About brandCreabest (CREABEST), with an office and warehouse in Wachtendonk, Germany, says it designs and manufactures its own LiFePO4 batteries and inverters for off-grid and motorhome use, and sells them through its own UK, German and French web stores.
SKU detail
locator: Store page SKU line and product data; manual cover and model table
warning:
detail: The manual prints NVC300010E01 as the EU model with a Schuko socket, and it is recorded as that edition. Creabest sells this SKU on its UK store page, and some of that page's photos show a British socket, which the manual assigns to the UK model NVC300010K01.
summary: Sold on a UK store with a British socket photo
conditions: Creabest's store page prints "SKU: NVC300010E01" for the only version it sells; the manual linked from it prints "NVC300010E01 (12V-230V-3KW-100A EU)" and lists NVC300010K01 as the UK version. Some of the page's photos show a British (BS 1363) output socket, which the manual assigns to NVC300010K01.
The manual prints "AC Output Voltage/Frequency 230 VAC / 50 Hz AC Output Waveform Sinewave (< 3%THD)" once for all columns, and setting F19 (230V Series Output Voltage Range) offers 240, 230 or 220 V, default 230 V. The store page prints "Voltage 12V to 220-240Vac".
Where: PDF page 32 (printed page 31), 7. Specifications, AC Output Voltage/Frequency, 12V 3000W column (NVC300010E01 / NVC300010K01); Unit Setting F19
<4.0 A DC no-load draw (inverter mode); <0.8 A DC (power saving mode)
Printed in amps DC in the 12 V column of "Nominal DC Input Voltage 12.5 VDC 25.0 VDC No Load battery draw (Inverter Mode) < 4.0 ADC < 1.9 ADC No Load Current (Power Saving Mode) < 0.8 ADC < 0.4 ADC DC Input Voltage operating range 10.5 - 16.5 VDC 21.0 - 33.0 VDC"; no figure in watts is printed.
Where: PDF page 32 (printed page 31), 7. Specifications, No Load battery draw; No Load Current (Power Saving Mode), 12V 3000W column (NVC300010E01 / NVC300010K01)
Sources
about 3.5 A
The store page prints "No-load consumption about 3,5 A".
The manual prints "Bulk Charge Current Range 10-80 A 25-100 A 10-50 A" (25 to 100 A in the 12 V 3000 W column) and setting F10 prints "12V/3000W Models: Selectable Ranges 100A, 80A, 60A, 40A, 25A (Default 100A)". The store page prints "Max. Charging Current 100 A" and also "Please note: Default charging current = 60 A.", which differs from the manual's default of 100 A.
Where: PDF page 32 (printed page 31), 7. Specifications, Running as Battery Charger, Bulk Charge Current Range, 12V 3000W column (NVC300010E01 / NVC300010K01); Unit Setting F10
Wired remote control display (RJ12); CAN-BUS port; USB program port (firmware only); battery temperature sensor port; ignition start port
The manual lists the front ports ("g Remote Port h Battery Temperature Sensor Port i lgnition Start Port J Program Port k CAN BUS Port") and prints "Remote Display Port RJ12 Inverter Mode Battery Voltage, DC Current, AC Output Power Charger Mode Charging Voltage, Charging Current, AC Input Power"; the store page includes a "Wired Remote Control Panel 7M".
Where: PDF page 7 (printed page 6), Main Unit Front; PDF page 13 (printed page 12); PDF page 32 (printed page 31), 7. Specifications, Remote PANEL Display, 12V 3000W column (NVC300010E01 / NVC300010K01)
The manual prints "AC Output Voltage/Frequency 230 VAC / 50 Hz AC Output Waveform Sinewave (< 3%THD)"; setting F18 lets the output be set to "50HZ or 60HZ" (default 50 Hz). The store page prints "Frequency 50Hz / 60Hz".
Where: PDF page 32 (printed page 31), 7. Specifications, AC Output Voltage/Frequency, 12V 3000W column (NVC300010E01 / NVC300010K01); Unit Setting F18
The manual prints "AC Output Voltage/Frequency 230 VAC / 50 Hz AC Output Waveform Sinewave (< 3%THD)"; the store page prints "Wave Type Pure Sine Wave".
