Charged ReviewsSaved 0Compare 0Login

Charged Reviews · Quick reference

Enphase IQ7 Microinverter IQ7-60-2-US

Brand
Enphase
Model
IQ7-60-2-US
SKU / part number
IQ7-60-2-US [1] [2]
Category
Inverters

chargedreviews.com/inverters/enphase-iq7-60-2-us

AC output

Continuous output
?
Peak output
250 VA [1]
AC configuration
240 VAC (single phase); 208 VAC (single phase) [1]
AC output voltage
240 VAC (single phase); 208 VAC (single phase) [1]
AC frequency
60 Hz (nominal); extended frequency range 47 to 68 Hz [1]
Grid pass-through
?
Maximum output per leg
?

Battery

Battery voltage
?
Battery voltage range
16 to 48 V [1]
Maximum charge current
?
Maximum discharge current
?
Battery-only output
?
Maximum grid charging
?
Compatible batteries / BMS
?

PV input

PV array limit (connected)
?
PV input limit (converted)
?
Maximum PV voltage (Voc)
48 V Needs confirmation [1]
MPPT voltage range
27 to 37 V [1] [2]
MPPT trackers
?
String inputs per MPPT
?
PV current per MPPT
?
PV short-circuit current
15 A [1]
PV startup voltage
?

Efficiency and modes

Peak efficiency
97.6 % [2]
CEC weighted efficiency
97 % [1] [2]
Battery conversion efficiency
?
Grid / off-grid modes
?
Generator input
?
Transfer time
?
Idle consumption
0.05 W Needs confirmation [1]
Parallel units
?

Communication and environment

Communications
Power line communication (PLC) [1]
Operating temperature
-40 to 65 °C / -40 to 149 °F converted [2] [1]
Enclosure rating
NEMA type 6 [1] [2]
Operating noise
?

Mechanical

Dimensions
W 175 × H 212 × D 30.2 mm / W 6.89 × H 8.35 × D 1.19 in converted [1] [2]
Weight
1.08 kg / 2.38 lb converted Needs confirmation [1]

Installation (from the manual)

Protection

AC input breaker
?
AC output breaker
20 A maximum AC output over current protection device [1]
Battery fuse or breaker
?
PV disconnect
Integrated DC disconnect / integrated AC disconnect: the DC and AC connectors have been evaluated and approved for use as the load-break disconnect required by NEC 690 [1]

Clearances and orientation

Installation clearances
Allow a minimum of 1.9 cm (3/4") between the roof and the microinverter.; Allow 1.3 cm (1/2") between the back of the PV module and the top of the microinverter.; For vertical mount, maintain > 30 cm (12") clearance from the edges of the PV module. [1]
Mounting orientation
Horizontally, bracket side up or vertically; do not mount the microinverter upside down [1]

Grounding

Grounding and neutral-ground bonding
The DC circuit meets the requirements for ungrounded PV arrays in NEC.; Ground fault protection (GFP) is integrated into the class II double-insulated microinverter. [1]

Not in the manual: Torque, Conductors, Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

Enphase IQ7 Microinverter IQ7-60-2-US · IQ7-60-2-US

Warranty

Warranty term?
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?
CECVerified listed as of snapshot [3]

Documents and sources

  1. IQ7 Series Microinverters installation and operation manual Manufacturer installation manual (PDF) · Revision 10/30/2025 · Checked Sep 19, 2026 https://enphase.com/download/iq7-series-microinverters-installation-and-operation-manual
  2. IQ7 and IQ7+ Microinverters data sheet Manufacturer datasheet (PDF) · Revision 10/30/2025 · Checked Sep 19, 2026 https://enphase.com/download/iq7-and-iq7plus-microinverters-data-sheet
  3. CEC Grid Support Inverter Lists (solar and battery inverters), official spreadsheet (data unchanged since October 1, 2026; downloaded October 11, 2026) Government equipment list (spreadsheet) · Revision Data unchanged since October 1, 2026 · Revised Oct 1, 2026 · Checked Oct 10, 2026 https://solarequipment.energy.ca.gov/Home/DownloadtoExcel?filename=InvertersList

Unofficial reference. Information may be incorrect. This sheet aggregates the public sources listed above, much of it community-reported. It is not official manufacturer documentation, not an installation guide and not a compliance record. Community-reported values are checked against official manufacturer information before publication; we cannot guarantee accuracy or completeness. Do not rely on this sheet for installation, purchase or compliance decisions: always confirm every value with the manufacturer’s official documentation before buying, wiring or installing equipment. Charged Reviews accepts no responsibility for errors or omissions. Manufacturers can submit documents or corrections.

Page 2 of 2 · Charged Reviews LLC · chargedreviews.com/inverters/enphase-iq7-60-2-usSome links pay us a commission. That does not affect what we record.