Key specs

Units
SKU
APKE00075
Official datasheet
Sources

Generac's model number, printed in the inverter section heading.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter heading

Documented

Weight
28.16 kg62.08 lb converted
Official datasheet
Sources

Printed as 62.1 lb (28.16 kg).

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, Mechanical

Documented

Device type
Battery inverter
Official datasheet
Sources

As Generac prints it (Lead Engineer, November 3, 2026).

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter

Documented

AC voltage
120 V / 240 V, single phase
Official datasheet
Sources

The nominal grid voltage row.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, AC Output

Documented

Dimensions
72.91 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 205.7 × H: 612.1 × L: 579.1 mmW: 8.1 × H: 24.1 × L: 22.8 in convertedOfficial datasheet
Sources

Converted: cm x 10 mm/cm

Printed as 57.91 x 20.57 x 61.21 cm; the system table orders these L x W x H.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, Mechanical

Calculated

Enclosure
NEMA 3R
Official datasheet
Sources

The enclosure rating row.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, Environmental

Documented

Battery voltage
400 V
Official datasheet
Sources

The nominal DC input voltage.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, DC Input

Documented

Certifications (as printed)
UL 1741; UL 1741 SA11; UL 1741 SB; UL 1998; IEEE 1547; IEEE 1547a; IEEE 1547.1; CA Rule 21; Rule 14H (HECO SRD V2.0); ISO-NE; PRC-024; Regulation No. 8915 (PREPA); CSIP
Official datasheet
Sources

The certifications row. Manufacturer claims, no issuer directory was checked.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, Compliance

Documented

Continuous output
11.5 kW
Official datasheet
Sources

Footnote 1: limited by battery power; 11.5 kW needs two cabinets with at least 7 modules.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, AC Output

Documented

All specs12
AC voltage
120 V / 240 V, single phase
Official datasheet
Sources

The nominal grid voltage row.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, AC Output

Documented

Battery voltage
400 V
Official datasheet
Sources

The nominal DC input voltage.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, DC Input

Documented

Continuous output
11.5 kW
Official datasheet
Sources

Footnote 1: limited by battery power; 11.5 kW needs two cabinets with at least 7 modules.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, AC Output

Documented

Continuous AC current
48 A
Official datasheet
Sources

The maximum continuous AC current row.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, AC Output

Documented

Battery operating voltage
360 to 420 V
Official datasheet
Sources

The DC input voltage range row.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, DC Input

Documented

Weighted efficiency
98.5 %
Official datasheet
Sources

CEC weighted efficiency.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, Performance

Documented

Published claims and calculations, not independent test results.

Documents

1 on file
  • PDF
    Generac PWRcell 2 Specification Sheet (A0008625505 Rev C)OfficialGenerac Power Systems, Inc.Official datasheet
    Source details
    Revision
    A0008625505 REV C
    Revision date
    Not stated

    Location: Page 5, 3.0 kWh DCB Battery Module, MODEL NUMBER: G0080041

    Retrieved

    Eight-page English specification sheet for the PWRcell 2 system, linked from Generac's solar battery storage page (www.generac.com/home-energy-system/solar-battery-storage/), captured on September 28, 2026. Page 5 prints the 3.0 kWh DCB Battery Module under its own model number G0080041 with its own specification list; the other pages cover the cabinet, inverter, Smart Disconnect Switch and PWRmanager. Its compliance line is a manufacturer claim that no issuer record was read against.

    Archived copies

    Archived copy of a document published by Generac Power Systems, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup A0008625505 REV C · 1.59 MB

    Archived copy, unaltered, kept as a record of what Generac Power Systems, Inc. published. Original address: https://www.generac.com/globalassets/residential/dealers--installers/generac-installer-programs/solar--battery-installer-support/pwrcell2_specsheet.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    8
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 6a79debfa32777543566ae01626ef053b99885927b33261adee0950610dd01c9

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Generac PWRcell 2 Specification Sheet (A0008625505 Rev C)

Archived copy of a document published by Generac Power Systems, Inc.. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup A0008625505 REV C · 1.59 MB

Archived copy, unaltered, kept as a record of what Generac Power Systems, Inc. published. Original address: https://www.generac.com/globalassets/residential/dealers--installers/generac-installer-programs/solar--battery-installer-support/pwrcell2_specsheet.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
8
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 6a79debfa32777543566ae01626ef053b99885927b33261adee0950610dd01c9

Submit a document

Warranty

Product warranty
10 years
Official datasheet
Sources

Printed as 10 years.

Official datasheet: Generac PWRcell 2 Specification Sheet (A0008625505 Rev C) Rev A0008625505 REV C · Checked · Earlier document

Location: PDF page 6, PWRcell 2 Inverter, Performance

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

12/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 7 to 15 kW output band. · Method version 0.5

How it works

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
APKE00075

Manufacturer SKU APKE00075 · US market

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.