Where: PDF page 32 (printed page 31), 7. Specifications, AC Output Waveform, 12V 3000W column (NVC300010E01 / NVC300010K01)
The manual prints "AC Output Voltage/Frequency 230 VAC / 50 Hz AC Output Waveform Sinewave (< 3%THD)"; the AC input and output hardwire terminals are one live (L), one neutral (N) and one ground (PE) each (PDF pages 16 and 17).
Where: PDF page 32 (printed page 31), 7. Specifications, AC Output Voltage/Frequency, 12V 3000W column (NVC300010E01 / NVC300010K01)
The store page prints a shorter transfer time. Creabest's store page says the UPS transfer happens in less than 20 ms; the manual linked from it prints <30 ms. The manual value is recorded.
The manual prints "AC Transfer Switch Transfer Time <30 ms Transfer Relay Rating 16 A AC Input Source Setting 10,13,16 A AC Output Hardwire (max.) 30 A AC Output Socket (max.) 16A-EU,13A-UK,10A-AU"; an upper bound.
Where: PDF page 32 (printed page 31), 7. Specifications, AC Transfer Switch, Transfer Time, 12V 3000W column (NVC300010E01 / NVC300010K01)
Sources
20 ms
The store page prints that the switch to inverter power on a grid failure "happens in less then 20 milliseconds" (an upper bound).
120mm² / AWG #4/0 (up to 5 feet, recommended); 150mm² / 300 kcmil (up to 7.5 feet); 200mm² / 400 kcmil (up to 10 feet) Check note
The included DC cables are thinner than the manual's minimum. Creabest's store page lists two 50 mm² DC cables in the box; the manual linked from the same page prints 120 mm² (AWG #4/0) as the thinnest DC input wire for the 12 V 3000 W model at up to 5 feet. Both are recorded as printed.
The manual's table "Model Thinnest DC Input Wires Gauge Used ≤5 feet (Recommended) ≤7.5 feet ≤10 feet" prints "12V 3000W series 120mm² / AWG #4/0 150mm² / 300 kcmil (MCM) 200mm² / 400 kcmil (MCM)"; copper, rated at least 105 °C.
Where: PDF page 10 (printed page 9), DC Input Cable, Thinnest DC Input Wires Gauge Used, 12V 3000W series
Sources
50 mm², 70 cm (cables included in the box)
The store page prints "With DC Cable Yes. 50 mm² / 70 cm / Continuous current ≥250 A" for the two DC cables it includes.
A 12 V battery system: the cover prints "NVC300010E01 (12V-230V-3KW-100A EU)" and the specification table heads the column "230VAC 12V Model"; the same table prints "Nominal DC Input Voltage 12.5 VDC 25.0 VDC No Load battery draw (Inverter Mode) < 4.0 ADC < 1.9 ADC No Load Current (Power Saving Mode) < 0.8 ADC < 0.4 ADC DC Input Voltage operating range 10.5 - 16.5 VDC 21.0 - 33.0 VDC" (12 V and 24 V columns), so the nominal DC input voltage is 12.5 V DC.
Where: Cover; PDF page 32 (printed page 31), 7. Specifications, Nominal DC Input Voltage, 12V 3000W column (NVC300010E01 / NVC300010K01)
6000 W peak in the manual's 12 V 3000 W column ("AC Output Power 2000 W 3000 W 3000W AC Output Current 8.7 A 13.0 A 13.0 A AC Surge Power (Peak) 4000 W 6000 W 6000 W"); no duration is printed. The store page prints "Peak Power 6000 W".
Where: PDF page 32 (printed page 31), 7. Specifications, AC Surge Power (Peak), 12V 3000W column (NVC300010E01 / NVC300010K01)
The manual prints "Model AC Input Circuit Breaker to serve the unit AC Input Wire 230VAC series 20A (maximum) 4mm²/#12AWG (minimum)"; it says to use the same wire size for the AC output hardwire.
Where: PDF page 12 (printed page 11), AC input wire table, 230VAC series
DC-rated fuse or circuit breaker, 400 A DC, on the DC positive line
The manual prints "DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required." and "Fuse/Circuit Breaker Rating 12V 2000W System 12V 3000W System 24V 3000W System 300Adc 400Adc 200Adc" (400 A DC for the 12 V 3000 W system).
