), 9.1 Inverter Parameters, General Data section, Weight (kg) row, GW5K-ETA-G20 column
Documented
Dimensions
73.44 L*Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 800 × H: 340 × D: 270 mmW: 31.5 × H: 13.4 × D: 10.6 in convertedOfficial user manualSources
Printed as "800*340*270" in the GW5K-ETA-G20 column of the Dimension (W×H×D mm) row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 286 (printed page 285); read from the rendered page and checked against the text layer. The row is headed W×H×D.
Printed as "IP66" in the GW5K-ETA-G20 column of the Ingress Protection Rating row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 286 (printed page 285); read from the rendered page and checked against the text layer.
Printed as "Wall/Floor Mounted" in the GW5K-ETA-G20 column of the Mounting Method row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 287 (printed page 286); read from the rendered page and checked against the text layer.
Printed as "-35~+60" in the GW5K-ETA-G20 column of the Operating Temperature Range (℃) row (General Data) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 285 (printed page 284); read from the rendered page and checked against the text layer.
Location: User manual PDF page 285 (printed page 284), 9.1 Inverter Parameters, General Data section, Operating Temperature Range (℃) row, GW5K-ETA-G20 column
Documented
Published claims and calculations, not independent test results.
Documents
1 on file
WEB
ESA Series 5-30kW user manual (GoodWe, V1.5, 2026-09-04)OfficialGoodWe Technologies Co., Ltd.Official user manualSeptember 4, 2026
Source details
Revision
V1.5
Revision date
September 4, 2026
Archived copy captured on 2026-09-29.
Location: Applicable Products; Battery Technical Data
Retrieved
GoodWe's user manual for the three-phase ESA Series, linked as "User Manual" from the ESA 5-30kW page; the link resolves to en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_ESA-5-30kW_User-Manual-EN.pdf. Captured September 29, 2026. It lists the six GW...-BAT-D-G20/G21 modules among its applicable products and prints their Battery Technical Data; it is the most recent manual covering them and is used as the primary source. Manufacturer claims, not independently verified.
Archived copies
Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
ESA Series 5-30kW user manual (GoodWe, V1.5, 2026-09-04)
Archived copy of a document published by GoodWe Technologies Co., Ltd.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Battery conversion efficiency98 %15.0 / 15.0
98 of 98.2 %, the best documented for an inverter (printed by the maker): GoodWe GW100K-ET-G10
Printed as "98.00%" in the GW5K-ETA-G20 column of the Max. Battery to AC Efficiency row (Efficiency) of the 9.1 Inverter Parameters table in GoodWe's ESA Series 5-30kW user manual (V1.5, 2026-09-04), PDF page 284 (printed page 283); read from the rendered page and checked against the text layer.
Research pending, 0 points: Certificates, Warranty term, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5