About brandMicroinverters, home batteries and energy management systems.
SKU detail
locator: Manual section 5.2.1 title; data sheet first column heading
conditions: Enphase's own model number, printed as the title of section 5.2.1 of the IQ7 Series installation and operation manual (IOM-00028-1.0) and as the first column heading of the IQ7 and IQ7+ data sheet (DSH-00174-2.0), whose text layer letter-spaces it.
The DC circuit meets the requirements for ungrounded PV arrays in NEC.; Ground fault protection (GFP) is integrated into the class II double-insulated microinverter.
Printed as "The DC circuit meets the requirements for ungrounded PV arrays in NEC" and "Ground fault protection (GFP) is integrated into the class II double-insulated microinverter" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 34).
Where: PDF page 34, 5.2.1 IQ7-60-2-US Microinverter specifications, Features and specifications, "Grounding" row
The data sheet prints a different weight. Enphase's IQ7 Series manual prints 1.08 kg (2.38 lbs.) for the IQ7-60-2-US; the IQ7 and IQ7+ data sheet prints 1.1 kg (2.4 lb). The manual value is recorded as the higher-priority document.
Printed in the manual as "Weight 1.08 kg (2.38 lbs.)".
Where: Manual PDF page 33, Weight
Sources
1.1 kg
Printed as "Weight kg (lb) 1.1 (2.4)" in Enphase's IQ7 and IQ7+ data sheet DSH-00174-2.0.
Printed as "Peak output power VA 250" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 32). No duration is printed for this figure.
Where: PDF page 32, 5.2.1 IQ7-60-2-US Microinverter specifications, AC parameters, "Peak output power" row
Printed as "Nominal AC output voltage range2 240 VAC (single phase) 208 VAC (single phase)" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 32). Output voltage. Note 2 reads "Nominal Voltage Range can be extended if required by the utility."
Where: PDF page 32, 5.2.1 IQ7-60-2-US Microinverter specifications, AC parameters, "Nominal AC output voltage range" row
Allow a minimum of 1.9 cm (3/4") between the roof and the microinverter.; Allow 1.3 cm (1/2") between the back of the PV module and the top of the microinverter.; For vertical mount, maintain > 30 cm (12") clearance from the edges of the PV module.
Printed as "Allow a minimum of 1.9 cm (3/4") between the roof and the microinverter" and "allow 1.3 cm (1/2") between the back of the PV module" and "For vertical mount, maintain > 30 cm (12") clearance from the edges" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 18).
Where: PDF page 18, Step 3: Mount the microinverters
Integrated DC disconnect / integrated AC disconnect: the DC and AC connectors have been evaluated and approved for use as the load-break disconnect required by NEC 690
Printed as "Integrated DC disconnect/ Integrated AC disconnect" and "approved for use as the load-break disconnect required by NEC 690" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 34).
Where: PDF page 34, 5.2.1 IQ7-60-2-US Microinverter specifications, Features and specifications, "Integrated DC disconnect/ Integrated AC disconnect" row
Printed as "Communication Power line communication (PLC)" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 34).
Where: PDF page 34, 5.2.1 IQ7-60-2-US Microinverter specifications, Features and specifications, "Communication" row
60 Hz (nominal); extended frequency range 47 to 68 Hz
Printed as "Nominal frequency Hz 60" and "Extended frequency range Hz 47 68" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF pages 32 and 33).
Where: PDF pages 32 and 33, 5.2.1 IQ7-60-2-US Microinverter specifications, AC parameters, "Nominal frequency" and "Extended frequency range" rows
Printed as "Nominal AC output voltage range2 240 VAC (single phase) 208 VAC (single phase)" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 32).
Where: PDF page 32, 5.2.1 IQ7-60-2-US Microinverter specifications, AC parameters, "Nominal AC output voltage range" row
The data sheet prints a different maximum input voltage. Enphase's IQ7 Series manual (IOM-00028-1.0) prints a maximum input DC voltage of 48 V for the IQ7-60-2-US; the IQ7 and IQ7+ data sheet (DSH-00174-2.0) prints 50 V. The manual value is recorded as the higher-priority document.
