Printed as "Weight (kg) ≤5.1kg" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Weight row, GW1.8K-MIS-G20 column. The bound is kept as printed.
Where: PDF page 59, Technical Data, Weight row, GW1.8K-MIS-G20 column
Printed as "Number of MPP Trackers 4 4 4 4 4 4" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Number of MPP Trackers row, GW1.8K-MIS-G20 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 54, Technical Data, Number of MPP Trackers row, GW1.8K-MIS-G20 column
Printed as "Nominal Voltage (V) 220 / 230 / 240, L / N / PE" in the GoodWe MIS G2 Series (1600-2500W) datasheet (footer dated 2026-07-13, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe MIS G2 Series (1600-2500W) datasheet, Technical Data, AC output table, merged cell
W 318 × H 226 × D 37.5 mm / W 12.5 × H 8.9 × D 1.48 in converted
Printed as "Dimension (W × H × D mm) 318 × 226 × 37.5" in the GoodWe MIS G2 Series (1600-2500W) datasheet (footer dated 2026-07-13, V2.1), General data table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe MIS G2 Series (1600-2500W) datasheet, Technical Data, General data table, merged cell
Printed as "WiFi、 Bluetooth" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Communication row, GW1.8K-MIS-G20 column. The protocol row reads "Modbus".
Where: PDF page 59, Technical Data, Communication row, GW1.8K-MIS-G20 column
Printed as "Max. Efficiency 96.0% 96.0%" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Max. Efficiency row, GW1.8K-MIS-G20 column. Printed as 96.0%; recorded as 96. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Printed as "MPPT Operating Voltage Range (V) *3 12~60 12~60" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, MPPT Operating Voltage Range row, GW1.8K-MIS-G20 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 53, Technical Data, MPPT Operating Voltage Range row, GW1.8K-MIS-G20 column
Printed as "Nominal Frequency (Hz) 50 / 60" in the GoodWe MIS G2 Series (1600-2500W) datasheet (footer dated 2026-07-13, V2.1), AC output table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe MIS G2 Series (1600-2500W) datasheet, Technical Data, AC output table, merged cell
Printed as "Ingress Protection Rating IP67 IP67" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Ingress Protection Rating row, GW1.8K-MIS-G20 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Printed as "Recommended specification: 6mm2 (10AWG)." in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), 5.2 Connecting the PE cable, recommended specification. The manual asks for an M4 grounding OT terminal.
Where: PDF page 30, 5.2 Connecting the PE cable, recommended specification
Printed as "Max. Input Voltage (V) *2 60 60 60 60 60 60" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Max. Input Voltage row, GW1.8K-MIS-G20 column. Footnote 2 on PDF page 61 reads "When the input voltage exceeds 65V, the inverter will enter standby mode". Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 53, Technical Data, Max. Input Voltage row, GW1.8K-MIS-G20 column
Printed as "GW1.8K-MIS-G20 16A 25A 32A 40A -" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), 5.3 Connecting AC Output Cables, AC Switch Specifications table, GW1.8K-MIS-G20 row. The table gives the AC switch for one to five inverters on one branch "for reference"; a dash means that number of units is not listed.
Where: PDF page 31, 5.3 Connecting AC Output Cables, AC Switch Specifications table, GW1.8K-MIS-G20 row
Printed as "Start-up Voltage (V) 15 15 15 15 15 15" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Start-up Voltage row, GW1.8K-MIS-G20 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 53, Technical Data, Start-up Voltage row, GW1.8K-MIS-G20 column
Printed as "on at Night (W) <0.05" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Power Self-consumption at Night (W) row, GW1.8K-MIS-G20 column. The row is printed as "Power Self- consumption at Night (W)"; the bound is kept as printed.
Where: PDF page 59, Technical Data, Power Self-consumption at Night (W) row, GW1.8K-MIS-G20 column
Printed as "Noise Emission (dB) ≤20" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Noise Emission (dB) row, GW1.8K-MIS-G20 column. The bound is kept as printed; the manual prints the unit as dB.