Where: PDF page 10 (printed page 9), DC Fuse or Circuit Breaker, 12V 3000W System
The manual prints "AC Transfer Switch Transfer Time <30 ms Transfer Relay Rating 16 A AC Input Source Setting 10,13,16 A AC Output Hardwire (max.) 30 A AC Output Socket (max.) 16A-EU,13A-UK,10A-AU"; the AC input source setting limits the input to 10, 13 or 16 A.
Where: PDF page 32 (printed page 31), 7. Specifications, AC Transfer Switch, Transfer Relay Rating, 12V 3000W column (NVC300010E01 / NVC300010K01)
10.5 to 16.5 V DC in the 12 V column of "Nominal DC Input Voltage 12.5 VDC 25.0 VDC No Load battery draw (Inverter Mode) < 4.0 ADC < 1.9 ADC No Load Current (Power Saving Mode) < 0.8 ADC < 0.4 ADC DC Input Voltage operating range 10.5 - 16.5 VDC 21.0 - 33.0 VDC".
Where: PDF page 32 (printed page 31), 7. Specifications, DC Input Voltage operating range, 12V 3000W column (NVC300010E01 / NVC300010K01)
Built-in residual current device (RCD): rated current 16A, rated residual operating current 30mA, breaking time under 0.1 s (store page)
The manual's model table prints "Rated current: 16A Rated residual operating current: 30mA" for the RCD of every model; the store page prints "RCD parameters: Rated current: 16A Rated residual current: 30mA Breaking time: t<0.1s".
Where: PDF page 6 (printed page 5), 2. Product Description model table, RCD column; store page RCD parameters
The manual prints "AC Output Power 2000 W 3000 W 3000W AC Output Current 8.7 A 13.0 A 13.0 A AC Surge Power (Peak) 4000 W 6000 W 6000 W" (columns 12 V 2000 W, 12 V 3000 W, 24 V 3000 W); 3000 W in the 12 V 3000 W column is expressed in kW. The store page prints "Continuous Power 3000 W".
Where: PDF page 32 (printed page 31), 7. Specifications, Running as Inverter, AC Output Power, 12V 3000W column (NVC300010E01 / NVC300010K01)
13.0 A in the manual's 12 V 3000 W column ("AC Output Power 2000 W 3000 W 3000W AC Output Current 8.7 A 13.0 A 13.0 A AC Surge Power (Peak) 4000 W 6000 W 6000 W").
Where: PDF page 32 (printed page 31), 7. Specifications, AC Output Current, 12V 3000W column (NVC300010E01 / NVC300010K01)
3000 W in the manual's 12 V 3000 W column ("AC Output Power 2000 W 3000 W 3000W AC Output Current 8.7 A 13.0 A 13.0 A AC Surge Power (Peak) 4000 W 6000 W 6000 W").
Where: PDF page 32 (printed page 31), 7. Specifications, AC Output Power, 12V 3000W column (NVC300010E01 / NVC300010K01)
The manual prints two operating ranges. Its specification table prints 0 to 40 °C; its installation section says the environment temperature should be between -20 and 40 °C. The specification table value is recorded.
The manual's specification table prints "Operating Temperature 0℃ to 40℃ (32°F to 104°F)".
LVD: EN62477-1; EMC: EN61000-6-1, EN61000-6-3, EN61000-3-2, EN61000-3-3; CE marking. Store page: ECE R10 (E9*10R06/03*24568*00) certified
The manual's Safety and Environmental Conformance rows list LVD EN62477-1 and EMC EN61000-6-1, EN61000-6-3, EN61000-3-2 and EN61000-3-3, with CE as the agency marking; the store page's feature list prints "ECE R10 (E9*10R06/03*24568*00) certified". Claims in the maker's documents; no certificate was read.
Where: PDF page 33 (printed page 32), 7. Specifications, Safety and Environmental Conformance; Agency Markings, 12V 3000W column (NVC300010E01 / NVC300010K01); store page feature list
13.67 L* (Calculated from published dimensions)W: 287 × H: 110 × L: 432.9 mm / W: 11.3 × H: 4.33 × L: 17.04 inWeight7.4 kg / 16 lb
Evidence score
2/100Missing details30% documented
The Evidence score uses the priorities you choose. It counts published documents, such as certificates and warranty terms, and it compares a documented figure with the best documented figure of the same kind. It does not count owner reviews, and it is not a verdict on product quality or on how many people have reviewed it. A low score can mean little is documented, or that a documented figure is below the best of its kind. Undisclosed data scores 0.
