Model number as printed in the DMX Power CMW Series page tables and in the model list of the CMW Series Owner's Manual (64-0077 Rev A, August 2015) ("Table 5-1, CMW Series Specifications Model: CMW412 CMW1012 CMW1512").
Converted: 18.5 cm x 10 = 185 mm; 10.4 cm x 10 = 104 mm; 5.3 cm x 10 = 53 mm
Printed as "7.3 x 4.1 x 2.1” (18.5 x 10.4 x 5.3 cm)" in the CMW412 column (column 1 of 3) of the Inverter Size (L x W x H) row, in the axis order the row names (length, width, height); the centimeter figures are recorded in millimeters.
Read from the CMW412 column of Table 2-2 in the CMW Series Owner's Manual, the minimum DC wire size for rated use with the cable to the battery 5 feet or shorter; the table prints larger sizes for longer distances.
Printed as 400 W continuous on the DMX Power page row for the CMW412; the owner's manual prints 400 W in the CMW412 column (column 1 of 3) of the Continuous Power row. 400 W expressed in kW.
Location: Page Power & Output table; PDF page 28, CMW Series Owner's Manual specifications table, Continuous Power row
Converted
Battery operating voltage
10.5 to 15.5 V
Needs confirmation: DMX Power documents print two battery voltage ranges
The CMW Series Owner's Manual (64-0077 Rev A, August 2015) prints an input voltage of 10.5 to 15.5 VDC (shown); the DMX Power family page prints an operating range of 10 to 15 V for the CMW412.
Input voltage, printed as "10.5 - 15.5 VDC" in the DC Operation Voltage Range row, printed once for every model of the table. The DMX Power page prints a different value, kept as an alternative; the owner's manual value is shown.
10 to 15 V
Printed as 10 to 15 V in the Operating Range column of the DMX Power page row for the CMW412.
Converted: 18.5 cm x 10 = 185 mm; 10.4 cm x 10 = 104 mm; 5.3 cm x 10 = 53 mm
Printed as "7.3 x 4.1 x 2.1” (18.5 x 10.4 x 5.3 cm)" in the CMW412 column (column 1 of 3) of the Inverter Size (L x W x H) row, in the axis order the row names (length, width, height); the centimeter figures are recorded in millimeters.
Read from the CMW412 column of Table 2-2 in the CMW Series Owner's Manual, the minimum DC wire size for rated use with the cable to the battery 5 feet or shorter; the table prints larger sizes for longer distances.
The Regulatory Approval row as printed in the CMW Series Owner's Manual (64-0077 Rev A, August 2015) once for every model of the table. Manufacturer claims; no issuer directory was checked.
Read from the CMW412 row of Table 2-1 in the CMW Series Owner's Manual ("CMW412 Hex Cap screws 52 to 58 lbf-in (5.9 to 6.5 N-m) NA"); lbf-in is stored as in-lb.
Operating temperature, printed as "32°F to 104°F (0°C to 40°C)" in the Operating Temperature row, printed once for every model of the table; the Celsius figures are recorded.
Location: PDF page 28, CMW Series Owner's Manual specifications table, Operating Temperature row
Documented
Published claims and calculations, not independent test results.
Documents
2 on file
PDF
CMW Series Owner's Manual (64-0077 Rev A, August 2015) (November 2, 2026 capture)OfficialDMX PowerOfficial instruction manual
Source details
Revision
64-0077 Rev A
Revision date
Not stated
Linked from DMX Power's CMW Series page; captured 2026-11-02T07:19:42.978Z (archived copy).
Location: PDF page 16, Table 2-1; PDF page 18, Table 2-2; PDF page 28, Table 5-1, CMW Series Specifications
Retrieved
The CMW Series Owner's Manual (64-0077 Rev A, August 2015), the owner's and installation manual of the CMW412, CMW1012 and CMW1512, linked from DMX Power's CMW Series page and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 07:19:42.978 UTC). DMX Power bought the Magnum Energy, Dimensions and CSW product lines from Sensata Technologies in April 2025. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
DMX Power CMW Series inverter page (November 2, 2026 capture)OfficialDMX PowerOfficial product page
Source details
Revision
Not stated
Revision date
Not stated
DMX Power catalog page; captured 2026-11-02T06:15:12.342Z (archived copy).
Location: Models & Specifications tables
Retrieved
DMX Power's catalog page for the CMW Series inverters (formerly the Dimensions CMW Series), which marks every CMW code discontinued, fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:15:12.342 UTC). DMX Power bought the Magnum Energy, Dimensions and CSW product lines from Sensata Technologies in April 2025. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
CMW Series Owner's Manual (64-0077 Rev A, August 2015) (November 2, 2026 capture)
Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term1 year1.2 / 30.0
1 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
Printed as "Warranty One Year" in the specifications table of the CMW Series Owner's Manual (64-0077 Rev A, August 2015).
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5