Printed in the manual as "Maximum input DC voltage V 48"; the operating range is 16 to 48 V and the start voltage 22 to 48 V.
Where: Manual PDF page 32, DC Parameters, Maximum input DC voltage
Sources
50 V
Printed as "Maximum input DC voltage V 50 60" in Enphase's IQ7 and IQ7+ data sheet DSH-00174-2.0; 50 V is the IQ7-60-2-US column.
20 A maximum AC output over current protection device
Printed as "Maximum AC output over current protection device A 20" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 33).
Where: PDF page 33, 5.2.1 IQ7-60-2-US Microinverter specifications, AC parameters, "Maximum AC output over current protection device" row
The manual prints maximum continuous AC output power 240 VA (-40°F to +149°F) and peak output power 250 VA; the data sheet prints the same 240 VA and 250 VA.
Where: Manual PDF page 32, AC Parameters, Maximum continuous AC output power
The data sheet prints a different nighttime consumption. Enphase's IQ7 Series manual prints a night tare loss of 50 mW for the IQ7-60-2-US; the IQ7 and IQ7+ data sheet prints a nighttime power consumption of 60 mW for both models. The manual value is recorded as the higher-priority document.
Printed in the manual as "Night tare loss mW 50"; 50 mW is recorded as 0.05 W.
Where: Manual PDF page 33, Miscellaneous parameters, Night tare loss
Sources
Converted: 50 mW / 1000 = 0.05 W
0.06 W
Printed as "Nighttime power consumption mW 60" in Enphase's IQ7 and IQ7+ data sheet DSH-00174-2.0; 60 mW is 0.06 W.
Printed as "Operating voltage range V 16 48" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 32). DC input operating voltage range.
Where: PDF page 32, 5.2.1 IQ7-60-2-US Microinverter specifications, DC parameters, "Operating voltage range" row
The maker prints this output only as apparent power ("Maximum continuous AC output power (-40°F to
+149°F)
VA 240"), with no rating in W or kW, so the real power output stays unknown; the 240 VA figure is recorded under apparent power. Revised on 12 October 2026: this kilowatt field held 0.24 kVA; it is kept in this note.
Where: Manual PDF page 32, AC Parameters, Maximum continuous AC output power
Horizontally, bracket side up or vertically; do not mount the microinverter upside down
Printed as "Mount the microinverter horizontally, bracket side up or vertically" and "Do not mount the microinverter upside down" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 18).
Where: PDF page 18, Step 3: Mount the microinverters
Printed as "Maximum DC input short circuit current (module Isc) A 15" in the Enphase IQ7, IQ7+, IQ7X, and IQ7A Microinverters installation and operation manual (IOM-00028-1.0, September 2023) (PDF page 32).
Where: PDF page 32, 5.2.1 IQ7-60-2-US Microinverter specifications, DC parameters, "Maximum DC input short circuit current (module Isc)" row
240 V (211 to 264 V) or 208 V (183 to 229 V), single phase V
The manual prints the nominal AC output voltage range as 211 to 264 Vrms for 240 VAC (single phase) and 183 to 229 Vrms for 208 VAC (single phase); the data sheet prints the same ranges. The ranges are written here with "to".
Where: Manual PDF page 32, AC Parameters, Nominal AC output voltage range
Not statedMPPT trackersNot statedMPPT range27 to 37 V
AC output
240 VAC (single phase); 208 VAC (single phase)
Warranty
Not stated
Size
1.12 L* (Calculated from published dimensions)W: 175 × H: 212 × D: 30.2 mm / W: 6.89 × H: 8.35 × D: 1.19 inWeight1.08 kg / 2.38 lb
Evidence score
4/100Missing details10% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Warranty term needed; Battery conversion efficiency needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Idle consumption0.06 W3.5 / 10.0
0.06 W is the less favorable figure the maker's documents print, and it is scored because they disagree; it never sets or raises the bar. The bar is 0.021 W, the lowest documented for an inverter, printed by the maker: Enphase IQ8M Microinverter IQ8M-72-2-US
Printed in the manual as "Night tare loss mW 50"; 50 mW is recorded as 0.05 W.
