Key specs

Units
SKU
12LP10
Official instruction manual
Sources

Model number as printed in the DMX Power LP Series page tables and in the model list of the 12LP10 Owner's Manual (Form 122202 Revision H) ("Models: 12LP10 12LP10H 12LP10HR").

Official product page: DMX Power LP Series inverter page (November 2, 2026 capture) Checked · Earlier documentOfficial instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: Page Models & Specifications tables; manual model list

Documented

Weight
9.07 kg20 lb converted
Converted: 20 lb x 0.45359237 kg/lb, rounded to 0.01 kg
Official instruction manual
Sources

Converted: 20 lb x 0.45359237 kg/lb, rounded to 0.01 kg

Unit weight, printed as 20 lb in the Weight (lbs.) row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Weight (lbs.) row

Converted

Output voltage distortion
<5%
Official instruction manual
Sources

Printed as "<5% THD" beside the output waveform in the Output Waveform row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Waveform row

Documented

AC voltage
120 V
Official instruction manual
Sources

Output voltage, printed as "120 +/- 5%" in the Output Voltage (VAC) row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Voltage (VAC) row

Documented

Installation clearances (manual)
At least ½” of clearance is required on all sides except the bottom.
Official instruction manual
Sources

Printed as "At least ½” of clearance is required on all sides except the bottom" in the 12LP10 Owner's Manual (Form 122202 Revision H).

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 10, Mount Inverter, Inverter Mounting Recommendations

Documented

Dimensions
9.18 L
Calculated: Enclosure volume: W × H × D ÷ 1,000,000
W: 228.6 × H: 91.4 × L: 439.4 mmW: 9 × H: 3.6 × L: 17.3 in convertedOfficial instruction manual
Sources

Converted: 17.3 x 9 x 3.6 in x 25.4 mm/in, rounded to 0.1 mm

Printed as "17.3 x 9.0 x 3.6" in the Dimensions (in inches) (LxWxH) row, in the axis order the row names (length, width, height); the inch figures are converted to millimeters.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Dimensions (in inches) (LxWxH) row

Calculated

Efficiency
82 %
Official instruction manual
Sources

Printed as "Up to 82%" in the Efficiency row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Efficiency row

Documented

AC frequency
60 Hz
Official instruction manual
Sources

Output frequency, printed as "60 +/- .05%" in the Output Frequency row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Frequency row

Documented

Output waveform
Pure sine wave
Official instruction manual
Sources

Printed as "Pure Sine" in the Output Waveform row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Waveform row

Documented

All specs16
Output voltage distortion
<5%
Official instruction manual
Sources

Printed as "<5% THD" beside the output waveform in the Output Waveform row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Waveform row

Documented

AC voltage
120 V
Official instruction manual
Sources

Output voltage, printed as "120 +/- 5%" in the Output Voltage (VAC) row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Voltage (VAC) row

Documented

Efficiency
82 %
Official instruction manual
Sources

Printed as "Up to 82%" in the Efficiency row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Efficiency row

Documented

AC frequency
60 Hz
Official instruction manual
Sources

Output frequency, printed as "60 +/- .05%" in the Output Frequency row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Frequency row

Documented

Output waveform
Pure sine wave
Official instruction manual
Sources

Printed as "Pure Sine" in the Output Waveform row.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Output Waveform row

Documented

Battery voltage
12 V
Official product page
Sources

Printed as 12 VDC in the DMX Power page's Charging table row for the 12LP10.

Official product page: DMX Power LP Series inverter page (November 2, 2026 capture) Checked · Earlier document

Location: Page Charging table, DC System column

Documented

Surge AC output
2,000 W
Official instruction manual
Sources

Peak power, printed as 2000 in the Peak Power (Watts) row; the manual names no surge duration.

Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Peak Power (Watts) row

Documented

Continuous output
1 kW
Converted: 1000 W / 1000 = 1 kW
Official instruction manual
Sources

Converted: 1000 W / 1000 = 1 kW

Printed as 1000 W continuous on the DMX Power page row for the 12LP10; the owner's manual prints 1000 in the Output Power (Watts Cont.) row. 1000 W expressed in kW.

Official product page: DMX Power LP Series inverter page (November 2, 2026 capture) Checked · Earlier documentOfficial instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier document

Location: Page Power & Output table; PDF page 6, 12LP10 Owner's Manual specifications table, Output Power (Watts Cont.) row

Converted

Battery operating voltage
10.5 to 16 V
Needs confirmation: DMX Power documents print two battery voltage ranges

The 12LP10 Owner's Manual (Form 122202 Revision H) prints an input voltage of 10.5 to 16 VDC (shown); the DMX Power family page prints an operating range of 10 to 16 V for the 12LP10.

