Charged ReviewsSaved 0Compare 0Login
Felicity Solar IVGM5KLP1G1 5 kW Single-Phase Hybrid Inverter
Felicity Solar
Hybrid inverter

Felicity Solar IVGM5KLP1G1 5 kW Single-Phase Hybrid Inverter

Key specs

Weight33.5 kg / 73.9 lb converted
Max PV voltage500 V
Efficiency97.6 %
Max charge120 A
MPPT count2
PV start voltage100 V

All specifications

Identity

BrandFelicity Solar · Website
ModelIVGM5KLP1G1
MarketUnknown
Manufacturer SKUIVGM5KLP1G1
About brandFelicity Solar (Felicitysolar) makes off-grid and hybrid solar inverters, LiFePO4 batteries and energy storage systems, and lists them with datasheets and manuals on its own site at felicitysolar.com, which serves North American visitors from felicitysolar.us.
SKU detail
locator: Detail Specifications table, Model row
conditions: Printed as the model "IVGM5KLP1G1" in its own column of the Detail Specifications table on the IVGM5~8kW-P1G1 page, captured October 20, 2026. The page's product data names the series ("IVGM5~8kW-P1G1"), not this model.
Sources: [1]
FieldValueConditionsSource
Weight33.5 kg / 73.9 lb converted
Printed as "Net Weight 33.5KG" in Appendix I, one value for all four models; Table 2.3-1 also prints 33.5 kg for all four.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]
MPPT count2
Printed as "Two MPPT trackers, four PV input channels" in the feature list for the series.
Where: What sets it apart, Dual MPPT + 4 PV Inputs
[1]
AC voltage220/230 V AC (single phase)
Printed as "Rated AC output voltage 220/230Va.c (single phase)" under AC Output Data(Back Up).
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]
Max charge120 A
Printed as "120 A / 120 A" in the IVGM5KLP1G1 column; the charge figure is recorded.
Where: Detail Specifications table, Max. Battery Charge / Discharge Current
[1]
Dimensions430 × 654 × 243 mm / 16.9 × 25.7 × 9.57 in converted
Printed as "Product Dimension 430×654x243MM" in Appendix I, one value for all four models. The table does not name the axes, so the figures are kept in the printed order; Figure 2.3-2 draws the unit 430 mm wide, 654 mm tall and 243 mm deep.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]
Efficiency97.6 %
Printed as "Maximum Efficiency 97.6%". The cell spans all four columns.
Where: Detail Specifications table, Maximum Efficiency
[1]
MPPT voltage120 to 425 V
Printed as "MPPT Voltage Range 120-425 V". The cell spans all four columns.
Where: Detail Specifications table, MPPT Voltage Range
[1]
Solar array7.5 kW
Converted: 7500 W / 1000 W/kW
Printed as "Max. recommended PV power 7500W" in the IVGM5KL P1G1 column; expressed in kW.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
Sources
Converted: 7500 W / 1000 W/kW
[2]
AC frequency50/60Hz
Printed as "Rated AC output frequency 50/60Hz" under AC Output Data(Back Up).
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]
Max discharge120 A
Printed as "120 A / 120 A" in the IVGM5KLP1G1 column; the discharge figure is recorded.
Where: Detail Specifications table, Max. Battery Charge / Discharge Current
[1]
Backup output5 kW
Printed as "5 kW" in the IVGM5KLP1G1 column. The page does not call it continuous, so no continuous output is recorded.
Where: Detail Specifications table, Rated Backup Output Power
[1]
Enclosure ratingIP65
Printed as "IP65 Protection" in the feature list for the series.
Where: What sets it apart, IP65 Protection
[1]
Max PV current13 A + 13 A
Printed as "13 A + 13 A" in the IVGM5KLP1G1 column.
Where: Detail Specifications table, PV Input Current
[1]
Max PV voltage500 V
Printed as "Max. PV Voltage 500 V". The cell spans all four columns.
Where: Detail Specifications table, Max. PV Voltage
[1]
Transfer timeLess than 10 ms
Printed as "Less Than 10 ms Switching" in the feature list for the series.
Where: What sets it apart, Less Than 10 ms Switching
[1]
Grid passthrough40 A
Printed as "Max. Continuous AC Passthrough 40A" in the IVGM5KL P1G1 column.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]
PV start voltage100 V
Printed as "Start voltage 100V"; the cell spans all four columns.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]
Battery voltage range40 to 60 V
Printed as "Battery Voltage Range 40-60 V". The cell spans all four columns.
Where: Detail Specifications table, Battery Voltage Range
[1]
Operating temperature-25 to 60 °C / -13 to 140 °F converted
Printed as "Operating temperature range -25°C~60°C,>45°C Derating": output is derated above 45°C.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]
Weighted efficiency97 %
Printed as "Euro efficiency 97%"; the cell spans all four columns.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]

Owner reviews

No owner reviews yet
Write a review

Sellers

No listed sellers in this data.

Price history

No seller price history.

Quick reference sheet

Continuous output
Not yet documented
Battery voltage
40 to 60 V
Solar input
7.5 kWMPPT trackers 2MPPT range 120 to 425 V
AC output
220/230 V AC (single phase)
Warranty
10 years
Size
68.34 L* (Calculated from published dimensions)430 × 654 × 243 mm / 16.9 × 25.7 × 9.57 inWeight 33.5 kg / 73.9 lb

Evidence score

12/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Warranty term10 years12.0 / 30.0

10 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3

Printed as "Warranty[1] 10 years"; the footnote says conditions apply and refers to the Felicitysolar warranty policy.