The maker's documents disagree; the less favorable printed figure, 0.06 W, is scored. Warning: The data sheet prints a different nighttime consumption
Research pending, 0 points: Certificates, Warranty term, Battery conversion efficiency.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with every published inverter because its output is not documented. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
StandardEvidenceStatusSource
CECauthority listing reportedlisted as of snapshot[3]
Scope
equipment listing
Covered models
IQ7-60-2-US
Limitations
Model IQ7-60-2-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ7-60-2-US {208V}"; "IQ7-60-2-US {240V}", CEC listing date 2021-06-01. This is an equipment listing, not UL certification or complete-system approval.
Listed by Enphase under "Installation" for product media 26745.
Location: IQ7 Series Microinverters installation and operation manual
Retrieved Sep 19, 2026
Original Enphase PDF preserved byte for byte, taken from the download list Enphase publishes for its own IQ7 store page at https://enphase.com/store/microinverters/iq7-series/iq7-microinverter-mc4. It is a series document: it establishes what Enphase published for the IQ7 series on the access date, and it is attached only to catalog models whose own series code the document's title names. The revision is whatever was published at this URL on that date; no later revision was checked and no issuer record was read.
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Listed by Enphase under "Data sheets" for product media 26745.
Location: IQ7 and IQ7+ Microinverters data sheet
Retrieved Sep 19, 2026
Original Enphase PDF preserved byte for byte, taken from the download list Enphase publishes for its own IQ7 store page at https://enphase.com/store/microinverters/iq7-series/iq7-microinverter-mc4. It is a series document: it establishes what Enphase published for the IQ7 series on the access date, and it is attached only to catalog models whose own series code the document's title names. The revision is whatever was published at this URL on that date; no later revision was checked and no issuer record was read.
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
IQ7 Series Microinverters installation and operation manual
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Archived copy of a document published by Enphase Energy. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
No sourced accessories or replacement parts listed yet.
Model history
Model identity
Model
IQ7-60-2-US
Manufacturer SKU IQ7-60-2-US · US market
Observed Oct 11, 2026
CEC: claimed
Product / system scope unresolved. Model IQ7-60-2-US listed on the California Energy Commission Grid Support Solar Inverter List (data unchanged since October 1, 2026; downloaded October 11, 2026) under Enphase Energy, Inc., as "IQ7-60-2-US {208V}"; "IQ7-60-2-US {240V}", CEC listing date 2021-06-01. This is an equipment listing, not UL certification or complete-system approval.
note: No qualifying inverter certificate evidence recorded.
display note: Unknown
Sources: No source on record
key: warranty
label: Warranty term
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 30
weight: 30
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: efficiency
label: Battery conversion efficiency
value: Unknown
unit: Unknown
shown: Research pending
shown detail: Unknown
state: pending
points: 0
ceiling: 15
weight: 15
share: Unknown
covered: no
missing: yes
folded: yes
reason: undocumented
reason text: Not documented. Undisclosed data scores 0.
note: Not documented.
display note: Unknown
Sources: No source on record
key: idle
label: Idle consumption
value: 0.06
unit: Unknown
shown: 0.06 W
shown detail: Unknown
state: documented
points: 3.5
ceiling: 10
weight: 10
share: 35
covered: yes
missing: no
folded: no
reason: documents-disagree
reason text: The maker's documents disagree; the less favorable printed figure, 0.06 W, is scored. Warning: The data sheet prints a different nighttime consumption