Missing details. This number counts only the evidence recorded so far. The source review for this product is not finished, or the maker has not disclosed enough, so the number can only go up.
Missing for this product: Certificate evidence needed; Battery conversion efficiency needed; Idle consumption needed.
Each input is scored against the best documented value for an inverter: warranty term and battery conversion efficiency against every published inverter, idle consumption (lower is better) against the inverters in the same output band, or against every published inverter when the output is not documented. A documented value always earns points; an undisclosed one earns 0 and is listed as missing. Researched products receive a score. Certificates earn points for the evidence itself. Size and weight do not affect scores.
Warranty term2 years2.4 / 30.0
2 of 25 years, the best documented for an inverter (printed by the maker): APsystems DS3
The manual prints "Two-year Limited Warranty", covering manufacturing and material defects "for a period not exceeding two years from the date of sale to the original customer"; Creabest's store Warranty Policy prints "24 months quality guarantee" and excludes products bought from other retailers.
Research pending, 0 points: Certificates, Battery conversion efficiency, Idle consumption.
Warranty term and battery conversion efficiency are compared with every published inverter; idle consumption with the inverters in the same 1.5 to 3.5 kW output band. · Method version 0.5
What this shows: what each record says and how far it reaches. It does not mean the product is approved.
Unknown: no certification evidence recorded in this data.
Warranty
Field
Value
Conditions
Source
Warranty term
2 years
The manual prints "Two-year Limited Warranty", covering manufacturing and material defects "for a period not exceeding two years from the date of sale to the original customer"; Creabest's store Warranty Policy prints "24 months quality guarantee" and excludes products bought from other retailers.
Where: PDF page 33 (printed page 32), 8. Warranty; store Warranty Policy
Location: Cover; 2. Product Description model table (PDF page 6); installation sections (PDF pages 10 to 15); Unit Setting Function Chart (PDF pages 19 and 20); 7. Specifications (PDF pages 32 and 33); 8. Warranty (PDF page 33)
Retrieved Oct 16, 2026
User manual for the Inverter-Charger With RCD series (2000 W and 3000 W, 12 V and 24 V, EU and UK versions), file name Inverter-Charger_Manual-250527, served from Creabest's own Shopify file store (cdn.shopify.com/s/files/1/0778/4071/2014) and linked as "PDF Manual-Inverter with Charger & RCD 3000W" from the product's page on creabest.co.uk, captured on October 17, 2026. The manual itself does not print the Creabest name or any maker name; its provenance is that Creabest's own store page links it for this product. Its Specifications table (PDF pages 32 and 33) has a 12 V 2000 W, a 12 V 3000 W and a 24 V 3000 W column, with each EU (E01) model printed over its UK (K01) twin; only the 12 V 3000 W column (NVC300010E01 / NVC300010K01) is read, and a value printed once across the columns is read as printed. Manufacturer claims, not independent tests.
Archived copies
Archived copy of a document published by Creabest. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].
Creabest's own store-wide Warranty Policy page on creabest.co.uk, linked as "Warranty Policy" from every page of the store, captured on October 17, 2026. It names no product; it applies to purchases from Creabest and excludes products bought from other retailers.
Creabest's own UK store page for this product on creabest.co.uk (priced in GBP), captured on October 17, 2026; the content is whatever the address served on that date. It sells a single version (Shopify variant "Default Title") and prints "SKU: NVC300010E01"; its description table and RCD parameters are read. Some of its photos show a British (BS 1363) output socket, which the manual assigns to the UK model NVC300010K01. The page carries no revision date. Manufacturer claims, not independent tests.
Earlier revisions, archived captures and copies published by someone other than the manufacturer. Every one stays reachable.
Archived documents
Inverter-Charger With RCD User Manual, NVC200008E01/K01, NVC300010E01/K01, NVC300010E0124/K0124 (file Inverter-Charger_Manual-250527)
Archived copy of a document published by Creabest. Copyright retained by the publisher; kept for reference and verification only, no endorsement implied. To ask for its removal, email [email protected].