[2]

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5

How it works

Certificates

What this shows: what each record says and how far it reaches. It does not mean the product is approved.

Unknown: no certification evidence recorded in this data.

Warranty

FieldValueConditionsSource
Warranty term10 years
Printed as "Warranty[1] 10 years"; the footnote says conditions apply and refers to the Felicitysolar warranty policy.
Where: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)
[2]

Recalls / legal notices

No recalls on file. All notices · Report a notice

This register is incomplete. A missing notice does not establish that a product has no recalls.

Documents

  • Manuals

  • Felicity Solar IVGM5KLP1G1 to IVGM8KLP1G1 user guide (printed document code 358-010498-00)Official · Felicity Solar · Official user manual · PDF
    Source details
    Revision
    358-010498-00
    Revision date
    Not stated

    Archived copy captured on 2026-10-20.

    Location: Appendix I (PDF page 31, printed pages 57 and 58) and Table 2.3-1 (PDF page 5)

    Retrieved Oct 20, 2026

    Felicity Solar's own user manual, a PDF the maker publishes on its main site www.felicitysolar.com; obtained by the Alternative Research chat on October 20, 2026 from the maker's main site, and kept unchanged. It carries printed document code 358-010498-00 and no date. Manufacturer claims, not independent tests. It is an upload on the maker's main site; whether it matches the current file on doc.felicitysolar.com, which refused the research fetcher, is not known.

    Archived copies

    Archived copy of a document published by Felicity Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

    Archived backup358-010498-00 · 24.37 MB

    Archived copy, unaltered, kept as a record of what Felicity Solar published. Original address: https://www.felicitysolar.com/wp-content/uploads/2025/07/IVGM8KLP1G1.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Embedded creation date
    Embedded modification date
    Pages
    32

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: 5cc6c4385392e7b8329bf31ca0a624dc40b11168bc19055b8fb379275f86f8ff

    Open
  • Other documents

  • Felicity Solar product page: IVGM5~8kW-P1G1 (IVGM5KLP1G1, IVGM6KLP1G1, IVGM7K6LP1G1, IVGM8KLP1G1) (October 20, 2026 capture)Official · Felicity Solar · Official product page · Web page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    Archived copy captured on 2026-10-20.

    Location: Product heading; What sets it apart; Detail Specifications table; product data

    Retrieved Oct 20, 2026

    Felicity Solar's own product page, requested at www.felicitysolar.com and captured on October 20, 2026 with the paced research fetcher; the maker's server redirected the request to the same page on its North American site, felicitysolar.us, and the capture is whatever that address served on that date. Read for the product heading, the feature list, the Detail Specifications table and the product data (SKU and images). Manufacturer claims, not independent tests; the page carries no revision date. The datasheets and manuals it links on doc.felicitysolar.com were not captured because that host refused the fetcher (HTTP 403 on its robots.txt).

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

Felicity Solar IVGM5KLP1G1 to IVGM8KLP1G1 user guide (printed document code 358-010498-00)

Archived copy of a document published by Felicity Solar. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].

Archived backup358-010498-00 · 24.37 MB

Archived copy, unaltered, kept as a record of what Felicity Solar published. Original address: https://www.felicitysolar.com/wp-content/uploads/2025/07/IVGM8KLP1G1.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Embedded creation date
Embedded modification date
Pages
32

Embedded dates are file metadata, not independent proof of publication.

SHA-256: 5cc6c4385392e7b8329bf31ca0a624dc40b11168bc19055b8fb379275f86f8ff

Submit a document

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
IVGM5KLP1G1

Manufacturer SKU IVGM5KLP1G1

No historical observations recorded yet.

Other recorded fields

FieldValueConditionsSource
Evidence breakdown
method version: inverters-0.5-personal
documented pct: 30
basis: Unknown
missing:
Certificate evidence needed
Battery conversion efficiency needed
Idle consumption needed
criteria:
key: certificates
label: Certificates
value: 0
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 45
weight: 45
share: 0
covered: no
missing: yes
folded: yes
reason: Unknown
reason text: Unknown
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: 10
unit: Unknown
shown: 10 years
shown detail: Unknown
state: documented
points: 12
ceiling: 30
weight: 30
share: 40
covered: yes
missing: no
folded: no
reason: Unknown
reason text: Unknown
note:
display note: Unknown
Sources: [2]
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 10
weight: 10
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record

Community discussions

No discussions linked yet. Search DIY Solar Forum

Sources

  1. Felicity Solar product page: IVGM5~8kW-P1G1 (IVGM5KLP1G1, IVGM6KLP1G1, IVGM7K6LP1G1, IVGM8KLP1G1) (October 20, 2026 capture) (Felicity Solar · manufacturer · observed Oct 20, 2026)
  2. Felicity Solar IVGM5KLP1G1 to IVGM8KLP1G1 user guide (printed document code 358-010498-00) (Felicity Solar · manufacturer · 358-010498-00 · observed Oct 20, 2026)

Sign in to report an error on this page

Similar products

All with a price

* Missing details