Printed as "Number of Strings per MPPT 1 1 1 1 1 1" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Number of Strings per MPPT row, GW1.8K-MIS-G20 column. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 54, Technical Data, Number of Strings per MPPT row, GW1.8K-MIS-G20 column
Printed as "Rated Power (kW) 1.6 1.8 1.875 2.0 2.25 2.5" in the GoodWe MIS G2 Series (1600-2500W) datasheet (footer dated 2026-07-13, V2.1), AC output table, GW1.8K-MIS-G20 column, captured on September 25, 2026.
Where: GoodWe MIS G2 Series (1600-2500W) datasheet, Technical Data, AC output table, GW1.8K-MIS-G20 column
Printed as "Mounting Method Wall Mounted" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Mounting Method row, GW1.8K-MIS-G20 column.
The grounding drawing prints "M4" and "1.6N·m" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), 5.2 Connecting the PE cable, step 3 drawing; read from rendered page 30.
Where: PDF page 30, 5.2 Connecting the PE cable, step 3 drawing
Printed as "Max. Short Circuit Current per MPPT (A) 26 / 26 / 26 / 26*3" in the GoodWe MIS G2 Series (1600-2500W) datasheet (footer dated 2026-07-13, V2.1), PV input table, one value printed for every model in the table, captured on September 25, 2026.
Where: GoodWe MIS G2 Series (1600-2500W) datasheet, Technical Data, PV input table, merged cell
Printed as "﹣40~+6 5(>50 derating)" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, Operating Temperature Range row, GW1.8K-MIS-G20 column. The text layer splits the figure as "+6 5"; the table reads -40 to +65 °C with derating above 50 °C.
Where: PDF page 58, Technical Data, Operating Temperature Range row, GW1.8K-MIS-G20 column
Printed as "European Efficiency 95.0% 95.0%" in GoodWe's MIS G2 Series (1600-2500W) user manual (V1.0 2026-07-15), Technical Data, European Efficiency row, GW1.8K-MIS-G20 column. Printed as 95.0%; recorded as 95. Re-cited on 1 October 2026 to the manufacturer's own document; previously cited to GoodWe (en.goodwe.com), which stays listed as an additional source.
Where: PDF page 57, Technical Data, European Efficiency row, GW1.8K-MIS-G20 column
2.7 L* (Calculated from published dimensions)W: 318 × H: 226 × D: 37.5 mm / W: 12.5 × H: 8.9 × D: 1.48 in
Evidence score
18/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term15 years18.0 / 30.0
15 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "15-year standard warranty" in the feature list of the GoodWe MIS G2 Series (1600-2500W) datasheet, captured on September 25, 2026. The datasheet prints no warranty conditions or region.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
15 years
Printed as "15-year standard warranty" in the feature list of the GoodWe MIS G2 Series (1600-2500W) datasheet, captured on September 25, 2026. The datasheet prints no warranty conditions or region.
Location: PDF page 3, Applicable Model table; PDF pages 53 to 61, Technical Data
Retrieved Oct 1, 2026
GoodWe's own user manual for the MIS G2 Series (1600-2500W) microinverters, linked as the User Manual from GoodWe's MIS G2 Series product page and captured 1 October 2026 from en.goodwe.com; revision V1.0 2026-07-15 as printed. Its Applicable Model table names GW1.6K-MIS-G20, GW1.8K-MIS-G20, GW1.875K-MIS-G20, GW2K-MIS-G20, GW2.25K-MIS-G20 and GW2.5K-MIS-G20. Manufacturer instructions, not independent tests.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Captured by scripts/prepare-brand-sweep-sep21.mjs on 2026-09-25.
Location: Technical Data table, one column per model
Retrieved Sep 24, 2026
GoodWe family datasheet (MIS G2 Series (1600-2500W)), fetched from en.goodwe.com (the file the series page en.goodwe.com/mis-g2-series-1600-2500w links as "Datasheet") and archived on September 25, 2026. Its Technical Data table sets the models side by side, one column per model, so each figure is read from the named model column and the whole row is quoted; a value printed once spans every column. It names models, not ordering SKUs. It is a manufacturer claim; no figure was tested independently.
Archived copies
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
GoodWe MIS G2 Series (1600-2500W) datasheet (GoodWe-Single page-20260713-EN-V2.1)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
GoodWe MIS G2 Series (1600-2500W) Microinverter User Manual (V1.0 2026-07-15)
Archived copy of a document published by GoodWe. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product. CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED ‘AS IS’ AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.