Official instruction manual
Sources

Input voltage, printed as "10.5 – 16.0" VDC in the Input Voltage (VDC) row. The DMX Power page prints a different value, kept as an alternative; the owner's manual value is shown.

10 to 16 V

Printed as 10 to 16 V in the Operating Range column of the DMX Power page row for the 12LP10.

Official product page: DMX Power LP Series inverter page (November 2, 2026 capture) Checked · Earlier document
Official instruction manual: 12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture) Rev Form 122202 Revision H · Checked · Earlier documentOfficial product page: DMX Power LP Series inverter page (November 2, 2026 capture) Checked · Earlier document

Location: PDF page 6, 12LP10 Owner's Manual specifications table, Input Voltage (VDC) row

Documented

Published claims and calculations, not independent test results.

Documents

2 on file
  • PDF
    12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture)OfficialDMX PowerOfficial instruction manual
    Source details
    Revision
    Form 122202 Revision H
    Revision date
    Not stated

    Linked from DMX Power's LP Series page; captured 2026-11-02T07:32:23.744Z (archived copy).

    Location: PDF page 6, Table 1 Specifications; PDF page 11, Table 2 Cable Sizing

    Retrieved

    The 12LP10, 12LP10H and 12LP10HR Owner's Manual (Form 122202 Revision H), linked from DMX Power's LP Series page and fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 07:32:23.744 UTC). DMX Power bought the Magnum Energy, Dimensions and CSW product lines from Sensata Technologies in April 2025. Manufacturer claims, not independent tests.

    Archived copies

    Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

    Archived backup Form 122202 Revision H · 1.69 MB

    Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-12lp10-dc-to-ac-power-inverter-manual.pdf. Copyright and takedown

    Source first found
    This copy captured
    Archived
    File detailsOriginal source
    Pages
    21
    Embedded creation date
    Embedded modification date

    Embedded dates are file metadata, not independent proof of publication.

    SHA-256: b91c486314e257114bf7c702074c27170b31ca2688b4ea99b5bbc1535b0d0b13

    Open
  • WEB
    DMX Power LP Series inverter page (November 2, 2026 capture)OfficialDMX PowerOfficial product page
    Source details
    Revision
    Not stated
    Revision date
    Not stated

    DMX Power catalog page; captured 2026-11-02T06:10:58.935Z (archived copy).

    Location: Models & Specifications tables

    Retrieved

    DMX Power's catalog page for the LP Series inverters (formerly the Dimensions LP Series), fetched directly from dmx-power.com with the paced research fetcher on November 2, 2026 (robots.txt read first; request ended 06:10:58.935 UTC). DMX Power bought the Magnum Energy, Dimensions and CSW product lines from Sensata Technologies in April 2025. Manufacturer claims, not independent tests.

    Open

Archive and older revisions

Archive and older revisions0

Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.

Archived documents

12LP10 Owner's Manual (Form 122202 Revision H) (November 2, 2026 capture)

Archived copy of a document published by DMX Power. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email legal@chargedreviews.com.

Archived backup Form 122202 Revision H · 1.69 MB

Archived copy, unaltered, kept as a record of what DMX Power published. Original address: https://dmx-power.com/sites/default/files/product/manual/sensata-12lp10-dc-to-ac-power-inverter-manual.pdf. Copyright and takedown

Source first found
This copy captured
Archived
File detailsOriginal source
Pages
21
Embedded creation date
Embedded modification date

Embedded dates are file metadata, not independent proof of publication.

SHA-256: b91c486314e257114bf7c702074c27170b31ca2688b4ea99b5bbc1535b0d0b13

Submit a document

Warranty

Product warranty
5 years
Official product page
Sources

Printed as "5 yr Warranty" in the headline figures of the DMX Power LP Series page, for the family.

Official product page: DMX Power LP Series inverter page (November 2, 2026 capture) Checked · Earlier document

Location: Page headline figures

Documented

Sellers

No sellers found.

Report a missing or wrong seller

Price history

No seller price history.

Owner reviews

No reviews yet

Own one? A verified review needs a receipt and a serial number photo, and counts 19× in the owner rating.

Write a review

Evidence score

6/100Missing details30% documented

The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.

Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.

Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.

Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.

Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.

Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 0 to 1.5 kW output band. · Method version 0.5

How it works

Certificates

No certificates on file. Certificate guide

Parts and accessories

No sourced accessories or replacement parts listed yet.

Model history

Model identity

Model
12LP10

Manufacturer SKU 12LP10

No historical observations recorded yet.

Community discussions

No discussions linked yet. Search DIY Solar Forum

Recalls / legal notices

No recalls or legal notices on file; this is not a complete recall or court search. All notices · Report a notice

Something wrong that is not one of the values above?

Prices · price basis. * Calculated; estimates labeled. Value needs confirmation; select it for the reason.