ECO-WORTHY's own product data, captured 2026-10-27, prints SKU "GW-L03YTJUSKBJ6000W-1" for option "Default Title" (variant 46982734708985) of listing "ECO-WORTHY Liber 6kP Solar Off-grid Split-phase Inverter, 6kW 48Vdc to 120Vac/240Vac, 9kW@500V PV Input".
Printed as "18.7(Net weight)" in the ECO-INV-48V6000WES01 manual's parameter table; the table prints no unit on this value, and kilograms is the unit its other metric rows use.
The ECO-INV-48V6000WES01 manual's parameter table lists "MPPT Efficiency" and "Maximum Efficiency of Battery Inversion" and prints "99.9% 93%" in that order; 93% is the battery inversion figure. No test conditions are printed.
The ECO-INV-48V6000WES01 manual's parameter table lists "MPPT Efficiency" and "Maximum Efficiency of Battery Inversion" and prints "99.9% 93%" in that order; 93% is the battery inversion figure. No test conditions are printed.
Printed as "18.7(Net weight)" in the ECO-INV-48V6000WES01 manual's parameter table; the table prints no unit on this value, and kilograms is the unit its other metric rows use.
Linked from https://www.eco-worthy.com/products/eco-worthy-6kw-solar-off-grid-split-phase-aio-inverter-48vdc-to-240vac-9kw-500v-pv-input with link text "none".
Original manufacturer-hosted PDF preserved byte for byte, linked from the manufacturer's own product page for SKU GW-L03YTJUSKBJ6000W-1. The revision is whatever was published at this URL on the access date; no later revision was checked and no separate variant coverage is claimed beyond the page that linked it.
Archived copy of a document published by ECO-WORTHY. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
ECO-WORTHY solar powered off-grid split-phase inverter manual, model ECO-INV-48V6000WES01 (September 25, 2026 capture)OfficialECO-WORTHYOfficial user manual
Certificate & compliance claims (1)
FCC SDOC Part 15BManufacturer claim · equipment listingClaimedListed when checked
Printed in the "Certification" row of the ECO-INV-48V6000WES01 manual's parameter table as "UL 1741, CSA-C22.2 No.107.1-16, FCC SDOC Part 15B". No declaration of conformity document was read; recorded as the manufacturer's claim.
ECO-WORTHY's user manual for model ECO-INV-48V6000WES01 (Version A-1 V1.01), linked from the 6kW inverter page as "Eco-Worthy 6kw Split phase Alo Inverter User Manual" and captured on September 25, 2026. Its 2.6 Product Parameter Table prints labels and values as separate runs of text; each value is read in label order. Figures are manufacturer ratings, not test results.
Archived copies
Archived copy of a document published by ECO-WORTHY. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
ECO-WORTHY United States store home page (captured October 19, 2026)OfficialECO-WORTHYOfficial product page
Source details
Revision
Not stated
Revision date
Not stated
Archived copy captured on 2026-10-19.
Location: Store country and currency menu
Retrieved
The home page of ECO-WORTHY's own store www.eco-worthy.com, captured October 19, 2026 with the paced research fetcher. Its store menu shows "United States" and "USD $", and its regional stores are at ca., uk., de. and au.eco-worthy.com. Store statements, not independent tests.
Linked from https://www.eco-worthy.com/products/eco-worthy-6kw-solar-off-grid-split-phase-aio-inverter-48vdc-to-240vac-9kw-500v-pv-input with link text "none".
Original manufacturer-hosted PDF preserved byte for byte, linked from the manufacturer's own product page for SKU GW-L03YTJUSKBJ6000W-1. The revision is whatever was published at this URL on the access date; no later revision was checked and no separate variant coverage is claimed beyond the page that linked it.
Archived copy of a document published by ECO-WORTHY. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
ECO-WORTHY's own US product page for the 6kW solar off-grid split-phase AIO inverter (SKU GW-L03YTJUSKBJ6000W-1), captured on September 25, 2026. It links the split-phase off-grid inverter manual (model ECO-INV-48V6000WES01) and an SGS UL 1741 certificate. Figures are manufacturer ratings, not test results.
Archived copy of a document published by ECO-WORTHY. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
Archived copy of a document published by ECO-WORTHY. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
ECO-WORTHY solar powered off-grid split-phase inverter manual, model ECO-INV-48V6000WES01 (September 25, 2026 capture)
Archived copy of a document published by ECO-WORTHY. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
SGS certificate of compliance SGSNA/26/GZ/00196X, model ECO-INV-48V6000WES01 (September 25, 2026 capture)
Archived copy of a document published by ECO-WORTHY. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Warranty term needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
CertificatesUL 1741, Third Edition, Dated September 28, 2021 +2Claimed10.2 / 45.0
Manufacturer claim; issuer verification pending. Applies to the exact inverter.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 3.5 to 7 kW output band. · Method version 0.5
UL 1741, Third Edition, Dated September 28, 2021Product / system scope unresolvedClaimedListed when checked
SGS North America certificate of compliance SGSNA/26/GZ/00196X, effective June 1, 2026, model ECO-INV-48V6000WES01. The standard is recorded exactly as the certificate prints it. The certificate says it is valid when the product appears in the SGS directory, which was not checked. Read as ECO-WORTHY serves it on its 6kW inverter page, captured September 25, 2026.
CSA C22.2 No. 107.1:16 (reaffirmed 2021)Product / system scope unresolvedClaimedListed when checked
SGS North America certificate of compliance SGSNA/26/GZ/00196X, effective June 1, 2026, model ECO-INV-48V6000WES01. The standard is recorded exactly as the certificate prints it. The SGS directory was not checked. Read as ECO-WORTHY serves it on its 6kW inverter page, captured September 25, 2026.
FCC SDOC Part 15BProduct / system scope unresolvedClaimedListed when checked
Printed in the "Certification" row of the ECO-INV-48V6000WES01 manual's parameter table as "UL 1741, CSA-C22.2 No.107.1-16, FCC SDOC Part 15B". No declaration of conformity document was read; recorded as the manufacturer's claim.
FCC SDOC Part 15BManufacturer claim · equipment listingClaimedListed when checked
Printed in the "Certification" row of the ECO-INV-48V6000WES01 manual's parameter table as "UL 1741, CSA-C22.2 No.107.1-16, FCC SDOC Part 15B". No declaration of conformity document was read; recorded as the manufacturer's claim.
Manufacturer SKU GW-L03YTJUSKBJ6000W-1 · US market
Observed
UL 1741, Third Edition, Dated September 28, 2021: claimed
Product / system scope unresolved. SGS North America certificate of compliance SGSNA/26/GZ/00196X, effective June 1, 2026, model ECO-INV-48V6000WES01. The standard is recorded exactly as the certificate prints it. The certificate says it is valid when the product appears in the SGS directory, which was not checked. Read as ECO-WORTHY serves it on its 6kW inverter page, captured September 25, 2026.
Product / system scope unresolved. SGS North America certificate of compliance SGSNA/26/GZ/00196X, effective June 1, 2026, model ECO-INV-48V6000WES01. The standard is recorded exactly as the certificate prints it. The SGS directory was not checked. Read as ECO-WORTHY serves it on its 6kW inverter page, captured September 25, 2026.
Product / system scope unresolved. Printed in the "Certification" row of the ECO-INV-48V6000WES01 manual's parameter table as "UL 1741, CSA-C22.2 No.107.1-16, FCC SDOC Part 15B". No declaration of conformity document was read; recorded as the manufacturer's claim.